Iimveliso

  • I-GDP-713PM SF6 iGas Dew Point Tester (Indlela yeMirror eChilled)

    I-GDP-713PM SF6 iGas Dew Point Tester (Indlela yeMirror eChilled)

    GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester yenzelwe ngokukodwa i-SF6 igesi encinci yokubona ukufuma.Indibaniselwano egqibeleleyo yomgangatho ophezulu wenzwa yombethe kunye neteknoloji yokulawula i-elektroniki ehlakaniphile yenza ukuba isetyenziswe ngempumelelo kumlinganiselo ochanekileyo wendawo yombethe phantsi kweemeko ezahlukeneyo zokusingqongileyo.

    Umlinganiselo wamazolo usekelwe kumgaqo wesipili esibandayo.Umphunga wamanzi okwirhasi elinganisiweyo ujiyaniswa ube ngamanzi okanye kwiqabaka kumphezulu wesipili ngokusebenzisa i-semiconductor ebandayo yereactor yokupholisa.Xa ukulingana kwesigaba sesibini samanzi kwigesi kufikeleleke, ubushushu bomgangatho wesibuko bulinganiswa ngeli xesha, oko kukuthi indawo yombethe okanye iqabaka.

    Xa kuthelekiswa nolunye uhlobo lwemitha yokulinganisa umbethe, imitha yokulinganisa isibuko esipholileyo silinganisa ubushushu bendawo yombethe ngokuchanekileyo, kwaye kwangaxeshanye sineempawu zokuphindaphinda umlinganiselo omhle, iziphumo ezizinzileyo nezithembekileyo zokulinganisa, kunye nokusebenza ngokulula.

    I-GDP-713PM indlela yokupholisa ephathekayo ye-SF6 imitha yerhasi yombethe sisixhobo esisemgangathweni sokulinganisa ukufuma kwimimandla yamandla ombane, igesi, imozulu, i-elektroniki, i-petroleum, imboni yeekhemikhali, umlinganiselo, njl njl. Lukhetho olufanelekileyo lokuseka umgangatho wokufuma. isixhobo.

  • I-GDP-8000CM SF6 iGas Dew Point Tester (Indlela yeMirror eChilled)

    I-GDP-8000CM SF6 iGas Dew Point Tester (Indlela yeMirror eChilled)

    I-GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester yenzelwe ngokukodwa i-SF6 ukufuma kwerhasi encinci esetyenziswa kuyo yonke indawo yobushushu kushishino lwamandla, olusekwe kwisikhenkcisi saseStryn kunye nomgaqo wokulinganisa isipili esibandayo.

  • I-GDQC-55A SF6 i-Gas Vacuuming kunye nomatshini wokuzalisa

    I-GDQC-55A SF6 i-Gas Vacuuming kunye nomatshini wokuzalisa

    I-GDQC-55A SF6 i-Gas Vacuuming and Filling Machine isetyenziselwa ukufakela, ukusebenza, kunye nokugcinwa kwe-35kV ~ 220kV ikholomu ye-ceramic ye-SF6 izaphuli zesekethe, iziguquli kunye nezinye izixhobo zombane ze-SF6.Sisixhobo esixineneyo, esixhonywe kwisakhelo sentsimbi eyomeleleyo, kwaye sihambe ngokukhululekileyo nakwiindlela zegrabile.

    Ifanelekile kwizixhobo zombane ze-SF6, umenzi we-GIS kunye neziko lophando.

  • Inkqubo yoVavanyo lokukhupha inxalenye yeGIT series

    Inkqubo yoVavanyo lokukhupha inxalenye yeGIT series

    Uluhlu lwe-GIT lusetyenziswa ngokubanzi kumbane ophezulu, izixhobo zombane ezinkulu ze-GIS ezigqunyiweyo zokumelana novavanyo lombane, uvavanyo lokukhutshwa ngokuyinxenye kunye novavanyo lokuchaneka kwe-GIS yesiguquli, esilungele i-GIS substation, umenzi wezixhobo zamandla we-GIS, uhlobo lwesitya sombane somvelisi wombane.

     

     

     

     

     

     

  • I-GDSL-A I-Automatic 3-phase Primary Current Test Test Set with Temperature Test

    I-GDSL-A I-Automatic 3-phase Primary Current Test Test Set with Temperature Test

    I-GDSL-A Series 3-isigaba se-3 yesigaba sokuqala soVavanyo lweSitofu sangoku kunye noVavanyo loBubushushu sisixhobo esifanelekileyo sokuvavanya isixhobo sangoku kumashishini ombane kunye nombane, osetyenziswa kwizityalo zamandla, izikhululo zombane, ukuveliswa kombane kunye namaziko ophando, kunye neempawu. ubukhulu obuncinci, ubunzima obulula, ukusetyenziswa okulula kunye nokugcinwa.

     

     

     

     

     

  • I-GDCY Impulse Voltage Test System (100kV-7200kV)

    I-GDCY Impulse Voltage Test System (100kV-7200kV)

    Inkqubo yoVavanyo lwe-Impulse Voltage isetyenziselwa ukwenza uvavanyo olupheleleyo lwe-voltage yombane, ukusika uvavanyo lwempembelelo kunye nokutshintsha uvavanyo lwempembelelo kwizixhobo ze-HV ezifana neziguquli, isibambisi sotyando, izithinteli, iibhushi, ii-capacitors, kunye nokutshintsha.Inokuvelisa amaza ombane aqhelekileyo, amaza okutshintsha, amaza okusika kunye noluhlu olubanzi lwamandla kunye namandla.

     

     

     

  • Inkqubo yoVavanyo lokuKhupha ngokungaphelelanga kweGDYT uthotho

    Inkqubo yoVavanyo lokuKhupha ngokungaphelelanga kweGDYT uthotho

    Isetyenziswa ngokubanzi kwimveliso yombane, amasebe okusebenza kwamandla, amaziko ophando kunye neeyunivesithi.

     

     

     

  • Ibhentshi yoVavanyo lwe-GDBT-1000kVA

    Ibhentshi yoVavanyo lwe-GDBT-1000kVA

    Inkqubo yovavanyo ye-GDBT Transformer inokuqhuba zonke iimvavanyo zesiqhelo ze-transformer, kubandakanywa novavanyo lwe-No-load kunye nomthwalo, uvavanyo lwe-voltage ye-Induced, i-Power frequency ukumelana novavanyo lwe-voltage, uvavanyo lokukhupha inxalenye, uvavanyo lokumelana ne-DC, uvavanyo lomlinganiselo wokujika, uvavanyo lokunyuka kobushushu njl.

  • I-GDYB-S20 Inkqubo yoVavanyo lwemitha yeSigaba esiThathu

    I-GDYB-S20 Inkqubo yoVavanyo lwemitha yeSigaba esiThathu

    GDYB series Three Equal Potential Potential Multi-function Electric Energy Meter Test System iphuhliswe kakuhle kwisizukulwana sesithathu se-electronic programmable imitha yamandla ombane yesigaba sesithathu inkqubo yovavanyo olusebenzayo ngokwemigangatho nemimiselo yamva nje yesizwe.

     

  • GDHX-9500 Phase Detector

    GDHX-9500 Phase Detector

    I-GDHX-9500 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba kunye nesigaba sokulandelelana kolandelelwano kwi-substation, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa ukulandelelana kwesigaba.

  • GDHX-9700 Phase Detector

    GDHX-9700 Phase Detector

    I-GDHX-9700 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba, kunye nesigaba sokulandelelana kolandelelwano kwisitishi esingaphantsi, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa kokulandelelana kwesigaba.

  • I-GDND-800 yoMvavanyi weNdawo yokuQinisa

    I-GDND-800 yoMvavanyi weNdawo yokuQinisa

    Umvavanyi wendawo yokukhenkcisa ioyile yeTransformer ineempawu zoyilo olugqwesileyo lolwakhiwo kunye nenkqubo yokuvelisa eyodwa.Ihambelana ne-GB / T 3535 kunye nemigangatho ye-GB / T510 kwaye isetyenziselwa ukumisela indawo yokuthululela iimveliso zepetroleum.