I-GDSL-BX-200 Iseti yoVavanyo lwangoku lweSitofu, lusetyenziswa ikakhulu ekulinganiseni i-transformer yangoku, i-motor protector, i-air switch, i-switch cabinet, i-circuit breaker, isikrini sokukhusela kunye nokunye.
I-GDWR-5A i-Earth Resistance Tester sisixhobo sovavanyo oluchanekileyo oluphezulu olusetyenziswa kwiinkalo ezahlukeneyo ezifana nezitishi zokuvavanya ukumelana nomgangatho kunye neeparitha ezinxulumene nazo.Isixhobo sineempawu zomthamo omncinci, ubunzima obulula, ukuthwala okufanelekileyo, ukusebenza okunamandla okuchasana nokuphazamiseka kunye nokuchaneka okuphezulu.
I-GDJR-200D iSigaba esiSinye se-Electronic Thermal Relay Calibrator isetyenziselwa ukuseta kunye nokuqinisekiswa kwezixhobo zombane ezahlukeneyo.Ngeempawu zoyilo olufanelekileyo, ukusebenza ngokufanelekileyo kunye namandla amakhulu aphumayo, isetyenziswa kakhulu kwiindawo zovavanyo zombane zenkqubo yamandla, uloliwe, i-petrochemical, i-metallurgy kunye namashishini emigodi.
I-Power transformer winding deformation tester (indlela yokuphendula ngokuphindaphindiweyo) isekelwe kumlinganiselo wemilinganiselo yeempawu ze-transformer yangaphakathi, ithatha i-internal fault frequency analysis analysis (FRA), inokugweba ngokuchanekileyo iimpazamo zangaphakathi ze-transformers.
I-GD8000C ngokobungakanani benkqubo yokubeka iliso evuzayo kwi-intanethi isetyenziswa ikakhulu kwigumbi lokutshintshela i-35KV SF6 kunye ne-500KV, 220KV, 110KV igumbi le-GIS kwisikhululo esisezantsi ukujonga ukuvuza kwegesi ye-SF6 kwindawo ye-SF6 edityanisiweyo yezixhobo zombane kunye nomxholo weoksijini emoyeni ngexesha lokwenyani. .
Ngokuqhelekileyo kukho iindlela ezimbini zokubeka iliso kwimeko yokufakelwa kwezixhobo zombane eziphezulu kwizikhululo ezincinci: ukubeka iliso kwi-intanethi kunye nokuphila (okuphathekayo) kwi-intanethi.
I-GDFJ-311M SF6 Umvavanyi weMveliso yokuBoleka kweGesi sisixhobo esiphathwayo esenzelwe ukulinganisa imveliso yokubola kwegesi yeSF6.
I-high-voltage circuit breaker yenye yezona zixhobo zokulawula ezibalulekileyo kwinkqubo yamandla.
Umvavanyi we-GDRB-F Transformer winding deformation tester wamkela uhlahlelo lokuphendula ngokuphindaphindiweyo (SFRA) kunye nendlela yokuthintela ukufumanisa iintshukumo zomoya we-transformer kunye nokusilela koomatshini ngenxa yokothuka koomatshini, ukuthutha okanye iisekethe ezimfutshane, ezineempawu zesantya sovavanyo olukhawulezayo, uzinzo oluphezulu kunye nohlalutyo olunamandla. isoftware.
I-GDP-311IR SF6 umvavanyi wokucoceka kwerhasi sisixhobo esiphathwayo sovavanyo lokucoceka kwegesi kwindawo ye-SF6 ephuhliswe yinkampani yethu.