Inkqubo yoVavanyo lokuKhupha ngokungaphelelanga kothotho lwe-GDYT

Inkqubo yoVavanyo lokuKhupha ngokungaphelelanga kothotho lwe-GDYT

Ingcaciso emfutshane:

Isetyenziswa ngokubanzi kwimveliso yombane, amasebe okusebenza kwamandla, amaziko ophando kunye neeyunivesithi.

 

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

I-GDYT isetyenziselwa ubukhulu becala ukuvavanya inqanaba lokugquma kwamandla ombane wezinto ezahlukeneyo zokugquma, ulwakhiwo lokugquma kunye neemveliso zombane, nanjengoko kusenziwa ngokuyinxenye ukuvavanywa kobonelelo lwamandla ovavanyo lwezinto ezinje ngesiguquli, i-inductor ehambelanayo kunye nokubamba umbane.Isetyenziswa ngokubanzi kwimveliso yombane, amasebe okusebenza kwamandla, amaziko ophando kunye neeyunivesithi.

Ibandakanya amacandelo angezantsi
1. IYunithi yoLawulo loVavanyo lweHipot GDYD
2. I-PD-free uhlobo lwegesi ye-transformer YDQW
3. Ukudibanisa i-capacitor
4. Isixhasi esikhuselayo
5. Isihluzi sokuzihlukanisa LBQ
6. Umtshina wokukhupha inxalenye

Iimbonakalo

Advanced PD-free epoxy insulating ityhubhu, inxenye encinci yokukhupha umthamo.
Umbane ophantsi we-impedance, ungcono kunomgangatho wesizwe.
Itekhnoloji yokulawula ngokuzenzekelayo, ukusebenza kakuhle kokuchasana nokuphazamiseka.
Ukukhuselwa ngokukhawuleza kwe-elektroniki, ukuthembeka okuphezulu.

Iinkcukacha

Umthamo olinganiselweyo (KVA) : 5~5500
Umbane oPhezulu (KV): 50 ~ 250
Umbane ophantsi (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
Ikhava eliphezulu (mm): ngokuhambelana nemiqathango ethile

Umzekelo IkaliweUmthamo PhezuluI-Voltage PhantsiI-Voltage Ikhava ephezuluOD x Ukuphakama Ubunzima
(KVA) (KV) (KV) (mm) (IKG)
GDYT-5/50 5 50 0.22/0.38 320x450 42
GDYT-50/50 50 50 0.22/0.38 850x945 360
GDYT-10/100 10 I-100 0.22/0.38 570x725 150
GDYT-50/100 50 I-100 0.22/0.38 850x1000 400
GDYT-100/100 I-100 I-100 0.22/0.38 850x1000 800
GDYT-15/150 15 150 0.22/0.38 1165x1400 500
GDYT-75/150 75 150 0.22/0.38 1350x1570 1100
GDYT-150/150 150 150 0.38/0.6 1350x1570 1400
GDYT-20/200 20 200 0.22/0.38 1165x1850 760
GDYT-100/200 I-100 200 0.22/0.38 1450x1950 1800
GDYT-200/200 200 200 0.38/0.6 1800x1950 3100
GDYT-25/250 25 250 0.22/0.38 1250x2200 1250
GDYT-150/250 150 250 0.38/0.6 1450x2200 1900
GDYT-250/250 250 250 0.38/0.6 2000x2300 3100
GDYT-500/250 500 250 3/6 200x2600 5800
GDYT-1000/250 1000 250 3/6 2200x2600 8200