Iiseti zoVavanyo lwe-AC oluPhezulu lwe-GIS

Iiseti zoVavanyo lwe-AC oluPhezulu lwe-GIS

Ingcaciso emfutshane:

I-AC Resonant Test System ye-Substation Electrical Equipment, iqulunqwe ubukhulu becala unikezelo lombane oluguquguqukayo, i-Excitation Transformers, i-Reactors, i-Capacitive dividers, eyilelwe i-AC yokumelana novavanyo lwamandla ombane wesixhobo sombane esingaphantsi kwe-500kV okanye ngaphantsi.

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

Usetyenziso

Umtshintshi
Inkqubo yeGIS
SF6 isixhobo sokutshintsha
Iintambo
Bushing
Isigquduli
CT/PT
Ezinye izixhobo ze-capacitive

Iimbonakalo

Ubushushu obuncinci bukhuphuka kumthwalo olinganisiweyo.Izixhobo zombane ezomileyo okanye ze-oyile, amandla aphezulu omatshini, ukugquma okulungileyo, kuhle kwaye kuthembekile.
Umthamo ohlengahlengiswayo womthombo wolawulo lwamaza.Ukukhuselwa okuqinileyo, ukuzinza okulungileyo.Ngemowudi yokusebenza emininzi, kulula ukuyisebenzisa.
Ngamandla angama-220V okanye angama-380V wesigaba esinye, elungele ukufunwa kwamandla kwisiza.
Ubumbeko oluguquguqukayo.Ii-reactors zodidi ezahlukeneyo zokuzikhethela, zihlangabezana neemfuno ezahlukeneyo zovavanyo.Imisebenzi emininzi, enexabiso eliphantsi.

Iinkcukacha

Ilinganiswe i-voltage yemveliso: ngokusekelwe kwizinto ezahlukeneyo zokuvavanya.
Ubuninzi bemveliso: 20- 300Hz.
I-Waveform: i-sine wave ecocekileyo, iTHD <1.0%.
Max.umthamo: 1000kVA nangaphantsi.
Umjikelo woMsebenzi: Ixesha eliqhubekayo lokusebenza 15mins ngexesha elinye ekuphumeni kwamandla apheleleyo.(okanye imfuno yomthengi.)
Ukuziva ulungelelwaniso rhoqo: 0.1Hz, ukungazinzi <0.05%.
Unikezelo lwamandla: 380/220V ± 15%/50Hz ± 5%.

Uqwalaselo lweMveliso

GDTF-108/108

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-108

Umthamo (kVA)

108

Umda wosetyenziso

31500kVA okanye ngaphantsi

I-35kV isiguquli samandla

I-35kV i-circuit breaker kunye ne-bar yebhasi, i-insulators

10kV (300 mm²) intambo 2000m

35k V (300 mm²)intambo 500m

Ulungelelwaniso oluphambili

5kW Umthombo oguquguqukayo wamatyeli e-1 iseti

5kVA Isiguquli esichulumancisayo iseti e-1

I-reactors 27kV/1A 4sets

Isahluli esinamandla yi-100kV

GDTF-216/216

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-216

Umthamo (kVA)

216

Umda wosetyenziso

I-110kV I-Circuit breaker kunye nebha yebhasi

110kV GIS

35kV(300 mm²) intambo 1500m

10kV(300 mm²) intambo 3km

I-110kV yesiguquli sokugquma esigcweleyo

Ulungelelwaniso oluphambili

10kW Umthombo oguquguqukayo wamatyeli e-1 iseti

10kVA Isiguquli esichulumancisayo iseti e-1

I-reactors 54kV/1A 4sets

Isahluli esinamandla ngama-200kV

GDTF-270/270

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-270

Umthamo (kVA)

270

Umda wosetyenziso

I-110kV GIS kunye ne-transformer

I-110kV GIS kunye ne-transformer

35kV (300 mm²) intambo 2km

Ulungelelwaniso oluphambili

I-15kW Umthombo wamatyeli aguquguqukayo iseti e-1

15kVA Isiguquli esichulumancisayo iseti e-1

I-reactors 54kV/1A 5sets

Isahluli esinamandla yi-300kV

GDTF-400/400

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-400

Umthamo (kVA)

400

Umda wosetyenziso

I-220kV GIS kunye ne-transformer

10kV (300 mm²) intambo 4km

35kV (300 mm²) intambo ye-1km

Ulungelelwaniso oluphambili

20kW Umthombo wamatyeli aguquguqukayo iseti e-1

20kVA Isiguquli esichulumancisayo iseti e-1

I-Reactor
100kV/ 1 A 4sets

Isahluli esinamandla yi-400kV

GDTF-520/260

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-260

Umthamo (kVA)

520

Umda wosetyenziso

I-110KV i-Circuit breaker kunye nebha yebhasi

110kV GIS

110kV (300 mm²) intambo 800m

35kv (300 mm²) intambo 3km

10kV (300 mm²) intambo 6km

I-110kv isiguquli sokugquma esigcweleyo

Ulungelelwaniso oluphambili

25kW Umthombo wamatyeli aguquguqukayo iseti e-1

25kVA Isiguquli esichulumancisayo iseti e-1

I-Reactor 65kV/2A 4sets

Isahluli esinamandla yi-300kV

GDTF-500/500

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-500

Umthamo (kVA)

500

Umda wosetyenziso

220kV okanye ngaphantsi kwe-CT/PT

220kV okanye ngaphantsi kwehlathi

I-220kV okanye ngaphantsi kwe-Insulators, izixhumi

I-220kV okanye ngaphantsi kwe-Circuit breaker

I-220kV okanye ngaphantsi kwe-Insulation Instrument

Ulungelelwaniso oluphambili

20kW Umthombo wamatyeli aguquguqukayo iseti e-1

20kVA Isiguquli esichulumancisayo iseti e-1

IReactor 125kV/1A 4sets

Isahluli esinamandla yi-500kV

GDTF-600/600

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-600

Umthamo (kVA)

600

Umda wosetyenziso

110kV (300 mm²) intambo 800m

35kv (300 mm²) intambo 110m

I-35-220kV GIS, i-transformers, i-insulators

Ulungelelwaniso oluphambili

30kW Umthombo wamatyeli aguquguqukayo iseti e-1

30kVA Isiguquli esichulumancisayo iseti e-1

IReactor 120kV/1A 5sets

Isahluli esinamandla yi-600kV

GDTF-800/800

Umbane wokufaka (V)

380

Umbane ophumayo (kV)

0-800

Umthamo (kVA)

800

Umda wosetyenziso

110kV (300 mm²) intambo 800m

220kv (300 mm²) intambo 500m

I-35-500kV GIS, i-transformers, i-insulators

Ulungelelwaniso oluphambili

40kW Umthombo wamatyeli aguquguqukayo iseti e-1

40kVA Isiguquli esichulumancisayo iseti e-1

IReactor 200kV/1A 4sets

Isahluli esinamandla yi-800kV