info@hvhipot.com
English
CN
Ekhaya
Ngathi
HV HIPOT
Iqela
Imbeko kunye neMfaneleko
Umda woShishino
Umzi-mveliso wethu
Iimveliso
Izixhobo zoVavanyo lwe-Voltage High
Iseti yovavanyo lwe-AC Hipot
Iseti yovavanyo lwe-DC Hipot
Iseti yovavanyo lwe-AC DC yeHipot yoMdibaniso
Inkqubo yoVavanyo lwe-AC Resonant
Iseti yoVavanyo lwe-VLF AC Hipot
Inkqubo yoVavanyo lokukhutshwa kweCorona
Ukwahlula amandla ombane aphezulu
Jika-ukujika Surge Withstand Tester
IsiXhobo soMlinganiselo wokukhupha ngokuyinxenye
Isihlalutyi sokukhupha ngokuyinxenye
Isikhangeli sokukhupha ngokuyinxenye
Ukukhutshwa ngokuyinxenye kuVavanyo lwe-Intanethi
Impulse Voltage kunye neNkqubo yangoku yoVavanyo
Impulse Voltage Test System
Inkqubo yangoku yoVavanyo lweMpulse
Ukuqulunqwa kweNkqubo yoVavanyo lwamaza
Izixhobo zoVavanyo lweTransformer
ICapacitance yeTransformer kunye neTan Delta Tester
Transformer DC Winding Resistance Tester
Umthwalo weTransformer kwaye akukho Mvavanyo woLahleko loMthwalo
Transformer Oli BDV Tester
Transformer Oyile Tan Delta Tester
Ibhentshi yoVavanyo lweTransformer
ITransformer iJika iRetio Tester(TTR Tester)
Transformer Wining Deformation Tester
CT/PT Umlinganiselo kunye noHlalutyo
SF6 Ukufunyanwa kwegesi evuzayo kunye noHlahlelo
I-SF6 ye-Gas Density Relay Calibrator
I-SF6 iGesi evuza iGesi
SF6 Gas Online Monitoring Isixhobo
I-SF6 yoMhlalutyi woMgangatho weGesi
SF6 iGas Recycling System
Switch-gear Test Isixhobo
I-Circuit Breaker Analyzer
Qhagamshelana ne-Resistance Tester
DC Power Supply
Iseti yoVavanyo lwesitofu sangoku
Vacuum Switch Interrupter Vacuity Tester
iCable Fault yokuKhangela inkqubo
Ikhebula kunye neNdawo yombhobho
Inkqubo yeNdawo yeNkalo yeNtembu
Cable Test Van
IsiXhobo sokuBamba uMbane/Isixhobo soVavanyo lwe-Insulator
Umvavanyi we-Insulator
Lightning Arrester Online Test
Umvavanyi woMbane
Umtshina we-Ultrasonic
Relay Protection Tester
Digital Relay Tester
Universal Relay Tester
I-Insulation kunye ne-Earth Resistance Tester
Earth Resistance Tester
Uvavanyo lwe-Insulation Online
I-Insulation Resistance Tester
Umtshina weSigaba
Izixhobo zoVavanyo lwaMandla oMbane
I-Energy Meter Calibrator
Inkqubo yoVavanyo lwemitha yaMandla
Ukuhlaziywa koMgangatho wamandla
Isixhobo soVavanyo lwebhetri
AC kunye DC Power Supply
UkuTshaja ibhetri&Ukukhupha umvavanyi
Umvavanyi weBattery Impedance
Lead Acid Battery Regenerator
Izixhobo zoVavanyo lwe-oyile
IsiHlalutyi seChromatograph yegesi enyibilikileyo
Oli Acid Tester
Umatshini wokuHlunga i-oyile
Oli Flash Point Tester
I-Oli yokuQinisekisa indawo yoMvavanyi
Oli Tension Tester
Oli Trace ukufuma Tester
Isicelo
Ividiyo yokusebenza
Isikhokelo sobuGcisa
Izixhobo zoVavanyo lwe-Voltage High
Iinkonzo
OEM & Customization
Ezinye Iinkonzo ezisondeleleneyo
Iindaba
Imeko eqhelekileyo
Utyelelo loMthengi
Iindaba zeNkampani
Qhagamshelana nathi
Imeko eqhelekileyo
Ekhaya
Iindaba
Imeko eqhelekileyo
I-HV Hipot ibonelela abathengi baseShijiazhuang ngeenkonzo zokugunyazisa iiseti ezipheleleyo zezixhobo zokuvavanya iPD-Free
ngu admin on 22-09-22
Kutshanje, abasebenzi bobugcisa be-HV Hipot bamenywe eShijiazhuang, kwiPhondo laseHebei.Injongo yolu hambo ibikukubonelela umthengi ngeenkonzo zoqeqesho kunye nolungiso lweempazamo ze “GDYT-5kVA/50kV iseti epheleleyo yezixhobo zovavanyo -PD Mahala “....
Funda ngokugqithisileyo
I-HV Hipot iye e-Xiangyang ukuze ibonelele ngolungiso olwenziwayo lombane lwe-impulse kwiNkampani yokuBonelela ngoMbane iXiangyang
ngu admin on 22-08-24
Ngo-Agasti, iichwephesha zokuthengisa emva kwe-HV Hipot zaya e-Xiangyang.Injongo yolu hambo ibikukubonelela ngeenkonzo zokulungiswa kwamandla ombane kwi-Xiangyang Power Supply Company.Emva kokufika kwindawo, ngoncedo kunye nentsebenziswano yomthengi, ukufakwa kombane i ...
Funda ngokugqithisileyo
Abathengi be-Hebei bathenge ibhetshi yezixhobo zovavanyo lwe-voltage ephezulu kwi-HV HIPOT
ngu admin on 22-06-27
Kutshanje, abathengi be-Hebei bathenge ibhetshi yezixhobo zovavanyo lwe-voltage ephezulu kwinkampani yethu.Ukuza kuthi ga ngoku, lo myalelo wesithathu kubathengi abadala.Intsebenziswano eqhubekayo kunye nabathengi abadala ayinakwahlulwa kumgangatho wemveliso kunye nenkonzo egqibeleleyo emva kokuthengisa ye-HV Hipot.Izixhobo ziyathengwa...
Funda ngokugqithisileyo
Abathengi beJiangsu bathenge ibhetshi yezixhobo zovavanyo lwevoltage ephezulu kwinkampani yethu
ngu admin nge 22-06-20
Ekuqaleni kukaMeyi, abathengi baseJiangsu babenesidingo sokongeza izixhobo, ngoko banxibelelana neHV Hipot.Emva kwamaxesha amaninzi onxibelelwano kunye nabathengi, ukuqonda iimeko zesayithi zomthengi, izinto zokuvavanya kunye neeprojekthi zokuvavanya, i-HV Hipot "yenziwe" iseti yezixhobo ...
Funda ngokugqithisileyo
I-HV Hipot yamenywa eBeijing ukubonelela ngeenkonzo zokufakela kunye nokugunyazisa
ngu admin nge 22-03-30
Kutshanje, abasebenzi bobuchwephesha be-HV Hipot baye eBeijing ukuya kubonelela abathengi ngofakelo olufanelekileyo kunye neenkonzo zokugunyazisa ibhetshi "ye-insulation ephezulu yokumelana nezixhobo zovavanyo lombane".Emva kokuba amagcisa efikile kwi-c...
Funda ngokugqithisileyo
I-HV HIPOT ithumele ngempumelelo ibhetshi yezixhobo zovavanyo lokhuseleko eXinjiang
ngu admin on 21-11-08
Ekupheleni kuka-Okthobha, isebe lezentengiso linike ingxelo yokuba inkampani yetekhnoloji yamandla ombane eXinjiang ithenge ibhetshi yezixhobo zokuvavanya izixhobo zokhuseleko kwinkampani yethu.Izixhobo ezithengiweyo ngeli xesha zibandakanya: i-GDYD-D series AC Hipot tester, i-GDJS-6 i-series Insulated Glove (isihlangu ...
Funda ngokugqithisileyo
Yiya eKuwait ukuze ufumane isikhokelo sobugcisa kwisiza se-GDCY-20kV ijenereyitha yamandla ombane
ngu admin on 21-09-27
Ukususela nge-9 kaJulayi ukuya kwi-14 kaJulayi, iinjineli ze-HVHIPOT zaya e-Kuwait ukubonelela ngesikhokelo sobugcisa kwi-GDCY-20kV encinci ye-impulse voltage generator kubathengi.Ikomkhulu laseKuwait, isiXeko saseKuwait, yindawo...
Funda ngokugqithisileyo
I-VLF AC Hipot Test Set GDVLF-80 yavavanywa ngempumelelo eIndiya
ngu admin on 18-06-27
NgoJuni, ngo-2018, injineli yethu yaya e-Indiya ngokugunyazisa i-GDVLF-80 VLF AC Hipot Test Set.Uvavanyo lwathatha malunga neentsuku ezi-3.Sivavanye intambo yamandla ekhankanyiweyo ngokusekwe kwimfuno yovavanyo kwaye iphumelele ukwaneliseka ngumsebenzisi wokugqibela....
Funda ngokugqithisileyo
I-GDBT-1000KVA ibhentshi yokuvavanya i-transformer edibeneyo
ngu admin on 16-12-27
NgoDisemba ka-2016, i-HVHIPOT yamenywa ngumthengi waseKorea ukuba aqhube ukuthunyelwa kwisayithi kuyo.Ke inkampani yethu yalungiselela injineli yobuchwephesha ukuba iye eSouth Korea yodwa ukuze iqhubele umthengi ukulungisa ingxaki kwindawo.Imveliso elungisiweyo yomthengi yi-GDBT-10...
Funda ngokugqithisileyo
Ibhentshi yoVavanyo lweTransformer eKomishini eKorea
ngu admin on 16-12-27
Ngo-Dec., 2016, injineli ye-HV HIPOT izimisele ukuvavanya iBhentshi yoVavanyo yeTransformer eKorea.Indawo yovavanyo yi-KEPCO, eyona nto isetyenziswayo yombane inkulu eMzantsi Korea, inoxanduva lokuvelisa, ukuhanjiswa nokusasazwa kombane kunye nophuhliso lwe...
Funda ngokugqithisileyo
Thumela umyalezo wakho kuthi:
Bhala umyalezo wakho apha kwaye uwuthumele kuthi
Cofa u-enter ukukhangela okanye i-ESC ukuvala
English
French
German
Portuguese
Spanish
Russian
Japanese
Korean
Arabic
Irish
Greek
Turkish
Italian
Danish
Romanian
Indonesian
Czech
Afrikaans
Swedish
Polish
Basque
Catalan
Esperanto
Hindi
Lao
Albanian
Amharic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Bulgarian
Cebuano
Chichewa
Corsican
Croatian
Dutch
Estonian
Filipino
Finnish
Frisian
Galician
Georgian
Gujarati
Haitian
Hausa
Hawaiian
Hebrew
Hmong
Hungarian
Icelandic
Igbo
Javanese
Kannada
Kazakh
Khmer
Kurdish
Kyrgyz
Latin
Latvian
Lithuanian
Luxembou..
Macedonian
Malagasy
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Burmese
Nepali
Norwegian
Pashto
Persian
Punjabi
Serbian
Sesotho
Sinhala
Slovak
Slovenian
Somali
Samoan
Scots Gaelic
Shona
Sindhi
Sundanese
Swahili
Tajik
Tamil
Telugu
Thai
Ukrainian
Urdu
Uzbek
Vietnamese
Welsh
Xhosa
Yiddish
Yoruba
Zulu
Kinyarwanda
Tatar
Oriya
Turkmen
Uyghur