PD free Variable Frequency Test System

PD free Variable Frequency Test System

Ingcaciso emfutshane:

I-GDYT-350kVA/70kV PD free Resonant Test System yenziwe ngePD simahla unikezelo lwamandla ombane oguquguqukayo, ibhokisi yokulinganisa ye-HV, i-excitation transformer, isiguquli sokwahlula, i-Resonant reactor, kunye ne-capacitive voltage divider.

 

 

 

 

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

I-GDYT-350kVA/70kV PD free Resonant Test System yenziwe ngePD simahla unikezelo lwamandla ombane oguquguqukayo, ibhokisi yokulinganisa ye-HV, i-excitation transformer, isiguquli sokwahlula, i-Resonant reactor, kunye ne-capacitive voltage divider.
Le nkqubo yovavanyo ayinayo ingxaki yokuqalisa ngokugqithisileyo.Ukusebenzisa unikezelo lwamandla amancinci kunokugqiba uvavanyo olulingana namaxesha angama-30 ukuya kwangama-60 ombane, okunciphisa kakhulu ingxaki yokungonelanga kwamandla ombane wovavanyo lwentsimi.

Iimbonakalo

Ukhuseleko nokuthembeka.Inemisebenzi emininzi, kubandakanywa ukukhutshwa kunye nokukhusela ukuchithwa, ukukhuselwa kwe-voltage kunye ne-over-current setting, ukuvavanya amandla okukhusela, ukukhuselwa kwe-zero, ukukhuselwa kwe-heat-heat etc. ukuqinisekisa ukhuseleko lwabaqhubi, inkqubo yovavanyo kunye nento yokuvavanya.
Ukusebenza okulula kunye ne-wiring elula.
320 * 240 LCD umboniso, bonisa amandla ombane, imveliso yangoku, i-frequency, ubushushu bendalo, i-wave wave, umhla, ixesha njl.
Ukukhangela okuzenzekelayo kweresonant frequency, useto oluzenzekelayo lwefrikhwensi.
Uvavanyo lombane kunye nexesha linokusetwa.
Isiphumo somgangatho wokugqwethwa kwamaza we-sine wesekethe ye-HV ingaphantsi kune-1%, engenawo umonakalo ekuvavanyeni into.
Sebenzisa ngaphakathi okanye ngaphandle.Ngamagwegwe, alungele ukunyuselwa kwisiza.

Imeko yokusetyenziswa ngokubanzi

Ukuphakama: ≤ 3000m.
Ubushushu bendawo: -10℃ ukuya ku-40℃.
Ubushushu bokugcina: -20℃ ukuya ku-50℃
Amandla okukhanya kwelanga: 0.1W/cm2 (isantya somoya 0.5m/s)
Max.Umahluko wobushushu bemihla ngemihla: 25℃.
Ukusetyenziswa kwizinto ezingaqhubiyo luthuli, akukho-mlilo kwaye akukho luqhushumbo, indawo enomhlwa.
Sebenzisa ngaphandle okanye ngaphakathi.Ukugcinwa kwangaphakathi.
Itheminali yomgangatho othembekileyo kufuneka ifumaneke, ukumelana nomhlaba <0.5Ω
Umgangatho wofakelo lwe-reactor kufuneka ungabi ngaphezu kwe-5 °.