Iimpazamo, i-voltage, yangoku, amandla asebenzayo kunye asebenzayo, isigaba, i-frequency, kunye nemeko yamandla inokulinganiswa ngaxeshanye, kunye nomzobo we-vector kunye neziphumo zocingo ziya kuboniswa.
I-GDPQ-5000 yoMgangatho woMgangatho waMandla sisixhobo sovavanyo esibanzi esiphuhliswe ngononophelo yinkampani yethu kwaye yenzelwe ngokukodwa uvavanyo lwendawo yezigaba ezithathu, imisebenzi emininzi kunye nobukrelekrele, ukusebenza komatshini omfutshane womntu.
I-GDPQ-300E Ukuhlaziywa koMgangatho waMandla sisixhobo esiphathwayo sokuvavanya kunye nokuhlalutya umgangatho wokusebenza kwenkqubo yamandla.Ibeka iliso kwaye iqokelele idatha ngexesha elide, ikwabonelela ngohlalutyo lwe-harmonic kunye nohlalutyo lomgangatho wamandla.
Kwangaxeshanye uvavanye i-pulse echongiweyo emibini, kunye nemowudi eqhubekayo, yokusebenza kunye nenani lee-pulse ezichongiweyo ngexesha elinye linokwahluka ngokupheleleyo.
I-GDYM-1A Isigaba esinye se-Electric Energy Meter Calibrator sisixhobo sokulinganisa iiparamitha ezininzi esigcwele idijithali, i-mullti-function kunye nokuchaneka okuphezulu.
I-GDYB series Portable Electric Energy Test Meter Test System ilungele uvavanyo lwemitha yamandla ombane yesigaba sesithathu seklasi ye-0.2 nangaphantsi.Inenkangeleko entle, imisebenzi epheleleyo kunye nokusebenza okugqwesileyo.
GDYB series Single Equal Potential Multi-function Electric Energy Meter Test System iphuhliswe kakuhle kwisizukulwana sesithathu se-electronic programmable imitha yamandla ombane yesigaba sesithathu inkqubo yovavanyo esebenzayo ngokwemigangatho nemimiselo yamva nje yesizwe.
Uluhlu lwe-GDYB iSigaba esinye/eSithathu seSigaba soVavanyo lwemitha yeSigaba saMandla sisetyenziselwa ukulinganisa iintlobo ezahlukeneyo zeemitha zesigaba esinye/ezintathu ze-0.1% nangaphantsi.Inenkangeleko entle, imisebenzi epheleleyo kunye nokusebenza okugqwesileyo.
GDYB series Three Equal Potential Potential Multi-function Electric Energy Meter Test System iphuhliswe kakuhle kwisizukulwana sesithathu se-electronic programmable imitha yamandla ombane yesigaba sesithathu inkqubo yovavanyo olusebenzayo ngokwemigangatho nemimiselo yamva nje yesizwe.
I-GDPQ-300A Uhlalutyo lweMgangatho waMandla sisixhobo esiphathwayo sokuvavanya kunye nokuhlalutya umgangatho wokusebenza kwenkqubo yamandla.Ibeka iliso kwaye iqokelele idatha ngexesha elide, ikwabonelela ngohlalutyo lwe-harmonic kunye nohlalutyo lomgangatho wamandla.
I-GDDO-20C AC/DC Isixhobo sokuLungelela iimitha zoMbane isetyenziselwa ukukhangela impazamo esisiseko yezixhobo zombane ezahlukeneyo zombane kwiinkqubo zamandla, kubandakanywa i-voltmeter, i-ammeter, i-wattmeter, i-ohmmeter, isigaba esinye kunye nesigaba sesithathu seemitha zamandla e-AC (ukhetho) kunye nempazamo esisiseko DC volt-imitha kunye ammeter.