GDHX-9700 Phase Detector
I-GDHX-9700 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba, kunye nesigaba sokulandelelana kolandelelwano kwisitishi esingaphantsi, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa kokulandelelana kwesigaba.Isebenzisa ukhuseleko oluphindwe kabini kunye neesekethe ezintsha zedijithali, ezinokuphazamiseka okuchasene nokuphazamiseka, ngokuhambelana nemigangatho ye-EMC, ilungele iimeko ezahlukeneyo zokuphazamiseka kombane.
Umqondiso wesigaba sombane ophezulu wokukhokela okulinganisiweyo uya kuhanjiswa ngokuthe ngqo emva konyango, i-handset iya kufumana kwaye yenze uthelekiso lwesigaba, inqume iziphumo emva kokufunyanwa kwesigaba, umboniso wexesha langempela umehluko we-angle angle kunye ne-vector.Isebenzisa iteknoloji yothumelo engenazingcingo, ekhuselekileyo nethembekileyo, ekhawulezayo, kwaye ichanekile, ilungele ukusetyenziswa kumanqanaba ombane ahlukeneyo (10V-500KV).Xa uhlola isakhiwo segridi, inokuchonga ngokuchanekileyo isigaba esihambelanayo seendlela ezihlukeneyo zomgca odibeneyo wesigaba sesithathu, ngaphandle koxhumo lombane phakathi kwamacandelo amabini okulinganisa, okwenza ukusetyenziswa kwesixhobo sokulinganisa siguquguquke kakhulu kwaye sikhuselekile.
●Uluhlu lwamandla ombane: 10V ~ 500KV, olusebenzayo kumabakala ahlukeneyo ombane.
●Ukuchaneka: umgama omfutshane: impazamo ≤±3 °;umgama omde: impazamo ≤±3°.
●Ireyithi yesampulu: amaxesha ali-10 / ngomzuzwana.
●Umhla kunye nexesha lokumisela, umhla kunye nohlengahlengiso lwexesha, kulula kubasebenzisi ukukhangela, ukujonga idatha yembali.
●Ukusetha isibane sangasemva: ngokuqhelekileyo sivuliwe, ngokuqhelekileyo sivaliwe, umsebenzisi-uchazwe ngaphakathi kwe-0 ~ 999s.
●Ukuvalwa ngokuzenzekelayo: akunakuze, kuchazwe ngumsebenzisi ngaphakathi kwe-0 ~ 999 imizuzu.
●Kwinqanaba: ≤20 ° (umsebenzisi-uchazwe ukuba umda wesigaba ungaphakathi kwe-0-90 °, i-20 ° engagqibekanga)
●Inqanaba langaphandle: > 20 ° (umsebenzisi-uchazwe ukuba umda wesigaba ungaphakathi kwe-0-90 °, i-20 ° engagqibekanga)
●Umsebenzi wokulinganisa kwi-site: ukulinganisa kwisayithi kunokuqhutyelwa kwintambo evavanyiweyo ukuqinisekisa ukuchaneka kwe-angle yesigaba.
●Uyilo lwemowudi ezininzi, ukusetyenziswa okungcono, ukhuseleko ngakumbi, lulungele ngakumbi.
●Ujongano olulodwa lomatshini womntu, umsebenzi olula.
●Uyilo lwe-antenna yeFCC, umqondiso onamandla, kulula ukungena kwiindonga, iingcango, kunye nezithintelo.
●Ukukhusela kabini, ukuchasana okunamandla, ngokuthobela ngokupheleleyo imigangatho ye-EMC.
●Iitshathi kunye nomboniso wedatha, kulula ukufunda, kunye nomhla kunye nomsebenzi wokubonisa ixesha.
●Umlinganiselo womgangatho: umboniso ngophawu lwe-acousto-optic.
●Umlinganiselo wobungakanani: umboniso wexesha langempela lomahluko we-angle yesigaba, impazamo ≤5 °.
●Ukujonga ulandelelwano lwesigaba: ukulandelelana kwesigaba esilungileyo, ukulandelelana kwesigaba esibi (120 °, 240 °).
●Ngaphantsi kwenkonzo yexesha lesathelayithi yeGPS, umgama wokubona phakathi kwesixhobo sokubona iXa kunye neYa yi ≥500km.
●Umthamo wokugcina idatha wamaqela angama-2000.Iyakwazi ukubuza kunye nokufikelela kwidatha yembali.
●Ubude bentonga ye-insulation standard yi-4m, kwaye ibakala lombane elisebenzayo le-insulation rod ngu-≤ 220kV.
Uluhlu lwamandla ombane | 10V~500kV |
Ukunikezwa Amandla | Hkunye neyunithi ebanjwe: ibhetri enkulu ye-lithium |
Xa & Ya detector:Ubungakanani bebhetri yealkaline yeAA (1.5V) 3pcs | |
Ukuhanjiswa okungenazingcingo | Umgama obonakalayo 150m |
Kwinqanaba | ≤20 ° (umsebenzisi-uchazwe ukuba umda wesigaba ungaphakathi kwe-0-90 °) |
Isigaba sangaphandle | >I-20 ° (umsebenzisi-uchazwe ukuba umda wesigaba ungaphakathi kwe-0-90 °) |
Bonisa ukuchaneka | Umlinganiselo wobungakanani ≤5 ° |
Isisombululo se-angle yesigaba | 1° |
Umlinganiselo wolandelelwano lwesigaba | Ulandelelwano lwenqanaba lumiselwa nge-clockwise 120°/ counterclockwise 240° |
Uluhlu lwexesha lesathelayithi | 2 ~ 30 imizuzu |
Bonisa | Isikrini se-LCD esilungileyo, esicacileyo ekukhanyeni kwelanga. |
Ubushushu bokusebenza | -35~+50℃ |
Ubushushu bokugcina | -40~+55℃ |
Ubuntu bezizalwane | ≤95%RH, ukujiya |
Iyunithi ebanjwe ngesandla | 0.31 kg |
Umtshini Xa | 0.16 kg |
Umtshini uYa | 0.16 kg |