Ibhentshi yoVavanyo lwe-GDBT-1000kVA

Ibhentshi yoVavanyo lwe-GDBT-1000kVA

Ingcaciso emfutshane:

 

 GInkqubo yoVavanyo ye-DBT Transformer inokuqhuba zonke iimvavanyo zesiqhelo ze-transformer, kubandakanywa novavanyo lokungathwali kunye nomthwalo, uvavanyo lombane olunyanzelwayo, ukuvavanywa kwamandla ombane, ukuvavanywa kwe-voltage, uvavanyo lokukhupha, uvavanyo lokumelana ne-DC, uvavanyo lokulinganisa ukuguquka, uvavanyo lokunyuka kobushushu njl.

 

 

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

GDBT Transformer Test System(3)
Iinkcukacha zajikelele

Into yoVavanyo:
22.9kV iziguquli zeSigaba esinye kunye neziguquli ezikhethekileyo,umbane womthwalo kunye nokhoyo: AC 0-650V/78A, AC 0-1200V/29A, AC 0-2400V/14.6A
I-imedance ye-transformer evavanyiweyo ingaphakathi kwe-7%, icala le-HV yi-23kV, 11kV, 6kV.Icala le-LV yi-0.05kV-2.4kV.

Le bhentshi yovavanyo inokuqhuba uvavanyo olungezantsi:
1. Uvavanyo olungenamthwalo olubandakanya ukulahleka komthwalo, ipesenti yokungabikho komthwalo wangoku ukuya kwi-rated current.
2. Uvavanyo lomthwalo olubandakanya ukulahleka komthwalo, ipesenti ye-impedance voltage, ukuguqulwa kweqondo lokushisa ngokuzenzekelayo kunye novavanyo lokulahlekelwa ngumthwalo phantsi kwe-30% okanye ngaphezulu kwangoku ngokupheleleyo.
3. Uvavanyo lombane olwenziwayo.

Iimbonakalo

Idatha yovavanyo lwerekhodi yokwenziwa ngesandla kwaye uyigcine kuvimba weenkcukacha.
Idatha yovavanyo lwe-No-load inokulungiswa nge-waveform kunye ne-voltage elinganisiweyo ngokuzenzekelayo.
Idatha yovavanyo lomthwalo inokulungiswa ngeqondo lokushisa (75 ℃, 100 ℃, 120 ℃, 145 ℃) kwaye ireyithwe ngoku.
Kuvavanyo lwe-No-load, i-voltage yecala le-LV inokujongwa.
Kuvavanyo lomthwalo, icala le-HV langoku linokujongwa.
Yonke imisebenzi yovavanyo kunye nenkqubo yovavanyo inokukhethwa kwaye ilawulwe ngamaqhosha ephaneli yangaphambili.
Zonke iziphumo zovavanyo zilungiswa ngokwemfuno ye-GB1094, IEC60076 okanye i-ANSI C57.
Inkqubo yovavanyo inokuqhutywa ngesoftware yePC.
Yonke idatha inokugcinwa kwaye iprintwe.
Ngokhuseleko lwe-zero, ukhuseleko lwangoku kunye nemisebenzi yokukhusela i-voltage.
CT/PT uluhlu lokutshintsha ngokuzenzekelayo.
Ibhentshi yokuvavanya iya kulawula ngokupheleleyo kwisiphaluka sonke se-loop kwaye ibeke iliso kumlinganiselo.
Inkqubo ye-alam yokhuseleko.

Iinkcukacha

I-Transformer Load kunye ne-No-load Tester (Ekuphela kwereferensi, imodeli yokugqibela yiFluke Norma 4000)

Uluhlu lombane: 0-1000V
Uluhlu lwangoku: 0.25-20A, ukuchaneka kwe-0.2%.
Ukuchaneka kwamandla 0.3%.
I-Power factor 0.050-1.000, ukuchaneka kwe-0.3%
Ukuphindaphinda kwe-40-70Hz, ukuchaneka kwe-0.1%.
Amandla P
Akukho mthwalo wangoku Io, %
Akukho-mthwalo ilahleko Po
Umthwalo womthwalo wePk
I-impedance yamandla ombane Uk
Amandla Po
Umndilili wombane womgca we-Un
Umndilili wangoku kwi.

Iimpawu zeHV CT
Uluhlu lwamandla: 3kV
Uluhlu lokulinganisa: 0.25A-110A
Ukuchaneka 0.05%
Umlinganiselo wokujika yi-100,50,30,20,10,5,2.5/1A
 
PT iinkcukacha
Uluhlu lwamandla: 0.1kV-3kV(50Hz-400Hz)
Ukuchaneka 0.05%
Umlinganiselo wokujika yi-3,2,1,0.5kV/0.1kV

Unikezelo lwaMandla oMbane oGuquguqukayo
Igalelo lombane: Isigaba esinye AC380V, 60Hz
Uluhlu lokulinganisa: 0-800V
Umthamo olinganisiweyo: 30kVA
Imveliso yangoku: 0-37.5A
Ubuninzi bemveliso: 180Hz, 240Hz, 400Hz±2%

Isiguquli esiPhakathi
Umthamo: 40kVA
Igalelo lombane: Isigaba esinye 500V
Umbane ophumayo: 0-650V-1200V-2400V

I-100kVA yoLawulo lweSigaba esinye
I-voltage yokufaka: Isigaba esisodwa se-380V / 60Hz, i-voltage ephumayo 20-650V.
Max.Umthwalo wangoku: 154A
Ayingonxibelelwano olulawulayo, kulula ukuyisebenzisa.
Xa igalelo lombane lihlala lihleli, liyakwazi ukulungelelanisa i-voltage ephumayo kakuhle ngomthwalo.Yenziwe ngokukalwa rhoqo 60Hz.

Imfuneko yoyilo

Zonke iimvavanyo ezifunekayo zixhotyiswe kwibhentshi enye, umsebenzi ngamnye uzimele.Lonke uvavanyo luzenzekelayo.
UVavanyo lweMpawu yoMguquli (Akukho mthwalo kunye noVavanyo loMlayisho)
Ilawulwa yi-PC kwaye inikwe i-voltage induced regulator 100kVA, i-transformer ephakathi kwe-40kVA.

Sinokwenza iimodeli ezahlukeneyo zokukala ngokusekwe kwimfuno yokwenyani.

Ulwazi lweNkampani

GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester8
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester9
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester10
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester11