I-GDRB-F yoMvavanyi woGuquko oPhetheyo lwe-GDRB-F (i-SFRA kunye neNdlela yokuKhusela)
●Ukufumana kunye nokulawula usebenzisa i-high-speed, i-microprocessor edibeneyo kakhulu.
●Unxibelelwano lwe-USB interface esetyenziswa phakathi kwelaptop kunye nesixhobo.
●I-Hardware yamkela itekhnoloji ezinikeleyo ye-DDS yedijithali yesantya esiphezulu sokuskena (i-USA), enokuthi ichaze ngokuchanekileyo iziphene ezinje ngokujija okugqwethiweyo, ukugobhoza, ukuguquka, ukuthambeka, ukujika kotshintsho lwesekethe emfutshane kunye nesigaba esifutshane soqhagamshelwano.
●Isantya esiphezulu se-double-channel 16-bit A/D isampuli (kuvavanyo lwasendle, hambisa itephu itshintshi, kunye nejiko lamaza libonisa utshintsho olucacileyo).
●Ubungakanani bemveliso yesignali buhlengahlengiswa yisoftware, kwaye ixabiso lencopho le-amplitude yi-± 10V.
●Ikhompyutha iya kuhlalutya iziphumo zovavanyo ngokuzenzekelayo ize ivelise amaxwebhu ekhompyutha (iWord).
●Isixhobo sinezinto ezimbini zokulinganisa: umlinganiselo wokuskena oqhelekileyo kunye nesegment frequency scanning measurement, ehambelana nemo yokulinganisa amaqela amabini obugcisa eChina.
●Iimpawu ze-amplitude-frequency zihambelana neenkcukacha zobugcisa besizwe kwi-amplitude-frequency features tester.Ulungelelwaniso lwe-X (i-frequency) lunesalathisi somgca kunye nesalathiso se-logarithmic, ngoko ke umsebenzisi unokushicilela ijika ngesalathiso somgca kunye nesalathiso se-logarithmic.Umsebenzisi unokukhetha nokuba ngokweemfuno zangempela.
●Inkqubo yohlalutyo lwedatha yovavanyo oluzenzekelayo.
Uthelekiso oluthe tyaba lokufana okujikelezayo phakathi kwezigaba ezithathu A, B kunye no-C
Iziphumo zezi zilandelayo:
① Ukungaguquguquki okugqwesileyo
② Ukungaguquguquki kakuhle
③ Ukungaguquguquki kakubi
④ Ukungaguquguquki okubi
Ukuthelekisa ixesha elide iAA, BB, CC ibiza idatha yoqobo kunye nedatha yangoku kwisigaba esifanayo sokuthelekisa i-deformation yomoya.
Iziphumo zohlalutyo zezi:
① Ukujija okuqhelekileyo
② Ukuguqulwa okuncinci
③ Utshintsho oluphakathi
④ Utshintsho olumandla
●Uxwebhu lwe-elektroniki lwe-Word lunokwenziwa ngokuzenzekelayo ukuze lugcinwe kwaye luprintwe.
●Isixhobo sinokuhlangabezana ngokupheleleyo neemfuno zobugcisa bomgangatho wombane we-DL/T911-2004 "Uhlalutyo lokuphendula ngokuphindaphindiweyo kwi-deformation ejikelezayo yeenguqu zamandla".
●I-transformer winding deformation tester yenziwe yinxalenye yomlinganiselo kunye nenxalenye yesoftware yohlalutyo.Inxalenye yokulinganisa ilawulwa yi-high-speed single-chip microcomputer, kwaye iqulunqwe ukuveliswa komqondiso kunye nokulinganisa umqondiso.Inxalenye yokulinganisa isebenzisa ujongano lwe-USB ukudibanisa nethebhulethi okanye ilaptop.
●Kwinkqubo yokuvavanya, kuphela ibhasi yokudibanisa ye-transformer kufuneka isuswe, kwaye zonke iimvavanyo zingagqitywa ngaphandle kokuxhoma ikhava kunye nokuqhaqha i-transformer.
●Isixhobo sinoluhlu lwemisebenzi yokulinganisa i-frequency ye-frequency ye-frequency tshayela umlinganiselo we-frequency, i-linear frequency yokutshayela ukulinganisa i-frequency scan frequency ukuya kuthi ga kwi-10MHz, i-frequency scan interval inokwahlulwa ibe yi-0.25kHz, 0.5kHz kunye ne-1kHz, ukunika uhlalutyo ngakumbi lwe-transformer. deformation.
●Isixhobo sikrelekrele kakhulu, kulula ukusisebenzisa, kwaye sinemisebenzi emininzi efana nohlengahlengiso oluzenzekelayo loluhlu kunye nohlengahlengiso oluzenzekelayo lwesampulu.
●I-software ithatha iqonga windows, iyahambelana windows98/2000/winXP/Windows7 inkqubo.Nikeza abasebenzisi ngojongano olulula ngakumbi nolusebenziseka lula.
●Ukubonelela ngohlalutyo lothelekiso lwegophe lwembali, lunokulayisha uqwalaselo oluninzi lwembali ngexesha elinye, lunokukhetha ngokuthe ngqo naliphi na igophe lohlalutyo oluthe tye kunye noluthe nkqo.Ixhotyiswe ngenkqubo yokuhlalutya okukrelekrele kunye nenkqubo yokuxilongwa, iyakwazi ukuxilonga ngokuzenzekelayo imeko ye-transformer windings, ilayishe ii-curves ezi-6 ngaxeshanye, kwaye ibale ngokuzenzekelayo iiparitha ezifanelekileyo zegophe ngalinye, ihlolisise ngokuzenzekelayo ukuguqulwa kwee-windings, kwaye inike isiphelo reference reference.
●Umsebenzi wolawulo wesoftware onamandla, uqwalasela ngokupheleleyo iimfuno zokusetyenziswa kwendawo, kwaye ugcina ngokuzenzekelayo iiparamitha zemeko yokusingqongileyo ukubonelela ngesiseko soxilongo lokuguquguquka kokuguquguquka.Idatha yokulinganisa igcinwa ngokuzenzekelayo kwaye inomsebenzi wokushicilela umbala, olungele abasebenzisi ukuba bakhuphe iingxelo zovavanyo.
●Isoftware ineempawu ezicacileyo zokusebenzisa umsebenzisi.Uninzi lweemeko zokulinganisa zizinto ozikhethelayo.Iiparamitha ezicacileyo ze-transformer zingagcinwa kwireferensi yokuxilongwa, kwaye akukho mfuneko yokungena kwisayithi, kwaye umsebenzisi unokongeza kwaye aguqule ulwazi kamva, olulungele ngakumbi ukuyisebenzisa.
●Isoftware inenqanaba eliphezulu lobukrelekrele.Emva kokuba igalelo kunye neziphumo zezibonakaliso zixhunyiwe kwaye iiparitha zeemeko zisetiwe, yonke imisebenzi yokulinganisa inokugqitywa, kwaye i-curve waveform yembali inokuvulwa kumlinganiselo nanini na ukujongwa ngokuthelekisayo kunye nokuyeka ukulinganisa.
●Ixesha elifunekayo kumlinganiselo wesigaba ngasinye lingaphantsi kwemizuzwana engama-60.Ixesha elipheleleyo lokulinganisa ukuguqulwa kwe-winding ye-transformer yamandla ene-windings ephezulu, ephakathi kunye nephantsi (umthamo kunye nenqanaba lombane alikhawulelwanga) lingaphantsi kwemizuzu eyi-10.
●Xa ulinganisa i-transformer, abasebenzi be-wiring banokubeka ngokungqongqo igalelo lesiginali kunye nokukhokelela ekuphumeni, okungenayo impembelelo kwiziphumo zokulinganisa.Abasebenzi be-wiring banokuhlala kwitanki ye-transformer ngaphandle kokuhla, ukunciphisa ubuninzi bomsebenzi.
Imowudi yokuskena:
1. Unikezelo lokuskena ngomgca
Uluhlu lokulinganisa ukuskena: (10Hz) - (10MHz) 40000 indawo yokuskena, isisombululo 0.25kHz, 0.5kHz kunye ne-1kHz.
2. Unikezelo lomlinganiselo wohlobo lokutshayela
Tshayela uluhlu lomlinganiselo wokuphindaphinda: (0.5kHz) - (1MHz), amanqaku angama-2000 wokuskena;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Ezinye iiparamitha zobugcisa:
1. Uluhlu lomlinganiselo we-Amplitude: (-120dB) ukuya (+20 dB);
2. Ukuchaneka komlinganiselo we-Amplitude: 1dB;
3. Tshayela ukuchaneka kwamaza: 0.005%;
4. Ukuphazamiseka kwegalelo lomqondiso: 1MΩ;
5. Ukuphazamiseka kwemveliso yomqondiso: 50Ω;
6. Ubungakanani bemveliso yesignali: ± 20V;
7. Inqanaba lokuphinda uvavanyo lwenqanaba: 99.9%;
8. Imilinganiselo yezixhobo zokulinganisa (LxWxH): 340X240X210 (mm);
9. Ubungakanani bebhokisi ye-aluminium yesixhobo (LxWxH): 370X280X260 (mm);Ibhokisi yocingo ye-aluminium ingxubevange ibhokisi (LxWxH) 420X300X300 (mm);
10. Ubunzima bubonke: 10kg;
11. Ubushushu bokusebenza: -10℃~+40℃;
12. Ubushushu bokugcina: -20℃~+70℃;
13. Ukufuma okuhambelanayo: <90%, Ukungaguquguquki;