GDB-D Transformer Turn Ratio Tester
Umvavanyi we-GDB-D Transformer turn ratio yenzelwe izigaba ezithathu zesiguquli kwinkqubo yamandla kwaye ngakumbi kuhlobo lwe-Z olujikozayo lwesiguquli kunye nezinye iziguquli ezinomthwalo omkhulu ngokwangoku.
-
I-GDB-H i-Handheld Automatic Transformer iJika iRetio Tester
Inokulinganisa ngokuchanekileyo umlinganiselo wokujika, iqela kunye ne-angle yesigaba, ezifanelekileyo kuzo zonke iintlobo zeenguqu ezifana ne-Z uhlobo lwe-transformers, i-rectifier transformer, i-firnace transformers yombane, i-phase-shifting transformers, i-traction transformers, i-scott kunye ne-invert-scott transformers.
-
I-GDB-IV yeSigaba seSithathu isiGuquli siJika iRetio Tester
Imodyuli yamandla yangaphakathi kumvavanyi ivelisa amandla esigaba sesithathu okanye amandla amabini, aphuma kwicala eliphezulu le-voltage ye-transformer.Emva koko i-voltage ephezulu kunye ne-voltage ephantsi isampuliwe ngaxeshanye.Ekugqibeleni, iqela, umlinganiselo,impazamo,kwaye umahluko wesigaba ubalwa.
-
I-GD6900 yeCapacitance kunye ne-Disipation Factor Tester
I-GD6900 ilinganisa i-capacitance kunye ne-dielectric loss factor (tgδ) yezixhobo zombane zombane ophezulu.Isakhiwo esidibeneyo, ibhulorho yokuvavanya ilahleko ye-dielectric eyakhelwe-ngaphakathi, unikezelo lwamandla oluguquguqukayo oluguquguqukayo, i-boosting transformer kunye ne-SF6 capacitor eqhelekileyo.
-
I-GDZRC Series DC Winding Resistance Tester (GDZRC-10A)
GDJRC-10A
GDFRC series DC umvavanyi ukumelana namajiko-jikoyenzelwe ukulinganisa uxhathiso lwe-DC lwe-inductiveizixhobo, ezifana neziguquli kunye nee-inductors zamandla.
Ineempawu zokulinganisa ngokukhawuleza, ubungakanani obuncincikunye nokuchaneka okuphezulu komlinganiselo, esisixhobo esifanelekileyoyokulinganisa ukujikajika kwesiguquli kunye noxhathiso lweDC lweizixhobo ezinkulu zokungenisa amandla. -
I-GD6800 yeCapacitance kunye ne-Disipation Factor Tester
GD6800 ingokuzenzekela ngokupheleleyo 10Uvavanyo lwe-kV insulation power factor/dissipation factor (tan∂).ereyilelwe uhlolo lwemeko yokugquma umbane kwizixhobo zombane eziphezulu ezifana neziguquli, amahlahla, iziphuli-moya, iintambo, izibambisi mbane kunye noomatshini abajikelezayo.
-
GDZRS-20A IsiGaba esiThathu se-DC Winding Resistance Tester
Lo mvavanyi we-DC wokuxhathisa okhawulezayo (emva koku ubizwa ngokuba ngumvavanyi wokuxhathisa ukugoba kwe-DC) yimveliso yamva nje yokulinganisa uxhathiso lwe-DC lweziguquli.Ilungiselelwe ukulinganisa ukuxhathisa kwe-DC kwii-windings ezithathu ze-transformers ezinkulu.Ukuchasana kwe-DC ye-windings yesigaba sesithathu se-transformer kunokuvavanywa ngaxeshanye.Kwi-voltage elawula i-voltage elawula i-voltage, akufuneki ukuba ukhuphe umtshintshi wetephu ngokuthe ngqo, kwaye ixesha lokulinganisa lisinye kwisithathu somlinganiselo wenqanaba elinye, elinokunciphisa kakhulu ixesha lokusebenza kunye nokuqina kwabasebenzi.Imitha yokuchasa ngokuthe ngqo ithatha isiboniso esikhulu sekristale yolwelo lwescreen, yonke imbonakalo yegraphical yaseTshayina, icacile kwaye iyaqondakala, kwaye ukusebenza kulula kakhulu.Kwaye ixhotyiswe ngomshicileli wepaneli kunye nememori enkulu engaguqukiyo, unokugcina ngokulula kwaye uprinte iziphumo zomlinganiselo.Idatha yovavanyo izinzile, iyakhawuleza kwaye iyaphinda, kwaye lolona khetho lungcono lokulinganisa ukuxhathisa kwe-DC kwi-transformers kwisiza.
-
I-GD6100 ye-Insulation Oli ye-Tan Delta Tester (i-Oil Dissipation Factor Tester)
I-GD6100 sisixhobo esichanekileyo sokuvavanya i-dielectric loss angle kunye ne-volume resistivity of insulating oil or other insulating liquids.
-
GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
Kukho inani elikhulu lezixhobo zombane kwinkqubo yamandla, inkqubo kaloliwe kunye nemigodi yezityalo zepetrochemical ezinkulu kunye namashishini, ukugquma kwabo kwangaphakathi kuninzi kufakwe i-oyile.Amandla e-dielectric ye-oyile ekhuselayo luvavanyo lwesiqhelo olunyanzelekileyo.Ukuze kuhlangatyezwane neemfuno zemarike, inkampani yethu yaphuhlisa kwaye yavelisa uluhlu lwabavavanyi bamandla e-dielectric yeoli ye-dielectric ngokomgangatho wesizwe we-GB/T507-2002 (IEC156), umgangatho we-DL429.9-91 kunye nomgangatho wamva nje weshishini lamandla. DL/T846.7-2004.Esi sixhobo sithatha i-microcomputer ye-single-chip njengeyona nto ingundoqo, iqonda yonke i-automation yovavanyo, inomlinganiselo ophezulu wokuchaneka komlinganiselo, iphucula kakhulu ukusebenza kakuhle, kwaye inciphisa kakhulu amandla omsebenzi wabasebenzi.Ngexesha elifanayo, isixhobo sinembonakalo edibeneyo kwaye ikulungele ukuthwala.
-
I-GDOT-80A yoMvavanyi we-oyile yokugquma
Nceda ufunde incwadi yokusebenza ngononophelo phambi kokuba usebenze.
Nceda ujonge ukuba umvavanyi uqhagamshelwe kakuhle emhlabeni phambi kovavanyo.
Akuvumelekanga ukuhambisa okanye ukuphakamisa ikhava yokuvavanya kwinkqubo yokuvavanya ukuphepha ukulimala ngombane ophezulu.Umbane kufuneka ucinywe phambi kokuba kubuyiselwe ioyile yesampulu. -
GDKC-5000 Transformer On Load Tap Changer Tester
I-GDKC-5000 Transformer On Load Tap Changer Tester inokulinganisa ngokuchanekileyo ixesha elidlulayo, i-waveform yesikhashana, ukuchasana okwexeshana, ulungelelwaniso lwezigaba ezithathu kunye nezinye iiparameters zokutshintsha itephu yomthwalo.Sisixhobo esifanelekileyo sovavanyo lokutshintsha impompo yomthwalo.Ihlangabezana neemfuno zokujonga ulandelelwano lwesenzo sokutshintsha impompo yomthwalo kunye nokulinganisa ixesha lokutshintsha.
-
Ibhentshi yoVavanyo lwe-GDBT-1000kVA
Inkqubo yovavanyo ye-GDBT Transformer inokuqhuba zonke iimvavanyo zesiqhelo ze-transformer, kubandakanywa novavanyo lwe-No-load kunye nomthwalo, uvavanyo lwe-voltage ye-Induced, i-Power frequency ukumelana novavanyo lwe-voltage, uvavanyo lokukhupha inxalenye, uvavanyo lokumelana ne-DC, uvavanyo lomlinganiselo wokujika, uvavanyo lokunyuka kobushushu njl.