I-GD6800 yeCapacitance kunye ne-Disipation Factor Tester

I-GD6800 yeCapacitance kunye ne-Disipation Factor Tester

Ingcaciso emfutshane:

GD6800 ingokuzenzekela ngokupheleleyo 10Uvavanyo lwe-kV insulation power factor/dissipation factor (tan∂).ereyilelwe uhlolo lwemeko yokugquma umbane kwizixhobo zombane eziphezulu ezifana neziguquli, amahlahla, iziphuli-moya, iintambo, izibambisi mbane kunye noomatshini abajikelezayo.

 

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

GD6800
Iimbonakalo

Isikrini esikhulu sokuchukumisa isibonisi sesiNgesi
Ukugcinwa okukhulu kwangaphakathi kunye nenkxaso yokugcina i-U-disk
Ukhuseleko oluninzi, lukhuselekile kwaye luthembekile
Iindlela ezininzi zovavanyo: UST, GST, GSTg
Uyilo olukhaphukhaphu, oluhexayo lwesiqwenga esinye
Amandla ombane aphezulu 10kV/200mA (12kV inokwenziwa ngokwezifiso)
Umlinganiselo ozenzekelayo we-LCR
Ukunyanzeliswa kokuphazamiseka
Ukuchaneka okuphezulu

Iinkcukacha
Imeko yokusebenza -15℃~40℃ RH<80%
Umgaqo wokuchasana nokuphazamiseka Uguqulo rhoqo
Ukunikezwa amandla I-AC 220V ± 10% Ijenereyitha ingasetyenziswa.
Ukukhutshwa kwamandla aphezulu 0.5KV~10KV Rhoqo nge-0.1kV
Ukuchaneka 2%
Max.yangoku 200mA
Umthamo 2000VA
Amandla okuzivuselela AC 0V~50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Ukuzenzekela kabini rhoqo
Isigqibo tgδ: 0.001% Cx: 0.001pF
Ukuchaneka ∆tgδ: ±(ukufunda*1.0%+0.040%)
∆C x: ±(ukufunda*1.0%+1.00PF)
Uluhlu lomlinganiselo tgδ Ngaphandle komda
C x 15pF<Cx<300nF
10KV Cx <60 nF
5KV Cx <150 nF
1KV Cx <300 nF
Uvavanyo lwe-CVT Cx <300 nF
Uluhlu lomlinganiselo we-LCR L>20H(2kV) R>10KΩ(2kV)
Ukuchaneka komlinganiselo we-LCR 0.1% Isisombululo se-engile 0.01
Uluhlu lomlinganiselo weCVT 10~10000
Ukuchaneka komlinganiselo we-CVT 0.1%
Isisombululo somlinganiselo weCVT 0.01
Ubungakanani Iyunithi ephambili:470 (L) ×370 (W) ×380(H)
Ibhokisi yezincedisi:430 (L) ×350 (W) × 130(H)
Umthamo wenkumbulo Amaqela angama-200, ukugcinwa kwe-USB flash disk kuyaxhaswa.
Ubunzima Iyunithi ephambili: 22.75Kg
Ibhokisi yesincedisi: 5.25Kg
Izincedisi ezisemgangathweni
Ityala eliphetheyo 1 pc
I-HV ikhokelela kwi-8m 1 pc
Uvavanyo lwe-LV lukhokelela kwi-8m 1 pc
Intambo yamandla 1.8m 1 pc
I-CVT iQhagamshela isikhokelo 5m 1 pc
Umkhondo ophantsi 2m 1 pc
Iphepha lokuprinta Imiqulu emi-2
10A fuse iipcs ezi-2
Isikhokelo somsebenzisi 1 pc
Ingxelo yovavanyo lwasefektri 1 pc
Izincedisi ozikhethelayo 
Oyile Test cell 1 pc
Isilawuli sokufudumeza 1 pc

Ngeseli yovavanyo lweoyile kunye nesilawuli sokufudumeza, umsebenzisi unokuvavanya i-tan delta yolwelo lwe-dielectric olufana neoyile ye-transformer.

Heating controller

Isilawuli sokufudumeza

Oil vessel

Isitya se-oyile