GMDL-02A HV Circuit Breaker Analog isixhobo

GMDL-02A HV Circuit Breaker Analog isixhobo

Ingcaciso emfutshane:

Isixhobo sokulinganisa i-GMDL-02A ye-high-voltage circuit breaker simulation senziwa kusetyenziswa imigaqo yoluhlu lwesango elikhulu elicwangcisiweyo, izixhobo zombane zombane kunye nokukhusela, njl.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iinkcukacha zajikelele

Isixhobo sokulinganisa i-GMDL-02A ye-high-voltage circuit breaker simulation senziwa kusetyenziswa imigaqo yoluhlu lwesango elikhulu elicwangcisiweyo, izixhobo zombane zombane kunye nokukhusela, njl.

Ikhoyili evulekileyo yenzelwe ngokwe-loop ezimeleyo, enokuthi ifanise isigaba sesithathu kunye nokusebenza kwesigaba sokwahlula kwinqanaba le-voltage ye-6-110KV.Indlela yokuziphatha ye-coil evulekileyo ye-coil breaker ilungele ukhetho lweenkqubo zamandla, amashishini amashishini kunye nemigodi, amaziko ophando lwezenzululwazi, iikholeji zobungcali kunye nabavelisi bokukhusela.

Isetyenziselwa indawo yabaphuli beesekethe zangempela kuvavanyo lokuhanjiswa kwenkqubo yonke yokukhusela i-relay kunye nezixhobo ezizenzekelayo ezinokutshintsha.

Isenzo sichanekile, sithembekile, kwaye inani lezenzo alikhawulelwanga, elinokuphucula kakhulu ukuchaneka kunye nokuphelela kovavanyo, ukunciphisa inani lezenzo ze-breaker circuit real, kunye nokwandisa ubomi benkonzo.Sisixhobo esibalulekileyo esixhasayo kumsebenzi wovavanyo lokhuselo lwe-relay.

Iimbonakalo
Amandla ombane asebenzayo: I-AC220V±10% 50HZ esebenzayo yangoku ingaphantsi kwe-0.5A
Vula kwaye uvale amandla ombane osebenzayo: I-DC200V okanye i-DC110V.
ixesha lokuvula kunye nokuvala Ukukhetha ixesha lokuvula: Ukuvala ixesha lokukhetha:
20ms, 30ms, 40ms, 50ms, 60ms, 70ms, 90ms, 110ms, impazamo ayidluli ±5ms 40 ms, 60 ms, 80 ms, 100 ms, 200 ms, 300 ms, 400 ms, 500 ms, impazamo ayidluli ±5ms, (xa 500ms, impazamo ayidluli ±20ms).

ukuvula nokuvala okwangoku vula ukhetho lokumelana: ∞Ω, 100Ω, 200Ω, 400Ω
Ukuvala ukhetho lokuchasa: ∞Ω, 100Ω, 200Ω, 400Ω
Ukuvula kunye nokuvala okwangoku kunqunyulwa ngokuzenzekelayo ngexesha lokuvula nokuvalwa.
Ukuvula nokuvala ngesandla Xa isixhobo sokulinganisa i-high-voltage circuit breaker simulation siqhutywa nge "manual close" kunye namaqhosha "avulekileyo" kwiphaneli, i-high-voltage circuit breaker simulation device ivuliwe, kwaye akukho mpompozo yangoku kwikhoyili yokuvala.
Ukungaphumeleli kwebreaker Xa iqhosha lokungaphumeleli kwe-circuit breaker licinezelekile, i-circuit breaker ayisebenzi, i-currents yokuvula kunye nokuvala ilibazisekile emva kwe-1 kwaye ikhutshwe, kwaye imeko yangoku ibuyiselwe emva kwenye i-20s.
Zobela ngaphandle Zobela ngaphandle:
I-DC220V/0.5A, AC220V/5A.
Uqhagamshelwano lwemveliso yesaphuli sesekethe: Izibini ze-12 ze-circuit breaker position output contacts, ezizimeleyo komnye nomnye.Ukwahlulwe ngamaqela amabini, ahambelana ne-coil evulekileyo ye-circuit breaker.
Ukuvala isandla, ukutsiba ngesandla: Ukuvala ngesandla kunye namaqhosha okutsiba ngesandla ngalinye linepere ye-synchronous output edla ngokuvula abafowunelwa.Xa isandla sivala kwaye amaqhosha okutsiba esandla ecinezelwe, umfowunelwa uyadityaniswa.Phakathi kwabo, uqhagamshelwano oluvaliweyo ngesandla luzigcina ngokwalo emva kwesenzo, kwaye usethe kwakhona ngeqhosha lokuxhuma ngesandla.Xa iqhosha lokutsiba ngesandla likhutshwe, i-hand-jump contact iya kubuya ngokulibaziseka kwe-60ms.

  • Ngaphambili:
  • Okulandelayo:

  • Thumela umyalezo wakho kuthi:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi

    Thumela umyalezo wakho kuthi:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi