I-GDYM-3M i-Multi-functional Energy Meter Calibrator
Iimpawu zamva nje
1. I-32-bit yesantya esiphezulu seprosesa yesignali yedijithali
Ukusebenzisa i-32-bit yesantya esiphezulu se-120MHz DPS ye-TI, kunye nokusebenza okuphezulu kwe-16-bit AD kunye namajelo ama-6.Iiyunithi zophindaphindo lwedijithali ezinemisebenzi emininzi kunye noluhlu olubanzi lomlinganiselo lwaphuhliswa ngempumelelo ngendlela yokubala amanqaku adadayo. Ngoko ke, ukubala ukuchaneka kunokuqinisekiswa.
2. Umsebenzi wokulinganisa iWring
Iindlela ezahlukeneyo ze-wiring zingenziwa kwaye zifumane iziphumo ezihambelanayo kwiofisi yi-calibrator ngaphandle kokudibanisa i-voltage okanye izibonakaliso zangoku.Lo msebenzi uya kusetyenziswa njengezixhobo zoqeqesho kunye nezixhobo zoqeqesho lwezakhono zokuhlola umgca.Ukwazi ukuphucula kakhulu izakhono zokuhlola abasebenzi abasebenza kwindawo.
3. Impazamo yokuzijonga i-5A clamp
I-5A kunye ne-0.5A isignali yangoku iya kuveliswa kwaye iphume kwi-5A kunye ne-100A i-clamp, ukwenzela ukulinganisa iimpazamo ze-clamp.Isombulule ingxaki yokwahluka kwempazamo ye-5A kunye ne-100A ibamba emva kokusetyenziswa kwexesha elide, ivumela umqhubi ukuba aqonde imeko yokuvala i-clamp kwaye ikhumbuze abasebenzi ukuba bacoce umhlathi we-clamp kwangethuba.
4. Uluhlu olubanzi lomlinganiselo lwangoku
Ukuya kuthi ga kwi-500 amaxesha angoku uluhlu lokulinganisa ukuqinisekisa isalathisi somlinganiselo.Ukuya kuthi ga kwi-10000 amaxesha okuboniswa koluhlu lwangoku.Ubuncinane bokuqalisa ngoku yi-1mA.Iingcingo ziyakwazi ukuchongwa nakwimeko yokungabikho komthwalo.
5. Umsebenzi okhulayo wamandla ombane
Ukulinganisa imitha yamandla ngaphandle kwemveliso ye-elektroniki ye-pulse yamandla.Okanye inokuthathwa njengesalathiso sovavanyo lokonga amandla.
6. Ukuhlolwa okungenazingcingo
Uhlolo olubanzi lweempazamo zenkqubo yokulinganisa kwindawo, ukujonga impazamo edibeneyo yombane ophezulu kunye nombane ophantsi.
Ezinye iimpawu
1. Ukusebenzisa i-4.7 intshi 16: 9 TFT isikrini se-LCD, ukusebenza okucacileyo kunye nokuhle, ukulungiswa okuphezulu, ulwazi oluninzi kunye nomxholo ocebileyo.Umsebenzi ngamnye we-calibrator uboniswa kwiscreen esinye, akukho mfuneko yokuflip isikrini ukuze ubone zonke iiparameters zomsebenzi ngamnye.Yenza abasebenzisi bacace ngokupheleleyo malunga necalibrator ngexesha lokusebenzisa..
2. Iimpazamo, i-voltage, yangoku, amandla asebenzayo kunye ne-reactive, isigaba, i-frequency, kunye ne-power factor inokulinganiswa ngaxeshanye, kunye ne-vector figure kunye neziphumo zocingo ziya kuboniswa.
3. Ngaphandle kweyiphi na i-resistor ehlengahlengiswayo kwi-calibrator, zonke iimpazamo ziya kuguqulwa ngesofthiwe.
4. Umlinganiselo wombane ophantsi we-CT unokulinganiswa ngokuthe ngqo kunye ne-5A, 100A, 500A, 1000A i-clamp.Zonke iziphoso, ezifana nokuqhawula, uxhulumaniso olubi lwesiphaluka sesibini se-CT, isiphaluka esifutshane sokujika ngaphakathi kwe-CT, kunye ne-CT nameplate ratio iyahambelana ne-CT real turns ratio okanye akunjalo, njl.
5. I-voltage kunye ne-harmonic yangoku ukusuka kwi-2 ukuya ku-21 amaxesha e-A, B, C isigaba sinokulinganiswa ngexesha langempela ukwazi umgangatho wombane wegridi yamandla.
6. Ifom ye-wave ye-A, B, C ye-voltage yesigaba sesithathu okanye yangoku inokulinganiswa kwaye iboniswe.
7. Uluhlu olubanzi lombane ukusuka kwi-45V ukuya kwi-480V.
8. Zonke iiparamitha ze-in-site input kunye nedatha zinokuchazwa ngumsebenzisi.Idatha ye-1000 yomsebenzisi inokukhutshelwa.
●I-calibrator iya kwenza i-alamu ngesandi kunye nokukhanya xa unikezela nge-380V kumgca wokuvavanya umbane.
●Xa ukulinganisa umthwalo wangoku umgca ungalunganga uxhunywe kumgca ongathathi hlangothi wemitha, ukhuseleko lokuqala oluzenzekelayo aluyi kuphuma okwangoku.Xa udibanisa impazamo kwakhona, i-fuse yesibini yokukhusela iya kutshiswa, esebenza ngokukhuselekileyo.I-calibrator iya kuphola emva kokutshintsha i-fuse.
●I-fuse iya kutsha xaUmgca wempembelelo ubethe i-220V, i-calibrator iya kuphola emva kokubuyisela i-fuse.
| Uluhlu lwamandla ombane | 30V-480V | 5A | Amandla amandla asebenzayo, amandla | ±0.5% | |
| Imposiso yombane | ±0.2% | Amandla asebenzayo asebenzayo, amandla | ±0.5% | ||
| Ibamba (amaxesha ama-1 ngaphezulu komthwalo) | 5A,100A,500A,1000A | Okwangoku | ±0.5% | ||
| Uluhlu lwezakhelo zokuNgenisa | 45-55Hz | Ukuzijonga ngoku | 5A 0.5A | ||
| Impazamo yoMlinganiselo wamaxesha amaninzi | ±0.01Hz | Impazamo yokuzijonga | ±0.1% | ||
| Uluhlu loMlinganiso weSigaba | -180 ° ~ +180 ° | I-Clamp enkulu yangoku | Amandla amandla asebenzayo, amandla | ±0.5% | |
| Imposiso yesiGaba esiPhezulu | ±0.1° | Amandla asebenzayo asebenzayo, amandla | ±0.5% | ||
| Umlinganiselo weHarmonic | ±0.1% | Okwangoku | ±0.5% | ||
| Uluhlu loMlinganiselo weHarmonic | 2-51 amaxesha | Abanye | Umlinganiselo womlinganiselo | ±0.5% | |
| Itheminali yangoku | Amandla amandla asebenzayo | ±0.1% | Impembelelo yombane | < ±0.01% | |
| Amandla asebenzayo asebenzayo | ±0.5% | Impembelelo rhoqo | < ±0.01% | ||
| I-Frequency ephantsi ye-Pulse Constant | 5A | 3600P/kWh | Impembelelo yobushushu | < ±0.005%/ºC | |
| Abanye | 3600*(5/Ie) | Impazamo yokutshintsha iiyure ezingama-24 | < ±0.04% | ||
| P/kWh | |||||
| Impembelelo yeHarmonic | < ±0.01% | ||||
| Qaphela: Oko kukuthi, ilinganiswe ngoku | Ixesha lokulinda emva kokuqalisa | ||||
| Ukunikezwa Amandla | I-AC 45V - 480V | Ubushushu bendalo | -25ºC- +45ºC | ||
| Ukutya umbane | <10W | Ubuntu bezizalwane | 40%-95% | ||
| Ubungakanani | 214mm * 158mm * 71mm | Ixesha eliqhubekayo lokusebenza kwebhetri | >8 iiyure | ||
| Ubunzima | < 1.2 kg | Amandla ombane wokutshaja ibhetri | I-DC 12V | ||
| I-GDYM-3M Calibrator | Iseti e-1 |
| 100A imitha yokubamba | Iziqwenga ezi-3 |
| Iringi yokulungisa | Iqhekeza eli-1 |
| Isoftware yoLawulo (CD-ROM) | Iqhekeza eli-1 |
| Isikhokelo sovavanyo | Iqhekeza eli-1 |
| Umgca we-Electronic meter pulse | Iqhekeza eli-1 |
| Intambo yamandla | Iqhekeza eli-1 |
| 232 umgca wonxibelelwano | Iqhekeza eli-1 |
| Intloko yombane | Iqhekeza eli-1 |
| Iadaptha | Iqhekeza eli-1 |
| Ityala lesixhobo | Iqhekeza eli-1 |
| Imanyuwali | Ikopi enye |