I-GDYB-S3 Inkqubo yoVavanyo lwemitha yeSigaba esiThathu (izithuba ezi-3)
Ukuchaneka kwenkqubo: 0.1%;
Ipharamitha yomthombo wesigaba esithathu:
a.Umbane ophumayo:
3*57.7VY 3*100V ∆ ;
3*220V Y 3*380V ∆;
Uluhlu oluhlengahlengiswayo 0~120% ngokuqhubekayo oluhlengahlengiswayo
Uhlengahlengiso lwezonelelo: ngcono kune-0.01%
b.Imveliso yangoku: 25mA, 0.1A, 1A, 5A, 25A, 100A;
Uluhlu oluhlengahlengiswayo 0~120% ngokuqhubekayo oluhlengahlengiswayo
Uhlengahlengiso lwezonelelo: ngcono kune-0.01%
Imveliso encinci yangoku: 1mA (ukuchaneka: <5%)
c.Imveliso yamandla: (i-voltage circuit) 3 * 50VA
(isekethe yangoku) 3 * 150VA
d.Imveliso yombane, yangoku, uzinzo lwamandla: ≤0.02%/120S
e.Iqondo lokugqwesa umbane ophumayo kunye nemo yamaza yangoku: ≤0.5%
f.I-Symmetry yee-engile zesigaba esithathu: phakathi kwe-120 ° ± 0.3 °
g.Uluhlu lokuphindaphinda: 45Hz~ 65Hz, inyathelo: 0.01Hz
h.Uluhlu lwe-engile yesigaba: -180 ° ~ 180 °, inyathelo: 0.01 °
i.Ukubonisa ukuchaneka kweemitha: I-Voltmeter, i-ammeter: ±0.01%
imitha yenqanaba: ± 0.01 °
Imitha yokuphindaphinda: ±0.01Hz
Ubuncinci beMiphumo yangoku: 1mA;ukuchaneka: ≤5%;
Umthamo womthwalo wemveliso (iimitha ezingama-20)
Imveliso yombane: 800VA;
Imveliso yangoku: 2500VA;
Umbane kunye nohlengahlengiso lwangoku
Uluhlu olunokulungiswa: (0% ~ 120%) x uluhlu lokulinganisa;
Ukulungiswa kokulungiswa: 10%, 1%, 0.1%, 0.01%;
Uhlengahlengiso lwenqanaba:
Uluhlu olunokulungiswa: 0 ° ~ 360 °;
Ubuncinci obunokulungiswa: 10 °, 1 °, 0.1 °, 0.01 °;
Uhlengahlengiso lwamaxesha:
Uluhlu olunokulungiswa: 45Hz ~ 65Hz;
Ukulungiswa kokulunga: 1Hz, 0.1Hz, 0.01Hz;
Uzinzo lwamandla emveliso: ≤0.05%/120S;
Umbane ophumayo kunye nokugqwetheka kwangoku:
Umbane: ≤0.5%;
Okwangoku: ≤0.5%;
Iisetingi zeHarmonic:
Inombolo yeHarmonic: 2 ~ 21 amaxesha;
Umxholo we-Harmonic: ngoku i-2 ~ 21 amaxesha ≤40% (ngokumalunga ne-wave basic);
i-voltage 2 ~ 21 amaxesha ≤40% (ngokunxulumene namaza asisiseko);
Isigaba seHarmonic: 0 ° ~ 359.99 °;
Isixhobo sokubeka iliso:
Ukuchaneka komgangatho wokubonisa imitha: I-Voltage: 0.01%;
Okwangoku: 0.01%;
Amandla: 0.01%;
Isigaba: 0.01;
Ukuphindaphinda: 0.01;
I-insulated 1:1 iparamitha yangoku yesiguquli:
Ukuchaneka: 0.01%;
Amandla okuvelisa: 60VA;
Uluhlu lwangoku lokulinganisa: 1mA~120A (1:1);
Isalathiso sentsebenzo engundoqo
a) Ukuchaneka: 0.01% (COS∮=0.5C…1…0.5L);
b) Ireyithingi rhoqo: 50Hz / 60Hz ± 5%;
c) Ngoku ephambili: 3 × 0.001-120A;
d) Isibini sangoku: 3 × 0.001-120A;
e) Umthwalo wemveliso (isigaba ngasinye):
0.5W (uluhlu lwemveliso: 0.001-1A);
I-0.7V ihlulwe ngexabiso langoku (uluhlu lwemveliso: 1-120A);
f) Umthamo wombane ophumayo: Ubuninzi.0.5V (imveliso yangoku Max. 120A);
Ubungakanani benguqu yangoku: 265 x 200 x 240 mm (L x W x H);
Ubunzima: 12kg;
Ubungakanani:
Umthombo wokulawula: 610 x 800 x 1920mm (L x W x H);
I-rack yemitha: 2350 x 750 x 1850mm (L x W x H);