I-GDYM-3F ephathekayo ye-Energy Meter Calibrator
●Ngokungqamanisa ukubala zonke iiparamitha kunye nokuboniswa kwi-interface kubandakanya i-wave epheleleyo, i-wave wave kunye ne-harmonic wave njengexesha elifanayo ubonisa u-U, I, P, Q, VA, i-angle yesigaba malunga namaza apheleleyo kunye namaza asisiseko kunye ne-harmonic synthesis ye-I, U, P, Q, VA kunye nepesenti yayo, umxholo we-U, ulandelelwano oluhle, ulandelelwano olubi, ulandelelwano lwe-zero kunye ne-harmonics ye-PH +, PH-, PH +/Pf%, PH-/Pf%, i-PF epheleleyo, i-wave wave PF, i-harmonic wave PF.
●Indlela yokuhlola ibandakanya iintlobo ezisi-7 zeendlela zamaza apheleleyo asebenzayo, amaza apheleleyo asebenzayo, amaza apheleleyo abonakalayo, amaza asisiseko asebenzayo, amandla asisiseko asebenzayo, amaza asisiseko abonakalayo kunye namaza e-harmonic, anokukhangela ukuchaneka kwamandla asebenzayo emitha yamaza apheleleyo, isiseko. imitha, imitha yamaza e-harmonic kunye nokuchaneka kwamandla asebenzayo amaza amaza apheleleyo kunye nemitha yamaza e-harmonic, inokukhangela ukuchaneka okucacileyo kwemitha yamandla ombane.
●Ukuzikhethela enye okanye ngaphezulu i-harmonic ukubala ikhompawundi ye-harmonic ye-U, I, P, Q, VA kunye nepesenti yayo kunye ne-harmonic wave esebenzayo yamandla ombane.
●Ngaxeshanye icandelo lokuhlalutya elinye kunye nexabiso lokulinganisa ixesha ngalinye i-U, I, P, Q, VA yesigaba sesithathu samaza e-harmonic kwaye ibonise amaxesha ayo angama-51 + PH/-PH kunye nepesenti yamaza asisiseko ukumisela impembelelo ye-harmonic elungileyo nengalunganga ukulinganisa iimitha.
●Amandla asebenzayo apheleleyo sisimbuku sealgebraic samandla asebenzayo amaza asisiseko kunye namaza eharmonic yeharmonic nganye.Ukuze ugweme utshintsho lwesigaba se-90 kwixesha elidlulileyo kwaye kwimeko ye-harmonic wave reactive impazamo yovavanyo lwamandla.Sinokulinganisa i-brand ngemitha yamandla ombane enokuthi ibonwe kwaye sikhethe inani le-harmonic wave nganye.
●Kwangaxeshanye uvavanye i-pulse echongiweyo emibini, kunye nemowudi eqhubekayo, yokusebenza kunye nenani lee-pulse ezichongiweyo ngexesha elinye linokwahluka ngokupheleleyo.
●Ukugqithiswa kwamaxesha e-2.4, onke amanqaku okulinganisa anokuqinisekisa ukuba ukuchaneka kwe-0.05% kwaye kwakhona kuqinisekiswe isalathisi somlinganiselo we-CT yesibini ye-secondary rated current xa i-1A.
●Amaxesha angama-500 ngoku uluhlu lwangoku luqinisekisa isalathisi sokulinganisa, amaxesha angama-1000 abonisa uluhlu lwangoku, ubuncinane be-1mA yokuqala yangoku.Ngexesha elifanayo lokunikezelwa kwamandla ombane ophezulu, i-high-voltage device ilinganiswa, kwaye i-wiring inokuchongwa ngokungabikho komthwalo.
●Umsebenzi wokuqokelela amandla ombane unokulinganisa imitha yamandla ombane ongenayo i-pulse output.
●Bonisa i-vector diagram, inokuchonga i-3-wire of 48 i-wiring engalunganga kunye ne-four-wire ye-96 i-wiring engalunganga kunye ne-CT yesibini yokuwela iintambo.
●I-Adopt 7 intshi 16: i-9 ibakala loshishino kunye nobubanzi besikrini sombala we-TFT, iparameter nganye yomsebenzi wesixhobo ibonakaliswe ngokuthe ngqo kwaye icacile kwisikrini ngaxeshanye ngaphandle kokujika kwesikrini , vumela abasebenzisi ukuba basebenzise ngokujonga.
●Isixhobo sinokulinganisa iindidi zeengcingo zescene kwaye ufumane iziphumo ezihambelanayo zocingo kunye ne-coefficient yokulungisa eofisini ngaphandle kokufikelela kumbane okanye umqondiso wangoku.Lo msebenzi unokusetyenziswa njengesixhobo sokuhlola umgca woqeqesho ukuze kuphuculwe izakhono zokujonga umgca wabasebenzi bangaphandle.
●Isixhobo sangaphakathi sinokuvelisa uphawu lwangoku lwangoku lwe-0.05-5A kwaye lufakwe kwi-5A i-clamp ukujonga impazamo ye-clamp meter.Ukucinga kwi-akhawunti ye-5A clamp inengxaki yokutshintsha impazamo emva kokusetyenziswa ixesha elide.Yenza ukuba uhlale usazi imeko yokuvala malunga nemitha yocingo nangaliphi na ixesha, khumbuza abasebenzi abafanelekileyo kwangethuba ukuba bacoce umhlathi obambezelayo.Xa utshintsha i-5A clamp, impazamo inokulungiswa kwi-0.2.
●Ngenisa ngokuzenzekela inombolo yemitha yamandla (umsebenzi owuthandayo)
Inkxaso yebarcode scanner kunye nekhowudi yemitha yamandla yokufaka ngokuzenzekelayo.
●Sebenzisa i-485 okanye i-infrared photoelectric head ukuze ufunde i-multi-function meter imitha ithiphu, incopho, iflethi, intlambo, isiseko esisebenzayo nesisebenzayo, ukufunda rhoqo kunye nexesha.Ukuxhasa umgangatho kazwelonke we-DL645 imimiselo, i-DL645-1997 kunye ne-DL645-2007.(umsebenzi ozikhethelayo)
●Idiski ye-elektroniki eyakhelweyo ye-2G.
●Inokuxhotyiswa ngomshicileli wentsimi we-intshi ezi-3, amandla ebhetri, kwaye iguqule ngokuthe ngqo umfanekiso weskrini sombala ube mnyama namhlophe xa ushicilelwa.(ukhetho)
●Ukusebenzisa i-clamp meter (5A, 100A, 500A, 1000A) ngokuthe ngqo ukulinganisa umlinganiselo kunye nephutha lomlinganiselo we-low voltage current transformer.(100A, 500A, 1000A into yokubamba iyakhethwa)
●Bonisa amandla ombane kunye nemo yamaza yangoku yesigaba esithathu A, B, C.
●Uluhlu lwegalelo lamandla omsebenzi yi-55V-600V.Isiseko sombane esiqhelekileyo samanqanaba amathathu ombane yi-600V.Ukutshintsha kwemizi-mveliso ukutshintshela uqhagamshelo lombane wesixeko kunye nesigaba sesithathu sombane njengamandla omsebenzi.
●Zonke iiparameters ezifuna ukufakwa kwisayithi kunye nedatha ekhutshelweyo inokuchazwa ngokukhululekile ngumsebenzisi.Iyakwazi ukukhuphela idatha yabasebenzisi be-5000.
●Isikrini sangoku sinokugcinwa kwidiski ye-U.
●Ngomsebenzi wokulinganisa ubushushu kunye nokufuma (kufuneka ufakele ubushushu kunye nenzwa yokufuma).
●Nge-interface ye-USB kwaye idibanisa kwi-USB flash drive ukwenza indawo enkulu yokukhuphela idatha.
●Chukumisa isikrini kwaye ucinezele ukusebenza kwesitshixo, ikhibhodi usebenzisa ilungiselelo lekholamu yebhodibhodi yekhompyuter.Ikhibhodi yePC enojongano lwe-USB nayo iyafumaneka.
●Ixesha kunye nomatshini wePC ngojongano lwe-USB.
●Ikhompyuter yethebhulethi inokulawula ngokuthe ngqo isixhobo esine-interface yokusebenza efanayo njengesixhobo.
●Isokhethi yokulinganisa i-voltage kunye nokutshintsha amandla okutshintsha kwibakala lemizi-mveliso ingasetyenziswa phantsi kwe-600V (Umbane osetyenziswayo oqhelekileyo osetyenziswayo ngu-250V, osetyenziswa kwi-over-range kwi-380V, enobungozi obunokhuseleko).
●Uyilo oluphezulu lokhuseleko.I-socket ye-mains, isokhethi yokulinganisa i-voltage, igalelo langoku, igalelo le-clamp yangoku lilodwa, kunye ne-voltage yokumelana yi-4kV.
●Ukhuseleko lwamandla ombane wepulse.Xa i-voltage ephezulu ifaka i-voltage ngokuzenzekelayo iya kuqalisa ukhuseleko kwaye ibonise umyalezo okhawulezayo kwisixhobo, xa impazamo ilungisiwe, cofa kwi-interface ukuze usete kwakhona ukhuseleko.
●I-5A i-clamp inomsebenzi wokuzilungisa: i-signal ye-5A yangoku iveliswa ngaphakathi kwisixhobo esongeziweyo kwi-5A i-clamp ukulinganisa impazamo ye-clamp meter.
●Iichips ze-ARM ezi-5 zamandla aphantsi zisetyenzisiwe, bonke ubuchule bokubala bukhulu kune-1GIPS, kwaye zonke iiparamitha ze-harmonic ezingama-51 kunye ne-wave epheleleyo zibalwa ngaxeshanye.
●Ukusebenzisa inkqubo yokusebenza ye-Windows CE ekhulileyo kunye neyinyani, umsebenzi wayo uzinzile kwaye uthembekile.
| I-Voltage | Uluhlu lwempazamo yesiqinisekiso | 25-600V | |||
| Ukuqala ixabiso lokulinganisa | 0.5V | ||||
| Ixabiso elilinganisiweyo | 440V | ||||
| Ukuchaneka kwempazamo | ±0.05% | ||||
| Okwangoku | Indawo yokukhwelela | IkaliweIe | 5A | ||
| Uluhlu | 0.025A-12A | ||||
| Ukubamba | IkaliweIe | 5A, 100A, 500A,1000A(ukhetho) | |||
| Uluhlu | 0.5%Ie-2.4Ie | ||||
| Iqala ngoku | 0.02%Ie | ||||
| Uluhlu lwamaza okufakwayo | 45-65Hz | ||||
| Imposiso yokulinganisa rhoqo | ±0.01Hz | ||||
| Uluhlu lokulinganisa i-engile yesigaba | -180 ° - 180 ° | ||||
| Max.Impazamo ye-engile yesigaba | ±0.1° | ||||
| Ipesenti yeHarmonic, iiparamitha zombane ezihambelanayo, kunye namaxesha okulinganisa amandla ombane e-harmonic | 2-51amaxesha | ||||
| Ukubetha rhoqo (Phawula:Oko kukuthiIthelekelelwe yangoku) | Imveliso ephantsi(Iigiya ezi-3) | 5A | 3600P, 36000P, 360000P/kWh(kvarh, kVAh) | ||
| abanye | 3600P, 36000P, 360000P *(5/Ie)P/kWh (kvar, kVAh) | ||||
| Ubuninzi bangaphakathi obuphezulu | 5A | 1.8x109P/kWh | |||
| Ezinye iigiya zangoku | 1.8x109*(5/Ie)P/kWh | ||||
| Elona xesha liphezulu lokubetha kwe-pulse | 50kHz | ||||
| 5AIndawo yokukhwelela | Iliza elipheleleyo elisisisekokWh, P, U, I | ±0.05% | |||
| Iliza elipheleleyo elisisiseko Kvarh, Q, VA, Vha | ±0.2% | ||||
| HarmonicilizaU, I, P, Q, S | ±0.2%H(H=1+0.01k K=2-51) | ||||
| 5Aibamba | Iliza elipheleleyo elisisisekokWh, P, U, I | ±0.2% | |||
| Iliza elipheleleyo elisisiseko Kvarh, Q, VA, Vha | ±0.2% | ||||
| HarmonicilizaU, I, P, Q, S | ±0.5% H(H=1+0.01k K=2-51) | ||||
| Ukuzijonga ngokwangoku imveliso ye-cyclic yangoku | 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A | ||||
| Ubuquukujongaimpazamo (umahluko womgca kunye ne-angular) | ±0.1% | ||||
| I-clamp enkulu yangoku | Iliza elipheleleyo elisisisekokWh, P, U, I | ±0.5% | |||
| Iliza elipheleleyo elisisiseko Kvarh, Q, VA, Vha | ±0.5% | ||||
| HarmonicilizaU, I, P, Q, S | ±1.0% H(H=1+0.01k K=2-51) | ||||
| Abanye | Umlinganiselo womlinganiselo | ±0.5% | |||
| Impembelelo yombane | < ±0.01% | ||||
| Ukuphindaphindaimpembelelo | < ±0.01% | ||||
| Ubushushuimpembelelo | < ±0.005%/℃ | ||||
| Impazamo yokutshintsha iiyure ezingama-24 | < ±0.01% | ||||
| Harmonicimpembelelo | < ±0.01% | ||||
| Ibhetri etshajwayo | 11.1V 3000mAh | ||||
| Ukumelana nombane (Umlinganiselo wangoku weVoltage kunye nobonelelo lwamandla kunye neetheminali ezinombane ophantsi) | 4.0 kV | ||||
| UMbane oKhawuleza oQhusha ngokukhawuleza | 4.0 kV | ||||
| Surge | 4.0kV(Imowudi eqhelekileyo),2.0kV(imowudi eyahlukileyo) | ||||
| Ixesha lokulinda emva kokuqalisa | <3mzuzu | ||||
| Ubushushu obugciniwe | -25℃-+45℃ | ||||
| Ubuntu bezizalwane | 40%-95% | ||||
| Ukusebenza kombane | I-AC 55V - 600V | ||||
| Ukutya umbane | < 9W | ||||
| Ubungakanani | 275mm * 196mm * 78mm | ||||
| Ubunzima | < 1.5 kg | ||||

1--Touch screen
2--Ibar yenkqubo
3--Cima iqhosha
4--Phuma (ngasemva) isitshixo
5--Ikhibhodi
6--Tshintsha isitshixo
7--Iqhosha lesithuba
8--Navigation/ Kulungile iqhosha
9--Isokethi yamandla
10--Ukutshintsha amandla
I-11--Isokethi yokufakwa kwamandla ombane kwisigaba esithathu (ABC)
12--USB port
I-13--RS232 izibuko zokulungisa ujongano
14--Isokethi yokutshaja
15--Ukutshintsha ibhetri
17--Isibambi socingo esingundoqo esisixhenxe sesigaba se-A sokubamba ngoku
18--Isibambi socingo esingundoqo esisixhenxe sesigaba B sebamba langoku
19--Isibambi socingo esingundoqo esisixhenxe sesigaba se-C sokubamba sangoku
20--Ujongano lophawu lwePulse
21--Inqanaba legalelo langoku kunye nesokethi yemveliso
22--B isigaba segalelo langoku kunye nesokethi yemveliso
23--C isigaba segalelo langoku kunye nesokethi yemveliso
24--Iqhosha elijingayo
| Isilinganisi sommandla wemitha yeyure ye-watt yesigaba sesithathu | Iseti e-1 |
| I-100A yokujonga i-clamp | Iziqwenga ezi-3 |
| Iringi yokulungisa ibamba | Iqhekeza eli-1 |
| Intloko yombane wefoto df307 | Iqhekeza eli-1 |
| Idiski ye-USB (isoftware yolawulo) | Iqhekeza eli-1 |
| Umbane wesigaba esi-3 sombane ophezulu (kubandakanywa iqhosha kunye nephini) | Iqhekeza eli-1 |
| Isigaba esi-3 somgca wangoku (kubandakanya i-clamp kunye nokufaka) | Iqhekeza eli-1 |
| Umgca we-3 wesigaba se-pulse 1A | Iqhekeza eli-1 |
| Iadaptha | Iqhekeza eli-1 |
| Ikhodi yamandla | Iqhekeza eli-1 |
| Imitya | Iqhekeza eli-1 |
| Ibhokisi yesixhobo | Iqhekeza eli-1 |
| Incwadana yemveliso | Ikopi enye |
| isatifikethi seMveliso | Ikopi enye |
| Uluhlu lokupakisha lwefektri | Ikopi enye |
| Ingxelo yovavanyo lwasefektri | Ikopi enye |