I-GD2000H 10kV i-Insulation Resistance Tester
Esi sixhobo sinokuvavanya ukuchasana kwe-insulation (njenge-transformer, i-switchgear, i-lead, i-motor) yeemodyuli ezahlukeneyo kwinkqubo enye, ukugquma kunye nokulungisa amacandelo angaphumeleli.
Kubalulekile ukuqinisekisa umgangatho weemveliso kunye nokukhuseleka komntu kunye nezixhobo ngexesha lokusebenza ngovavanyo lokufakela ukukhangela into yokuvavanya phantsi okanye i-conductor ekufutshane.
Ngaphambi kombane kwisixokelelwano, sebenzisa uvavanyo lokugquma ukuqinisekisa ukuba kulungile ukuphucula ukusebenza kwenkqubo.Uvavanyo lwe-insulation kukufumana iingxaki zenkqubo yokuvelisa kunye nempazamo yezixhobo ezingafumanekiyo ngaphambi kokuba kwenzeke ukusilela.Kwi-EU, olu vavanyo lusisinyanzelo, nakwinkqubo yoluntu.
1. I-Voltage output GD2000H (5kV/10kV) .Uluhlu lokumelana 0-400GΩ.
2. Iimowudi ezimbini zibonisa ukumelana nokugquma.
3. I-auto-calculating absorption ratio kunye ne-polarization index.
4. Ukusebenza kobuhlobo, ukugcina ngokuqhubekayo iziphumo zomlinganiselo we-19times.
5. Ukuzikhupha ngokuzenzekelayo amandla ombane aphezulu aseleyo emva kokuba uvavanyo luphelile.
6. Umbane we-AC / DC, kunye nebhetri ehlaziywayo okanye i-adapter ye-AC.
7. Ikhono elinamandla lokuchasana nokuphazamiseka, ukufunda okuzinzileyo nokuthembekileyo.
8. Uyilo oluphathekayo, olulungele umsebenzi wasendle.
9. I-short-circuit current ≥3.5mA, izixhobo ezifanelekileyo zokuvavanya ukuxhatshazwa kwe-insulation ye-transformer enkulu, i-inductor, i-generator, i-HV motors, i-capacitor yombane, iintambo kunye ne-surge arrester.
IntoUmzekelo | GD2000H | ||
Imveliso yombane | 5kV DC | 10kV DC | |
Ukuchaneka | Ubushushu | 23℃±5℃ | |
Ukumelana ne-insulation | 5M ~ 100G ±5% | 10M ~ 200G ±5% | |
Olunye uluhlu: ±10% | |||
Imveliso yombane | 40M ~ 200G 0 ~ +10% | 80M-400GΩ 0 --+10% | |
Si-hort-circuit yangoku | ≥3.5mA | ||
Ukunikezwa Amandla | 8 *Uhlobo lwe-AA oluphezulu lwebhetri etshajwayo kunye neadaptha yangaphandle | ||
Ubushushu bokusebenza. & Nokufuma | -10℃--40℃,max.relative humidity 85% | ||
Ubushushu boGcino & nokufuma | -20℃--60℃,max.relative humidity 90% | ||
I-Insulation | Max.20000MΩ xa amandla ombane phakathi kwesekethe kunye neqokobhe yi-1000VDC. | ||
Ukumelana nombane | Ukumelana ne-1min xa amandla ombane phakathi kwesekethe kunye neqokobhe injalo3kV /50HzAC | ||
Ubungakanani | 230mm*190mm*90mm (L*W*H) | ||
Ubunzima | 3kg | ||
Izincedisi | Iikhokelo zovavanyo, i-manual, i-adapter etshajwayo, intambo yamandla, ingxelo yovavanyo |
Umvavanyi wokumelana ne-insulation | 1 iseti |
Ucingo lokuvavanya | Iqhekeza eli-1 |
Iadaptha yamandla | Iqhekeza eli-1 |
Ikhodi yamandla | Iqhekeza eli-1 |
Isikhokelo somsebenzisi | 1 ikopi |
Isatifikethi | 1 ikopi |