GDHX-9500 Phase Detector
I-GDHX-9500 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba kunye nesigaba sokulandelelana kolandelelwano kwi-substation, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa ukulandelelana kwesigaba.Isebenzisa ukhuseleko oluphindwe kabini kunye neesekethe ezintsha zedijithali, ezinokuphazamiseka okuchasene nokuphazamiseka, ngokuhambelana nemigangatho ye-EMC, ilungele iimeko ezahlukeneyo zokuphazamiseka kombane.
Umqondiso wesigaba esiphezulu sombane wenqanaba elilinganisiweyo liya kuhanjiswa ngokuthe ngqo emva konyango, i-handset iya kufumana kwaye yenze uthelekiso lwesigaba, inqume iziphumo emva kokufunyanwa kwesigaba, umboniso wexesha langempela umehluko we-angle ye-angle kunye ne-vector.Isebenzisa iteknoloji yokudlulisa i-wireless, ikhuselekile kwaye inokwethenjelwa , ngokukhawuleza kwaye ichanekile, ilungele ukusetyenziswa kumanqanaba ombane ahlukeneyo (6V-500KV).Xa uhlola isakhiwo segridi, siyakwazi ukuchonga ngokuchanekileyo isigaba esihambelanayo seendlela ezihlukeneyo zomgca odibeneyo wesigaba sesithathu, ngaphandle konxibelelwano lombane phakathi kwamacandelo amabini okulinganisa, okwenza ukusetyenziswa kwesixhobo sokulinganisa siguquguquke kakhulu kwaye sikhuselekile.
●Ukusebenzisa itekhnoloji yothumelo engenazingcingo, umgaqo wayo osisiseko wokusebenza kukuthelekisa ixesha lokwenyani.
●Nceda uqaphele kwaye ulandele ummiselo wokusebenzisa le mveliso, ukwenzela ukuba uqinisekise ukusebenza ngokukhuselekileyo kwesixhobo, iziphelo ze-X kunye ne-Y detector azivumelekanga ukuba zenze uvavanyo lombane.
●Iingxenye zentloko yentsimbi yentonga ye-insulating inqatshelwe ngokungqongqo ukudibana nazo naziphi na izinto ngexesha lovavanyo.
●Nceda uthobele imimiselo yokhuseleko loshishino lwamandla esizwe yovavanyo lokuthintela izixhobo zokhuseleko kunye neemveliso.
●Nceda unikele ingqalelo kuqeqesho kunye noviwo lwabasebenzi abasebenza kwimigca ephilayo ene-voltage ephezulu okanye kufutshane nemigca ephezulu yombane.
●Ukulinganisa inqanaba kwisixhobo esiphilayo kufuneka kuqhutywe ngentonga yokugquma.
Qaphela: Ubude obukhuselekileyo bokusetyenziswa kunye nemigangatho yovavanyo lwentonga yokugquma ye "Wireless Phase Detector".
(Kucatshulwe "kwimimiselo yokusebenza yokhuseleko loMbane yeState Grid Corporation".)
1. Umgama wokhuseleko phakathi kwabasebenzi kunye nomzimba ohlawuliweyo ngexesha lokusebenza okuphilayo.
| Inqanaba lombane | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
| Umgama woKhuseleko | 0.4M | 0.6M | 0.7M | 1.0M | 1.8M | 2.2M | 3.4M |
2. Ubuncinci obusebenzayo bokufakelwa kwentonga ngexesha lokusebenza okuphilayo.
| Inqanaba lombane | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
| Min.Ubude obusebenzayo bokugquma | 0.7M | 0.9M | 1.0M | 1.3M | 2.1M | 3.1M | 4.0M |
Qaphela: Umgangatho wovavanyo lovavanyo lokujonga izixhobo zokugquma (icandelwana): ukusebenzisa amandla frequency 75kV nganye 300mm nge-1min, ukuba akukho breakdown, akukho flashover kunye nobushushu obugqithisileyo, kuthathwa njengento efanelekileyo.
●Amandla ovavanyo: 10V-500kV, alungele inqanaba lombane elahlukileyo.
●Ukuchaneka: impazamo yokuzilinganisa ≤±3°.
●Isantya sesampuli: amaxesha angama-10 / s.
●Umhla kunye nexesha lokumisela: umhla kunye nohlengahlengiso lwexesha, kulula kubasebenzisi ukukhangela, ukujonga idatha yembali.
●Ukusetwa kwexesha lokukhanya ngasemva: ngokuqhelekileyo kuvuliwe, ngokuqhelekileyo kucinywe, i-0-999s inokusetwa ngumsebenzisi.
●Ukucima ukusetwa kwe-Auto: 0-999mins inokusetwa ngumsebenzisi.
●Kwinqanaba: ≤20 ° ithathwa njenge-in-phase (i-phase threshold ngaphakathi kwe-0-90 °, inokusetwa ngumsebenzisi. Ukungagqibeki kwenkqubo ngu-20 °.)
●Inqanaba elingaphandle komgangatho: > 20 ° (inqanaba lesigaba phakathi kwe-0-90 °, linokusetwa ngumsebenzisi. Ukusilela kwenkqubo ngu-20 °.)
●Umsebenzi wokulinganisa ummandla: ukulungelelaniswa kwendawo yokulinganisa ukhokelo, qinisekisa ukuchaneka kwe-angle yesigaba.
●Umgama wokudlulisa phakathi kwe-handset kunye ne-X, i-Y detector: X≤150m, Y≤150m.
●Uyilo lwemowudi ezininzi, kunye nokusebenza okuqinileyo, kukhuselekile kwaye kulula ngakumbi.
●Ujongano olulodwa lwabantu kwikhompyuter, umsebenzi olula.
●Uyilo lwe-antenna yeFCC, umqondiso womelele kwaye kulula ukungena ekuthinteleni udonga, umnyango, okanye umqobo.
●Ukukhusela kabini, ukuphazamiseka okunamandla kwe-an-ti, ngokuhambelana ngokupheleleyo nemigangatho ye-EMC.
●Iitshathi kunye nokuboniswa kwedatha, kulula ngakumbi kwaye kulula ukuyifunda.
●Umlinganiselo womgangatho, umboniso ngesandi kunye nomqondiso wokukhanya.
●Umlinganiselo wobungakanani, umboniso wexesha lokwenyani umahluko we-engile, impazamo≤5°.
●Ukulinganisa ulandelelwano lwesigaba, ulandelelwano lwesigaba esilungileyo, ulandelelwano lwesigaba esibi (120 °, 240 °).
| Uvavanyo lombane | 10V-500kV |
| Ukunikezwa Amandla | Iseti yesandla: No.5 AA ibhetri yealkaline amacandelo ama-2 (1.5V) |
| X kunye ne-Y detector: No.7 AA ibhetri yealkaline amacandelo ama-2 (1.5V) | |
| Umgama wothumelo olungenacingo | Umgama obonakalayo 150m |
| Kwinqanaba | Isigaba sokutenxa nge-engile≤20° (umda phakathi kwe-0-90°, unokusetwa ngumsebenzisi ngokwakhe. ) |
| Isigaba sangaphandle | Isigaba sokutenxa kwi-engile>20° (umda ophakathi kwe-0-90°, unokusetwa ngumsebenzisi ngokwakhe. ) |
| Bonisa ukuchaneka | Umlinganiselo wobungakanani≤3° |
| Isisombululo se-engile yesigaba | 1° |
| Umlinganiselo wolandelelwano lwesigaba | Ngokusebenzisa i-120° ngasekunene/240° ngokuchasene newotshi ukumisela nokubonisa ulandelelwano lwesigaba |
| Bonisa | Umboniso oncomekayo we-LCD, ubonisa ngokucacileyo phantsi kokukhanya kwelanga |
| Ubushushu bokusebenza | -35℃-+50℃ |
| Ubushushu bokugcina | -40℃-+55℃ |
| Ubuntu bezizalwane | ≤95%RH, Non-condensate |
| Iseti yesandla | 0.31kg |
| X detector | 0.13kg |
| Y detector | 0.13kg |