I-GDCF-900T yeMount yeSithuthi yeFault yokuFumana iNkqubo
Inkqubo yeNgqungquthela yeFault Mounted Cable isetyenziselwa ukulungiswa kweCable Fault (ukutshisa), iNdawo yangaphambili, indawo yeNdlela, iPin-pointing & Testing of HV & LV cables of different types&sizes.Iseti ifanelekile ukuphumeza oku kuchazwe ngasentla kwiintambo zombane zamanqanaba ombane ahlukeneyo ubukhulu becala i-33KV, 11KV, 415V kunye neentambo zokulawula ezinebakala le-1.1 KV.Iseti iya kusetyenziselwa iindidi zentambo ezizezi XLPE, PVC, PILC eneAl/Cu conductor.Iintambo zibekwe ngaphantsi komhlaba (phantsi komhlaba ongenanto, imisele, okanye umphezulu we-RCC, Ukugrunjwa okuHoliyo kwi-HDD Umbhobho), ngaphezu komhlaba okanye ngokuyinxenye ngaphantsi komhlaba kunye nenxalenye ngaphezulu komhlaba kunye nobude bekhebula lobuninzi malunga ne-25Km.
I-cable fault locator ifanelekile ukukhangela impazamo kunye nokukhomba ezi ntlobo zilandelayo zeempazamo zekhebula.
●Ukuchasana okuphezulu
●Ukuchasana okuphantsi
●Iimpazamo ezidanyazayo zodidi oluphakathi.
●Indawo ye-Sheath Fault
●Inkqubo isebenzisa ii-pulses ezininzi (i-ARC reflection method), i-pulses kathathu, indlela ye-impulse, indlela ye-flashover, indlela ye-TDR yokwenza umlinganiselo onzima wazo zonke iintlobo zeempazamo zekhebula.
●Isebenzisa indlela ye-acoustic magnetic ukufumana ngokuchanekileyo amanqaku eempazamo.
●Isebenzisa umgaqo wokungeniswa kwe-electromagnetic ukulandelela intambo engaziwayo kunye nokufumana ubunzulu bentambo.
●Chonga kwaye ugqobhoze iintambo ezininzi.
●Khangela kwaye ulinganise isheath yentambo.
Inkqubo yokuvavanya i-cable fault test yesithuthi isebenzisa uyilo olucwangcisiweyo kunye nolwabantu olubanzi ukufumana eyona mpazamo iphambili yokugquma i-33KV, i-11KV kunye ne-415V iintambo zamandla, ukuchongwa kwendawo enempazamo kwi-sheath yangaphandle, indawo echanekileyo yokumisela, uvavanyo lwendlela, ukuchongwa okuphilayo, ukuhlatywa kokhuseleko. , Ukuxhathisa kwe-DC ukuba zonke iintlobo zezixhobo zokuvavanya, izixhobo zokuhambisa amandla, izincedisi kunye nezixhobo ezincedisayo ezifunekayo zifakwe kwiimoto ezizodwa eziguqulwayo.
Yonke inkqubo yovavanyo ikhuselekile kwaye ivaliwe, kwaye imisebenzi yovavanyo iyahluka kwaye iziphumo zovavanyo zichanekile.
●Imoto inamacandelo amathathu: ikhebhu, igumbi lokusebenza kunye negumbi lezixhobo.
●Ubume bekhonsoli yokusebenza bufanelekile, kwaye uvavanyo lokugquma intambo, isigwebo sepropathi enempazamo, kunye nomgama ongalunganga wokulinganisa unokugqitywa ngokupheleleyo kwisithuthi.
●Umamkeli wovavanyo lwempazamo unokugqiba umlinganiselo orhabaxa womgama wecala lekhebula kwaye unokusibamba ngokuzenzekelayo isikhundla.
●Igumbi lokulawula liyilwe kunye necandelo elizimeleyo le-high-voltage high-voltage, i-LCD ibonisa ixesha langoku kunye ne-voltage, ngokuthe ngqo ngokuhlakanipha ukugqiba ukusebenza kwe-high-voltage kunye nokukhutshwa.
●Ukuchongwa kwentambo, umamkeli wovavanyo lwendlela ifakwe kwigumbi lokusebenza.
●Itafile yokusebenza yenziwe nge-epoxy resin ukwenza yonke into icoceke kwaye intle.Idrowa yesixhobo yenzelwe ukwenziwa kwentsimbi kunye nezitshixo zikaloliwe ezifunxa isandi.Yomelele, ayityibiliki, ayinxibi kwaye kulula ukuyikhuhla.Iqinisekisa ukhuseleko lwenkqubo yokuvavanya.
Ulwakhiwo lwangaphakathi
1——Indawo yokuqhuba
2——Indawo yokusebenza
3——Iyunithi yokulawula iziko
4——Ukulungiswa komqondiso onengxaki
5——Ikhabhathi yesixhobo sovavanyo lwesithuthi
I-6-- Iyunithi yokuvavanya i-high-voltage
7——Icandelo lokhuseleko
8——Ijenereyitha
9—— Uvavanyo lwentambo yombane oPhezulu
10——Intambo yentambo ephantsi
11——Udonga lokuba yedwa
Inkqubo yonke ibandakanya
Into | Igama | Umzekelo No. | Qty |
1 | Vehicle | -------------- | 1 |
2 | Multi-pulse cable fault tester | GD-4133 | 1 |
3 | I-Pulse coupler
| GD-4133S
| 1 |
4 | Cindawo enempazamo ekwaziyo
| GD-4132
| 1 |
5 | Hi-voltage impulse generator | GD-2131H
| 1 |
6 | Cisichongi esikwaziyo | GD-2134D
| 1 |
7 | Cisixhobo esikwaziyo sokugqobhoza | GD-2135B | 1 |
I-GD-2131H Impulse Generator
Isetyenziselwa ukuvelisa i-HV impulse xa usebenzisa indlela ye-impulse flashover ukukhangela impazamo ephezulu yokuphazamiseka.
●Ikhono elivuthayo elinamandla, ubuninzi.amandla avuthayo yi-1000W, indawo yokuphuka inokutshiswa ngexesha elifutshane kwaye ukuchasana kwendawo yokuphuka kuyancipha.
●Ukuba usebenza kunye ne-GD-4133 Cable Fault Tester, zimbini iindlela zokufumana indawo:
a.I-voltage ephantsi ye-pulse: Ukuba usebenzisa i-GD-4133 kuphela, isiphaluka esivulekileyo kunye neziphene ezisezantsi zokumisa intambo zinokufumaneka, kwaye ubude bentambo bunokulinganiswa, okanye isantya samaza sentambo sinokubonwa.
b.I-flashover yamandla ombane aphezulu: Ukukhupha i-pulse yamandla ombane kwindawo enempazamo ithathwa njengesampulu ngokukhupha umsantsa wesphere, onokuthi ufumane umgama wempazamo.
●Yenza impembelelo yefrikhwensi esisigxina.Ukuba usebenza kunye ne-GD-4132 Cable Fault Locator, kukho imisebenzi elandelayo:
a.Ukuphindaphinda komsindo: fumana i-impedance ephezulu, iimpazamo ezingaphaya kwamandla.
b.Ukukhomba indlela yentambo, chonga intambo ekhethekileyo.
c.Ukuqhekeka kwesinyithi (umhlaba ofileyo), usebenzisa umlinganiso wemagnethi ukuze ufumane ngokuchanekileyo.
●Inokusetyenziswa kwakhona kwi-DC HV yokumelana novavanyo.
●Ubonelelo lwamandla okufakwayo: AC 220V,50Hz
●Umbane ophumayo: DC 0-32kV (enokulungiswa)
●Amandla alinganisiweyo: 2kVA
●Max.amandla: 2048J, 4uF
●Umbane we-flashover ye-DC: 32kV
●I-DC flashover yangoku: 63mA
●Max.impembelelo yangoku: 500mA
●Indlela yokukhupha: I-DC HV, ixesha elinye, umjikelo
●Ixesha lokukhupha umjikelo: 3-6 imizuzwana
●Ubushushu bokusingqongileyo:0-40℃
●Ukufuma:<75% RH
●Ukuphakama: <1000m
●Inqanaba lokugquma: A
●Ubungakanani: 430 * 540 * 410mm
●Ubunzima: malunga ne-31kg.
GD-4132 iCable Fault Locator
Kubandakanya iyunithi ephambili, i-acoustic kunye ne-magnetic sensor, i-headphone ye-anti-ingxolo kunye neshaja.Kufanelekile ukuvavanya zonke iintlobo zentambo yamandla kunye ne-metallic conductor.Umsebenzi wayo ophambili kukufumana indawo yokugquma engalunganga, ukufumanisa isekethe kunye nobunzulu bentambo yamandla.
●I-Acoustic Magnetic ifumana ngaxeshanye
●Ubuchule obunamandla bokuchasana nokuphazamiseka
●Nge-headphone echasene nengxolo.
●320*240 LCD isiboniso sesikriniEyakhelwe ngaphakathi umthamo omkhulu weLi-ibhetri, enetshaja ekhawulezayo.
●Umboniso weAcoustic kunye neMagnetic waveform, umqondiso kunye nengxolo kulula ukwahlula.
●Ukusebenzisa ikhesa ukulinganisa ukulibaziseka kwe-acoustic kunye nemagnethi, chaza ngokuchanekileyo indawo enempazamo.Ngokuhambelana ne-polarity yokuqala ye-magnetic waveform, inokuyifumana kwaye ibonwe indlela.
1. Umsebenzi wokufumana
a.Ibhendi yokuhanjiswa komqondiso we-Acoustic: i-frequency center 400Hz, i-bandwidth 200Hz
b.Ukuzuzwa komqondiso: 80dB
c.Ukuchaneka kwendawo: 0.1m
2. Ubonelelo lwaMandla a.I-Li-ibhetri eyakhelweyo, i-voltage ye-nominal 7.4V, umthamo we-3000mAH.b.Ukusetyenziswa kwamandla: 300mA, ixesha eliqhubekayo lokusebenza 9hours.c.Itshaja: igaleloAC220V±10%, 50Hz.Imveliso yesiqhelo 8.4V,DC 1A d.Ixesha lokutshaja: iiyure ezi-4
3. Ubungakanani: 270mm * 150mm * 210mm
4. Ubunzima: 1.5kg.
5. Sebenzisa imeko Ubushushu -10℃--40℃, ukufuma 5-90%RH, ukuphakama <4500m
GD-4133 iCable Fault detector
I-GD-4133 iCable Fault Detectot isetyenziselwa ukulinganisa umgama phakathi kweempazamo zentambo.Kulula ukusebenza kunye nojongano olunobuhlobo.
Ingasetyenziswa yodwa phantsi kwemowudi ye-low voltage pulse.Ngaphantsi kwendlela ye-pulse yangoku, kufuneka isebenze kunye ne-GD-2131 ijeneretha yombane ophezulu.Ngaphantsi kwemowudi yepulse ezininzi, i-coupler ye-GD-4133S kufuneka isetyenziswe kunye.Emva kokufunyanwa komgama, i-GD-4132 fault locator kufuneka isetyenziswe ukukhomba iimpazamo.Ezi mveliso zinokudityaniswa kwiseti yokusebenza okuphezulu kunye nenkqubo yokuvavanya impazamo yentambo entsha.
●7inch LCD screen, interface friendly.
●Indlela yokufumana imigama emininzi:
Indlela ye-low-voltage pulse: ilungele ukufunyanwa kwempazamo ephantsi yokumelana, impazamo yesekethe emfutshane, impazamo yesekethe evulekileyo.Ikwanokusetyenziswa kumlinganiselo wobude bekhebula, amalungu aphakathi, amalunga e-T, kunye nejoyinti yokuphelisa intambo.Le ndlela ingasetyenziselwa ukulungisa isantya samaza.
Indlela ye-Pulse yangoku: Ifanelekile ukulinganisa umgama wesiphoso esiphezulu sokumelana, impazamo yokuphuka.Ukusebenzisa i-coupler yangoku ukuqokelela imiqondiso evela kucingo lomhlaba, yenza umsebenzisi abe kude kumbane ophezulu.Le ndlela ikhuselekile kwaye ithembekile.
Ukubetha kwentliziyo kaninzi: indlela ehambele phambili yokulinganisa umgama.I-waveform kulula ukuyichonga kwaye ukuchaneka kuphezulu.
●200MHz iisampulu yexesha langempela.Max.Isisombululo somlinganiselo we-0.4m.Inommandla omncinci ofileyo kwaye ikhethekileyo kwintambo emfutshane kunye nekhebula elikufutshane.
●Chukumisa isikrini kwaye ucinezele ukusebenza kweqhosha
●Ikopi yePIP (pic. ugcino lwexeshana)
●Kuya kubakho ifestile ephambili kunye neefestile ezintathu zokugcina okwethutyana zinokujonga iifom ezintathu zamaza kunye.
●Inkqubo yokusebenza eyakhelweyo
Ulawulo olukhethekileyo lwesoftware yokuphucula isoftware, i-backup kunye nokubuyisela.
●Umsebenzi wesikali
Indawo yokuqala, abafowunelwa abali-10, impazamo enye yentambo kunye nobude obunye obupheleleyo bunokusetwa.
Bonisa isikali kunye novavanyo lwamaza kunye
●Ukugcinwa kweWaveform kunye nonxibelelwano kunye nekhompyuter.
Ukugcinwa kwangaphakathi kweefom zamaza.
Nge-USB, ukukhuphela okanye ukulayisha idatha
Unxibelelwano ngekhompyuter
●Ulawulo lwamandla
Isibane sangasemva sibuthathaka ukuba akukho msebenzi kwi-2mins kunye nokucima amandla kwi-10mins ukuba akukho msebenzi.
Ibhetri eyakhelwe-ngaphakathi yePolymer Lithium-ion.
Ixesha lokusebenza lifikelela kwiiyure ezi-5 kusetyenziso ngalunye.
Ityala eliqinileyo, kulula ukuthwala.
Iindlela zokukhangela | Indlela yempembelelo yombane ophantsi Indlela yangoku yempembelelo Indlela yempembelelo emininzi ukuba ihambelana ne-GD-4133S |
Max.Isampulu frequency | 200MHz |
Ukufumana uluhlu | 0-70dB |
Umbane ophantsi we-impulse voltage | 30V |
Max.isisombululo | 0.4m |
Max.Indawo yoluhlu | 100km |
Indawo efileyo | 2m |
Ibhetri | Iibhetri zeNickel-metal hydride ezitshajwayo, ixesha lokunyamezela ngaphezulu kweeyure ezi-5 |
Ujongano lonxibelelwano | i-USB |
Ukunikezwa Amandla | Igalelo AC220V,50Hz,i-2A yangoku,intlawulo yeeyure ezisi-8 |
Dim. | 274×218×81mm |
Ubunzima | 3.5kgs |
Ubushushu bokusebenza | -10℃-40℃ |
Ukufuma | 5-90%RH |
Ukuphakama | <4500m |
GD-4133S Multiple Pulse Coupler
Isebenza kunye ne-GD-4133 yeCable Fault Detector, esetyenziselwa ukufumanisa impazamo yokuvuza okuphezulu kwe-impedance, i-flashover fault, i-impedance ephantsi yomhlaba kunye neempazamo zesekethe evulekileyo yeentambo zamandla.I-GD-4133S ibonelele nge-pulse coupling signal ye-GD-4133 kwaye ihlukanise kwizixhobo zombane ophezulu.
●Ukusebenzisa ubuchwephesha obukwinqanaba eliphezulu lemiphunga emininzi kunye nokulingana kwepulse.Kukho imo yamaza ebonakalisiweyo kulula ngakumbi ukuyichonga.
●Ngokhuseleko lwe-HV yokhuseleko, isekethe yokulinganisa kunye namandla ombane aphezulu we-impulse power ibekwe yodwa ngombane.
●Iingcingo ezilula, ezikhuselekileyo nezithembekileyo.
Iinkcukacha
●Umbane wePulse: 300V(PP)
●Igalelo lamandla ombane wempembelelo: <35kV
●Igalelo elivumelekileyo lamandla empembelelo: <2000J
●Igalelo lamandla: 220VAC, 50Hz
●Ubungakanani: 560 * 230 * 220mm
●Ubunzima: 7kg.
GD-2134D Isichongi seCable
Isichongi seCable ye-GD-2134D siquka isidluliseli kunye nomamkeli, sinokusetyenziselwa ukukhangela umkhondo kunye nobunzulu beentambo eziphantsi komhlaba kunye nemibhobho yesinyithi, kananjalo ukuchonga intambo kwintlaninge yeentambo.
●Bonisa ngokuthe ngqo indawo yombhobho.
●Utolo olubonisa indlela ekhohlo/ekunene yokuJonga indlela yeCable.
●Ixesha langempela lokulinganisa umbhobho ulwalathiso lwangoku kunye nobuxoki / ukukhawuleza okuchanekileyo phantsi kobuninzi bexesha.
●Isibonisi esichanekileyo/esingeyonyani.Iya kukhomba phambili xa ikhebula elichongiweyo lilandelwa ngokuchanekileyo.Ngaphandle koko, iya kukhomba ngasemva kwaye iya kubonisa "?".
●Ukulinganisa okuzenzekelayo kobunzulu kunye nangoku.
●Ukuchongwa kwentambo: Ukuchongwa kweclamp kunye nokuchongwa kwestethoscope.Ukuchongwa kweclamp kunokulinganisa i-amplitude yangoku kunye nesikhokelo sentambo ngokuchanekileyo kwaye inike iziphumo ezichanekileyo.Ukuchongwa kweStethoscope yindlela yesintu xa ingafanelekanga ukusebenzisa uchongo lweClamp.Kulucingo olulula ukuchongwa kweStethoscope.
●Ukusebenzisa i-rack (isincedisi ozikhethelayo) ukufumana indawo yempazamo yokugquma komhlaba.Akuyimfuneko ukulungelelanisa kwindawo ye-zero.Utolo lubonisa icala lendawo enempazamo.
●I-digitalization epheleleyo yesampuli ephezulu echanekileyo kunye nokucubungula, kunye nebhendi yokwamkela emxinwa kunye nokuphazamiseka okunamandla.Icinezela ngokupheleleyo ukuphindaphindwa kwamandla kunye nokuphazamiseka kwe-harmonic kwiintambo ezisebenzayo ezikufutshane.
●Ubhaqo olusebenzayo kunye nobhaqo lokwenziwa.
●Eyakhelwe ngaphakathi umthamo omkhulu Ibhetri yeLithium.Ukucima umbane ngokuzenzekela xa i-voltage ingaphantsi okanye ingasebenzi ixesha elide.
Isidluliseli
●Imveliso (imowudi ezintathu): Uqhagamshelo oluthe ngqo oluphumayo, ukuphuma kweClamp Coupling (ukhetho), ukufakwa kweRadiation.
●I-Frequency (6 yokuzikhethela): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, kuquka i-640Hz kunye ne-1280Hz i-frequency complex.Iyakwazi ukuqaphela umsebenzi weSibonakaliso esiLungileyo / esingeyonyani kunye nokuchongwa kombhobho ngoncedo lwe-Receiver.
●Isiphumo sophawu lwesiphoso ukubona isiphene sokumisa uMbhobho.
●Imveliso yamandla: Max.10W, 10steps adjustable.
●Umbane ophumayo woqhagamshelwano oluthe ngqo: Max.150Vpp.
●Ukuthelekisa okuzenzekelayo kunye nemisebenzi yomthwalo ogqithisileyo kunye nokhuseleko lwesekethe emfutshane.
●Ukunikezelwa kwamandla: Ibhetri yeLithium ehlaziywayo yangaphakathi, i-4pcs, imodeli no.18650.ngegama 7.4V, 6.8Ah.
●Yomelele kwaye iyaphatheka.
Umamkeli
●Imowudi yokufaka: ikhoyili yokufumana eyakhelwe-ngaphakathi, i-clamp yokufumana (ukhetho), i-echometer(ukhetho), i-rack(ukhetho).
●Iibhendi ezimbini zefrikhwensi yokufumanisa: amandla frequency kunye nerediyo frequency (RF).Akukho mfuneko yokunxibelelana nejenereyitha yomsindo.
●Ukufumana rhoqo:
Ukufunyanwa rhoqo okusebenzayo: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
I-PF yokubona i-frequency ye-passive: 50/60Hz kunye ne-250/300Hz (umsebenzisi oqwalaselweyo)
I-RF i-passive yokufumanisa i-frequency: i-frequency ye-central frequency yi-10kHz, i-33kHz, i-83kHz ngokulandelelanayo.
●Imowudi yokukhangela: indlela encopho, indlela emxinwa, indlela engenanto.
●320*240 pixel LCD screen.
●Ibhetri ye-lithium eyakhelwe-ngaphakathi, i-2pcs 18650 Li ibhetri, i-nominal.7.4V, i-3.4Ah.
●Yomelele kwaye iyaphatheka.
Ezinye iinkcukacha
●Ubungakanani: i-transformer 270 * 220 * 85mm, ummkeli 700 * 270 * 120mm.
●Ubunzima: umthumeli 2.2kg, umamkeli 2.2kg.
●Itshaja: igalelo AC 100-240V, 50/60Hz, imveliso DC 8.4V, 2A.
●Imeko yokusebenza: Ubushushu -10--40 ℃.Ukufuma 5-90% RH, Ukuphakama<4500m.
Isixhobo se-GD-2135 Cable Puncture
I-GD-2135B iCable Puncture Device ikwasisichongi sentambo, ukuchonga intambo evela kwiqela leentambo.
Sisixhobo sokubhoboza esikhuselekileyo esingaqhagamshelwanga, esinolawulo olukude kunye nexesha.
Esi sixhobo sibandakanya iinxalenye ezimbini, isixhobo sokubethelela kunye nesixhobo sokulawula.Isebenza ngebhetri, ekwahlula isixhobo sokugqobhoza kwinkqubo yamandla, ukuqinisekisa ukhuseleko lonikezelo lwamandla.
●Ilungele ukubhoboza zonke iintlobo zentambo yamandla, ikhuselekile kwaye ithembekile.
●Iindlela ezimbini zokusebenza, kubandakanya ukude kunye nexesha.Amaqhosha amabini aza kusetyenziselwa ukungena kwimodi yokusebenza, qinisekisa ukhuseleko lomsebenzisi.
●Amaqhosha amabini akude (iqhosha C kunye no-D licofe ngaxeshanye).Ukuqinisekisa ukufumana okuthembekileyo, i-eriyali yothumelo yolawulo olukude kufuneka itsalwe ngaphandle ngokupheleleyo.
●Ukusebenzisa imipu ephindwe kabini ukugqobhoza ngee-engile ezimbini.Umsebenzi omnye wokuvavanya ukugqiba iipunctures ezimbini.
●Nge-alam yesandi kunye nomboniso we-LCD.
●Uyilo lokhuseleko oluninzi ngabakhandi kunye nombane.
●Ekhethekileyo eyenzelwe i-cable puncturing, igxininiswe ngokuthe ngqo kwikhebula, efakwe kuyo nayiphi na i-angle.
●Ukusebenzisa amandla ebhetri, alungele ukusetyenziswa endle ngaphandle kombane.Kwakhona, ihlukanisa isixhobo sokubhoboza kwinkqubo yamandla, ukuqinisekisa ukhuseleko.
●Wireless umgama kude: ≤ 20M.
●Ukusetyenziswa kwentambo: zonke iintambo zamandla ≤ ¢125mm
●Amandla okusebenza: 6pcs 1.5V ibhetri.
●Imeko yokusebenza: ubushushu -10--50 ℃, ukufumaRH<95%.
●Ubunzima: 15kg kuquka i-aluminium case.
●Ubungakanani: 48 * 45 * 16cm