I-GD-4138H yeNkqubo yokuLawula iCable Fault
GD-4138H Mobile Cable Fault Locating System sisixhobo esibalulekileyo ukugcina zonke iintlobo zeentambo.Sisixhobo esihambelanayo esinokuthi silandele, sifumane iintambo eziphantsi komhlaba, ezinomlinganiselo wempazamo kunye nokuveliswa kwe-HV.Njengoko sisixhobo esishukumayo, kukulungele ukusiqhuba kwisiza.Ukuba i-acoustic locator isetyenziswa kunye, inokufumana indawo echanekileyo yendawo yempazamo yentambo.
Isicelo yintambo engaphantsi komhlaba, intambo yasemoyeni, intambo yamandla, intambo yendawo, intambo yonxibelelwano kunye nentambo yefayibha.
●Impazamo ephezulu ye-impedance flash-over fault
●Ukuvuza okuphezulu kwe-impedance
●Umgangatho ophezulu/ophantsi oxhathisayo
●Impazamo yexesha elifutshane
●Impazamo evulekileyo yesekethe
●Uqhagamshelo olulambathayo/Uqhawulo
●Isakhelo esingundoqo se-GD-4138H (Isixhobo sokuDityana, isithuba seSphere, ijenereyitha yeHV ingaphakathi)
●GD-4133 Isivavanyi sempazamo yentambo yepulse ezininzi
●GD-4132 iCable Fault Locator
●Iindlela ezininzi ezihlukeneyo: indlela ye-low-voltage ye-pulse, indlela ye-pulse yangoku, indlela ye-pulse multiple: isampuli yangoku, i-DC output.
●Iindidi zesampulu zesampulu: Indlela yokubonakalisa i-arc ye-DC, isampulu yangoku, isampulu yombane, i-low voltage pulse.
●Khangela ngokukhawuleza kwaye ukhombise ukuxhathisa okuphantsi, ukuxhathisa okuvuza okuphakamileyo kunye neempazamo ze-flashover ezahlukeneyo ze-220V-220KV iintambo zamandla ombane webakala.
●Akukho mfuneko yokwenzaiingcingo ezintsonkothileyo zovavanyo lwendawo.Zonke iindlela zovavanyo zitshintshwa ngokuzenzekelayo ngokusebenzisa iswitshi yangaphakathi yombane ophezulu olawulwa ngumbane obuthathaka.
●Integrated multi-speed DC high-voltage generator, multi-speed high-voltage capacitor, iyunithi arc ukuzinzisa kunye nokufunyanwa umqondiso ezahlukeneyo kwenye, lula ukusebenza inkqubo indawo fault.
●Ukutshintsha kwamanqanaba amaninzi ombane aphezulu, zonke zilawulwa ngumbane ophantsi wangaphakathi obuthathaka, ukhuselekile kwaye uthembekile.
●Isakhiwo sezixhobo samkela ityala leplastiki eliphezulu.Ityala yibhokisi yangaphandle yezixhobo kunye nebhokisi yokudlulisa iphakheji yokuhanjiswa kwezixhobo.Kukulungele ukudlulisa, kwaye inokulayishwa kwaye idluliselwe ngokuthe ngqo xa i-cover ivaliwe.
●I-Sphere gap impulse discharge: Ubuthathaka bolawulo lwangoku lwe-solenoid valve air gap, ixesha lokukhutshwa lilungelelaniswa ukusuka kwi-3 ukuya kwi-12 imizuzwana, kwaye i-muffler yenzelwe ngokukodwa ukuhlangabezana neemfuno zesimumu sokungaphumeleli kwentambo ekuqaleni.
●Isixhobo sinesekethe yokukhupha eyakhelweyo.Emva kokuba uvavanyo lwempazamo lugqityiwe, i-voltage ephezulu inokuvalwa cinezela iqhosha kwindawo yokukhupha ukuze ukhuphe ngokuzenzekelayo.
●Umamkeli wokulinganisa umgama unokubonelela ngesisombululo sokulinganisa umgama ukuya kwi-0.4m, kwaye indawo eyimfama yokulinganisa incinci, esebenza ngokukodwa kwiimpazamo ezikufutshane kunye neentambo ezimfutshane.
●Zonke ii-terminals zemveliso zezixhobo zicwangciswe kwipaneli yangasemva ukwenzela ukuba kube lula, kunye nemizobo ye-wiring yeendlela ezahlukeneyo zocingo zizotywa kwipaneli yokusebenza, enokusetyenziswa lula ngabantu abangenamava.
●I-bottom of the equipment ixhotyiswe ngamavili e-sliding 4 aphezulu, anokuthi atyhalwe kwaye afakwe kwisitoreji.
●Umninimzi oqalayo usebenzisa i-7-intshi ye-LCD yesikrini esikhulu kunye ne-angle yokujonga i-160 °, kunye nomxholo wokubonisa ucebile kwaye unembile.
●Inani elikhulu leefomati zamaza linokugcinwa kwinginginya, kwaye idatha ye waveform inokungeniswa ngaphandle kwaye ithunyelwe ngaphandle kusetyenziswa U disk.
●Umamkeli unokuqhagamshelwa kwikhompyuter (idesktop okanye incwadi yokubhalela) kunxibelelwano lwe-intanethi.
●Xa umninimzi engenamsebenzi ngaphakathi kwemizuzu emi-2, i-backlight iya kuba buthathaka;ukuba akukho msebenzi wemizuzu eyi-10, iya kuvala ngokuzenzekelayo ukunciphisa ukusetyenziswa kwamandla;xa ibhetri ingenawo amandla ombane, isixhobo siya kuzivala ngokuzenzekelayo ukukhusela ibhetri.
●Umninimzi unebhetri ye-polymer ye-lithium-ion eyakhelwe ngaphakathi kwaye ixhotyiswe ngeshaja yebhetri ye-lithium ezinikeleyo ukubonelela ngendlela ethembekileyo yokutshaja.
●Lo matshini uphela wamkela uyilo oludityanisiweyo loyilo lwesakhiwo sebhokisi, ecwengileyo kwaye iqinile, ilungele ukusetyenziswa kwendawo yokwakha.
Umzekelo | GD-4138L | GD-4138M | GD-4138H |
Imo yovavanyo | Indlela yokubonakalisa iArc, isampuli yangoku, imveliso yeDC | Indlela yokubonakalisa i-Arc, indlela yokubonakalisa i-arc ye-DC, isampuli yangoku, imveliso ye-DC | |
Uhlobo lophawu lwesampulu ephakathi | Iindlela ezininzi zokubonisa i-arc ye-pulse, isampuli yangoku, i-low voltage pulse | Indlela yokubonakalisa i-Arc, indlela yokubonakalisa i-arc ye-DC, isampuli yangoku, imveliso ye-DC | |
Imveliso ye-DC HV | 0~16KV polarity embi Ubuninzi bemveliso yangoku: 152mA | 0~32KV polarity embi Ubuninzi bemveliso yangoku: 76mA | 0~8KV negative polarity Ubuninzi bemveliso yangoku: 304mA 0~16KVnegative polarity Ubuninzi bemveliso yangoku: 152mA 0~32KVnegative polarity Ubuninzi bemveliso yangoku: 76mA |
Umthamo weFlashover | 0-16kV 8μF Ubuninzi bamandla aphumayo: 1024J | 0-32kV 4μF Ubuninzi bemveliso yamandla: 2048J | 0-8kV 32μF Ubuninzi bamandla aphumayo: 1024J 0-16kV 8μF Ubuninzi bamandla aphumayo: 1024J 0-32kV 4μF Ubuninzi bemveliso yamandla: 2048J |
Ukukhutshwa komsantsa we-automatic sphere | Ubuthathaka bolawulo lwangoku lwe-solenoid valve gap emoyeni, ixesha lokukhutshwa lilungelelaniswa ukusuka kwi-3 ukuya kwi-12 imizuzwana, kwaye i-muffler yenzelwe ngokukodwa ukuhlangabezana neemfuno zesimumu sokungaphumeleli kwentambo ekuqaleni. | ||
Imo yokuphuma | I-DC imelana nombane, ukukhutshwa okukodwa, ukukhutshwa ngamaxesha | ||
I-DC imelana nombane | 16KV | 32KV | 32KV |
Igalelo lamandla ombane wempembelelo | 16kV | 32kV | 32kV |
Igalelo elivumelekileyo lamandla empembelelo | <2048J | ||
Indawo yokusebenza | Ubushushu: 0 ~ 40℃ Ukufuma okunxulumeneyo: <75%RH | ||
Ukunikezwa Amandla | AC220V, 50Hz | ||
Umthamo opheleleyo | 3kVA |
Isetyenziselwa ukulinganisa impazamo yomgama.Ngaphantsi kwe-LV pulse mode, inokusetyenziswa yodwa.
7inch LCD screen, interface friendly.
Indlela yokufumana imigama emininzi:
Indlela ye-low-voltage pulse: ilungele ukufunyanwa kwempazamo ephantsi yokumelana, impazamo yesekethe emfutshane, impazamo yesekethe evulekileyo.Ikwanokusetyenziswa kumlinganiselo wobude bekhebula, amalungu aphakathi, amalunga e-T, kunye nejoyinti yokuphelisa intambo.Le ndlela ingasetyenziselwa ukulungisa isantya samaza.
Indlela ye-Pulse yangoku: Ifanelekile ukulinganisa umgama wesiphoso esiphezulu sokumelana, impazamo yokuphuka.Ukusebenzisa i-coupler yangoku ukuqokelela imiqondiso evela kucingo lomhlaba, yenza umsebenzisi abe kude kumbane ophezulu.Le ndlela ikhuselekile kwaye ithembekile.
Ukubetha kwentliziyo kaninzi: indlela ehambele phambili yokulinganisa umgama.I-waveform kulula ukuyichonga kwaye ukuchaneka kuphezulu.
200MHz iisampulu yexesha langempela.Max.Isisombululo somlinganiselo we-0.4m.Inommandla omncinci ofileyo kwaye ikhethekileyo kwintambo emfutshane kunye nekhebula elikufutshane.
Chukumisa isikrini kwaye ucinezele ukusebenza kweqhosha.Ikhesa inokutsalwa.
Ikopi yePIP(pic. ugcino lwexeshana)
Kuya kubakho ifestile ephambili kunye neefestile ezintathu zokugcina okwethutyana zinokujonga iifom ezintathu zamaza kunye.
Indlela yokusebenza eyakhelwe-ngaphakathi
Ulawulo olukhethekileyo lwesoftware yokuphucula isoftware, i-backup kunye nokubuyisela.
Umsebenzi wesikali
Indawo enye yokuqala, abafowunelwa abali-10, impazamo enye yekhebula kunye nobude obupheleleyo obunye bunokusetwa.
Bonisa isikali kunye novavanyo lwamaza ngaxeshanye
Ukugcinwa kweWaveform kunye nonxibelelwano kunye nekhompyuter.
Ukugcinwa kwangaphakathi kweefom zamaza.
Nge-USB, ukukhuphela okanye ukulayisha idatha
Unxibelelwano ngekhompyuter
Ulawulo lwamandla
Isibane sangasemva sibuthathaka ukuba akukho msebenzi kwi-2mins kunye nokucima amandla kwi-10mins ukuba akukho msebenzi.
Ibhetri eyakhelwe-ngaphakathi yePolymer Lithium-ion.
Ixesha lokusebenza lifikelela kwiiyure ezi-5 kusetyenziso ngalunye.
Ityala eliqinileyo, kulula ukuthwala.
Iindlela zokukhangela | Indlela yempembelelo yombane ophantsi Indlela yangoku yempembelelo Iindlela ezininzi zempembelelo |
Max.Isampulu frequency | 200MHz |
Ukufumana uluhlu | 0-70dB |
Umbane ophantsi we-impulse voltage | 30V |
Max.isigqibo | 0.4m |
Max.Indawo yoluhlu | 100km |
Indawo efileyo | 2m |
Ibhetri | Iibhetri ze-nickel-metal hydride ezitshajwayo, ixesha lokunyamezela kwiiyure ezi-5 |
Ujongano lonxibelelwano | i-USB |
Ukunikezwa Amandla | Igalelo le-AC220V, i-50Hz, i-2A yangoku, intlawulo yeeyure ze-8 |
Dim. | 274×218×81mm |
Ubunzima | 3.5kg |
Ubushushu bokusebenza | -10℃-40℃ |
Ukufuma | 5-90%RH |
Ukuphakama | <4500m |
●Isignali ye-acoustic kunye nemagnethi ifunyenwe ngexesha elifanayo.Ubuchule obunamandla bokuchasana nokuphazamiseka.
●Umboniso wamaza.
●Umboniso we-acoustic magnetic waveform.
●Ukufumana indawo enempazamo kunye nokulandela indlela.
●Ngeearphone ukuva ingxolo.
●320*240 LCD isiboniso sesikrini, ujongano olunobuhlobo.
●Ibhetri ye-Li eyakhelwe-ngaphakathi, enetshaja ekhawulezayo.
●Iyakucima ngokuzenzekelayo ukuba ayisebenzi emva kwe-15mins okanye ibhetri ephantsi.
●Ubungakanani obuncinci, kulula ukuthwala.
●I-Acoustic signal bandwidth: i-centre frequency 400Hz, i-bandwidth 200Hz
●Inzuzo yomqondiso: 80db.
●Ukuchaneka kwendawo: 0.1m
●Ukunikezelwa kwamandla: ibhetri ye-Li eyakhelwe ngaphakathi, i-voltage ye-7.4V, i-3000mAh, i-9hours eqhubekayo yokusebenza.
●Itshaja: Igalelo AC220V±10%, 50Hz, imveliso yegama 8.4V, DC1A
●Ixesha lokutshaja: <4 iiyure
●Ubungakanani: 270 * 150 * 210mm.
●Ubunzima: 1.5kg.
●Isimo sokusetyenziswa: ubushushu -10--40 ℃, ukufuma 5-90%RH, ukuphakama <4500m.