I-GD-4136H yeNkqubo yokuLawula iCable Fault
Inkqubo yeFault yeCable ye-GD4136H sisixhobo esibalulekileyo sokugcina zonke iintlobo zeentambo.Isebenzisa iindlela ezahlukeneyo zokubona ukuvavanya iimpazamo zentambo, ezifanelekileyo kumanqanaba ahlukeneyo iintambo zamandla ombane kunye neentambo zonxibelelwano.
Inkqubo iqulathe ngezantsi iiyunithi:
I-1.GD-2131H i-Impulse Generator
2.GD-4132 iCable Fault Locator
3.GD-4133 Multi-pulse Cable Fault Detector
I-4.GD-4133S i-Multi-pulse Coupler
5.Ezinye izincedisi
I-GD-2131H Impulse Generator

Isetyenziselwa ukuvelisa i-HV impulse xa usebenzisa indlela ye-impulse flashover ukukhangela impazamo ephezulu yokuphazamiseka.
●Ikhono elivuthayo elinamandla, amandla okushisa aphezulu yi-1000W, ukuchithwaindawo inokutshiswa ngexesha elifutshane kwaye ukuchasana kwendawo yokuphuka kuyancipha.
●Ukuba usebenza kunye ne-GD-4133 Cable Fault Tester, zimbini iindlela zokufumana indawo:
a.I-voltage ephantsi ye-pulse: Ukuba usebenzisa i-GD-4133 kuphela, isiphaluka esivulekileyo kunye neempazamo ezisezantsi zokumisa ikhebula zinokufumaneka, kwaye ubude bentambo bunokulinganiswa okanye isantya samaza sentambo sinokubonwa.
b.I-flashover yamandla ombane aphezulu: Ukukhupha i-pulse yamandla ombane kwindawo enempazamo ithathwa njengesampulu ngokukhupha umsantsa wesphere, onokuthi ufumane umgama wempazamo.
●Yenza impembelelo yefrikhwensi esisigxina.Ukuba usebenza kunye ne-GD-4132 Cable Fault Locator, kukho imisebenzi elandelayo:
a.Ifrikhwensi yomsindo: fumana i-impedance ephezulu, iimpazamo ze-flash-over.
b.Ukukhomba indlela yentambo, chonga intambo ekhethekileyo.
c.Ukuqhekeka kwesinyithi (umhlaba ofileyo), usebenzisa umlinganiso wemagnethi ukuze ufumane ngokuchanekileyo.
●Inokusetyenziswa kwakhona kwi-DC HV yokumelana novavanyo.
●Ubonelelo lwamandla okufakwayo: AC 220V, 50Hz
●Umbane ophumayo: DC 0-32kV (enokulungiswa)
●Amandla alinganisiweyo: 2kVA
●Max.energy: 2048J, 4uF
●Umbane we-flashover ye-DC: 32kV
●I-DC flashover yangoku: 63mA
●I-Max.impulse yangoku: 500mA
●Indlela yokukhupha: I-DC HV, ixesha elinye, umjikelo
●Ixesha lokukhupha umjikelo: 3-6 imizuzwana
●Ubushushu bokusingqongileyo:0-40℃
●Ukufuma:<75% RH
●Ukuphakama: <1000m
●Inqanaba lokugquma: A
●Ubungakanani: 430 * 540 * 410mm
●Ubunzima: malunga ne-31kg.
Kubandakanya iyunithi ephambili, i-acoustic kunye ne-magnetic sensor, i-headphone ye-anti-ingxolo kunye neshaja.
Kufanelekile ukuvavanya zonke iintlobo zentambo yamandla kunye ne-metallic conductor.
Umsebenzi wayo ophambili kukufumana indawo yokugquma engalunganga, ukufumanisa isekethe kunye nobunzulu bentambo yamandla.

●I-Acoustic Magnetic ifumana ngaxeshanye.
●Ubuchule obunamandla bokuchasana nokuphazamiseka.
●Nge-headphone echasene nengxolo.
●320*240 LCD umboniso wesikrini.
●Eyakhelwe ngaphakathi umthamo omkhulu weLi-ibhetri, enetshaja ekhawulezayo.
●Umboniso weAcoustic kunye neMagnetic waveform, umqondiso kunye nengxolo kulula ukwahlula.
●Ukusebenzisa ikhesa ukulinganisa ukulibaziseka kwe-acoustic kunye nemagnethi, chaza ngokuchanekileyo indawo enempazamo.
●Ngokuhambelana ne-polarity yokuqala ye-magnetic.waveform, ingafumana indawo kunye nokufunyanwa kwendlela.
1. Umsebenzi wokufumana
a.Ibhendi yokuhanjiswa komqondiso we-Acoustic: i-frequency center 400Hz, i-bandwidth 200Hz
b.Ukuzuzwa komqondiso: 80dB
c.Ukuchaneka kwendawo: 0.1m
2.Unikezelo lwaMandla
a.I-Li-ibhetri eyakhelweyo, i-voltage ye-7.4V, umthamo we-3000mAH.
b.Ukusetyenziswa kwamandla: 300mA, ixesha eliqhubekayo lokusebenza 9hours.
c.Itshaja: igalelo AC220V±10%, 50Hz.Imveliso yeNominal 8.4V, DC 1A
d.Ixesha lokutshaja: iiyure ezi-4
3. Ubungakanani: 270mm * 150mm * 210mm
4. Ubunzima: 1.5kg.
5. Sebenzisa imeko
Ubushushu -10℃--40℃, ukufuma 5-90%RH, ukuphakama <4500m

I-GD-4133 iCable Fault detector isetyenziselwa ukulinganisa
umgama phakathi kweempazamo zentambo.Kulula uku
ukusebenza kunye nojongano olunobuhlobo.
Ingasetyenziswa yodwa phantsi kwemowudi ye-low voltage pulse.U
phantsi kwendlela ye-pulse yangoku, kufuneka isebenze kunye ne-GD-2131
ijenereyitha yombane ophezulu.Ngaphantsi kwemodi ye-pulse ezininzi, i-GD-4133S
I-coupler kufuneka isebenze kunye.Emva kokufunyanwa komgama, i-GD-4132 fault locator kufuneka isetyenziswe ukukhomba iimpazamo.Ezi mveliso zinokudityaniswa zibe
iseti yokusebenza okuphezulu kunye nenkqubo yokuvavanya impazamo yentambo entsha.
●7inch LCD screen, interface friendly.
●Indlela yokufumana imigama emininzi:
Indlela ye-low-voltage pulse: ilungele ukufunyanwa kwempazamo ephantsi yokumelana, impazamo yesekethe emfutshane, impazamo yesekethe evulekileyo.Ikwanokusetyenziswa kumlinganiselo wobude bekhebula, amalungu aphakathi, amalunga e-T, kunye nejoyinti yokuphelisa intambo.Le ndlela ingasetyenziselwa ukulungisa isantya samaza.
Indlela ye-Pulse yangoku: Ifanelekile ukulinganisa umgama wesiphoso esiphezulu sokumelana, impazamo yokuphuka.Ukusebenzisa i-coupler yangoku ukuqokelela imiqondiso evela kucingo lomhlaba, yenza umsebenzisi abe kude kumbane ophezulu.Le ndlela ikhuselekile kwaye ithembekile.
Ukubetha kwentliziyo kaninzi: indlela ehambele phambili yokulinganisa umgama.I-waveform kulula ukuyichonga kwaye ukuchaneka kuphezulu.
●200MHz iisampulu yexesha langempela.Max.Isisombululo somlinganiselo we-0.4m.Inommandla omncinci ofileyo kwaye ikhethekileyo kwintambo emfutshane kunye nekhebula elikufutshane.
●Chukumisa isikrini kwaye ucinezele ukusebenza kweqhosha
●Ikopi yePIP (umfanekiso.ugcino lwexeshana)
Kuya kubakho ifestile ephambili kunye neefestile ezintathu zokugcina okwethutyana zinokujonga iifom ezintathu zamaza kunye.
●Inkqubo yokusebenza eyakhelweyo
Ulawulo olukhethekileyo lwesoftware yokuphucula isoftware, i-backup kunye nokubuyisela.
●Umsebenzi wesikali
Indawo yokuqala, abafowunelwa abali-10, impazamo enye yentambo kunye nobude obunye obupheleleyo bunokusetwa.
Bonisa isikali kunye novavanyo lwamaza kunye
●Ukugcinwa kweWaveform kunye nonxibelelwano kunye nekhompyuter.
Ukugcinwa kwangaphakathi kweefom zamaza.
Nge-USB, ukukhuphela okanye ukulayisha idatha
Unxibelelwano ngekhompyuter
●Ulawulo lwamandla
Isibane sangasemva sibuthathaka ukuba akukho msebenzi kwi-2mins kunye nokucima amandla kwi-10mins ukuba akukho msebenzi.
Ibhetri eyakhelwe-ngaphakathi yePolymer Lithium-ion.
Ixesha lokusebenza lifikelela kwiiyure ezi-5 kusetyenziso ngalunye.
Ityala eliqinileyo, kulula ukuthwala.
| Iindlela zokukhangela | Indlela yempembelelo yombane ophantsi Indlela yangoku yempembelelo Indlela yempembelelo emininzi ukuba ihambelana ne-GD-4133S |
| Max.Isampulu frequency | 200MHz |
| Ukufumana uluhlu | 0-70dB |
| Umbane ophantsi we-impulse voltage | 30V |
| Max.isigqibo | 0.4m |
| Max.Indawo yoluhlu | 100km |
| Indawo efileyo | 2m |
| Ibhetri | Iibhetri zeNickel-metal hydride ezitshajwayo, ixesha lokunyamezela ngaphezulu kweeyure ezi-5 |
| Ujongano lonxibelelwano | i-USB |
| Ukunikezwa Amandla | Igalelo AC220V,50Hz,i-2A yangoku,intlawulo yeeyure ezisi-8 |
| Dim. | 274×218×81mm |
| Ubunzima | 3.5kgs |
| Ubushushu bokusebenza | -10℃-40℃ |
| Ukufuma | 5-90%RH |
| Ukuphakama | <4500m |

Isebenza kunye ne-GD-4133 Cable Fault Detector,isetyenziselwa ukufumanisa impazamo yokuvuza okuphezulu, impazamo ye-flashover,umhlaba ophantsi we-impedance kunye nempazamo yesekethe evulekileyo yeentambo zamandla.
I-GD-4133S ibonelele ngophawu lokudibanisa ipulse ye-GD-4133 kunyeyihlukanise kwizixhobo zamandla ombane aphezulu.
●Ukusebenzisa iteknoloji ephezulu kakhulu ye-pulse kunye ne-pulse balance.Ifom yamaza ebonakalisiweyo kulula ngakumbi ukuyichonga.
●Ngokhuseleko lwe-HV yokhuseleko, isekethe yokulinganisa kunye namandla ombane aphezulu we-impulse power ibekwe yodwa ngombane.
●Iingcingo ezilula, ezikhuselekileyo nezithembekileyo.
●Umbane wePulse: 300V(PP)
●Igalelo lamandla ombane wempembelelo: <35kV
●Igalelo elivumelekileyo lamandla empembelelo: <2000J
●Igalelo lamandla: 220V AC, 50Hz
●Ubungakanani: 560 * 230 * 220mm
●Ubunzima: 7kg.