Transformer Oyile Gas Chromatography Online Monitoring System
I-GDDJ-DGA Transformer Oil Gas Analyzer sisixhobo sokubeka iliso kwi-intanethi yegesi enyibilikileyo kwi-oyile ye-transformer esekelwe kwi-gas chromatography technology.Isiphoso esinokubakho sichongiwe, ukukhulula isilumkiso ngokwexabiso lokusetwa kwangaphambili ngenkqubo yokuxilongwa kweengcali.
Isixhobo samkela itekhnoloji yesampulu yolawulo olusasaziweyo kwaye sinokuzixilonga kunye nemisebenzi yokuzibuyisela.Imodyuli nganye yomsebenzi idityanisiwe ebuthathaka, isebenza ngokuzimeleyo, yamkele ubume be-rack, kulula ukugcinwa kobunjineli.
●Ukugcinwa kwamahhala, akukho mfuneko yokutshintsha isilinda segesi.
●Ukubona kwi-intanethi ukugxilwa kunye nesantya sokukhula kwe-H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Uyilo lwemodyuli kunye nesakhiwo esincinci, kulula ukugcinwa, kunye nokwandiswa okuphezulu, kunokuhlanganiswa ngokulula kwezinye izixhobo zokubeka iliso.
●Imowudi yesampulu yomjikelo wokucoca ubungakanani, ukubonisa imeko yerhasi enyityilisiweyo kwioyile ye-transformer.
●Itekhnoloji yokucoca i-vacuum engenampompo, akukho mfuneko yempompo yokucoca kunye nokuphucula ukuthembeka kunye nokuzinza kwenkqubo.
●Ikholamu ekhethekileyo yechromatographic eyinkimbinkimbi, ukuphucula iqondo lokuhlukana kokwakheka kwegesi.
●I-detector ekhethekileyo yomgca, idatha yokubeka iliso iyinyani kwaye ithembekile, iziphumo zovavanyo zisondele kakhulu kwidatha yebhubhoratri.
●Iyunithi ezimeleyo ngaphakathi kwe-chassis yokulawula ubushushu kunye nokufuma, ukususa impembelelo yengingqi kunye nexesha lonyaka.
●Ngokuchaneka okuphezulu kokufunyanwa kwedatha, yamkela △-ε amanani angama-24 i-ADC kunye nesihluzo sedijithali.Isebenzisa i-auto calibration ukuqokelela i-spectrogram.
●Ngeendlela ezahlukeneyo zokubonisa idatha kunye neendlela zokubuza, ingxelo kunye negrafu yentsingiselo.Idatha yembali inokugcinwa ukuya kuthi ga kwiminyaka eyi-10.
●Ukulungelelanisa okusingqongileyo okunamandla, isicelo esiyimpumelelo kubanda, ukushisa okuphezulu, umswakama ophezulu, indawo ephakamileyo.
●Ubuchule obunamandla bokuchasana nokuphazamiseka, ukuhambelana kwe-electromagnetic kunokwanelisa umgangatho ofanelekileyo.
●Ngamanqanaba amabini omsebenzi we-alamu, isignali ye-alamu inokudluliselwa kude.
●Umjikelo wokuhlalutya ngokukhawuleza, umjikelo omncinci wokubeka iliso yimizuzu engama-40, unokusekwa ngabasebenzisi.
●Gcwalisa iteknoloji yokubuyisela ioli, ngexesha lenkqubo ye-degassing, isampuli yeoli ayiqhagamshelani negesi ye-chromatogram ye-carrier carrier, ukusetyenziswa kweendlela ezahlukeneyo zokulawula, ukuqinisekisa ukuba i-return transformer body yesampuli yeoli ihlangabezana ngokupheleleyo neemfuno.
●Inkqubo yokuxilongwa kwenkqubo eyomeleziweyo, iziphumo zinikezelwa ngendlela ephuculweyo yokulinganisa ezintathu, indlela kanxantathu kaDavid kunye nendlela yomzobo wetyhubhu.
●Ngeendlela ezahlukeneyo zokunxibelelana ukudlulisa idatha, i-RS485, i-IEC61850, i-GPRS yokudluliselwa ngaphandle kwamacingo kunye nomyalezo omfutshane isetyenziselwa ukudlulisa idatha.
●Inkxaso ye-Ethernet / uxhumano lwe-optical, ukudluliselwa kwedatha, ulawulo lwesixhobo kunye nokusetha ipharamitha kunye nedijithali ngokupheleleyo kunye nokulawula kude.
●I-oyile / igesi auto calibration kunye nemisebenzi yokucoca i-auto ikhona.
| Ubushushu bendalo | -40℃~+ 70℃ | ||
| Ukufuma kokusingqongileyo | Ukufuma okuzalanayo 5-95%(akukho ukujiya) | ||
| Uxinzelelo lwe-Atmospheric | 80kPa-110kPa | ||
| Ukunikezwa Amandla | AC 220V±10%, 50Hz | ||
| Amacandelo okubeka iliso | H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, izinga lokukhula kunye nokugxila | ||
| Uhlalutyo kunye nomsebenzi wokuxilonga | Hlalutya kunye nokuxilongwa kwedatha yokubeka iliso ngeendlela ezintathu zokulinganisa, indlela yonxantathu kaDavid kunye nendlela ye-cube diagram.I-spectrogram yoqobo inokubonelelwa. | ||
| Min.Umjikelo wokufumanisa | I-40-60mins, ichazwe ngumsebenzisi, ingagqibekanga kane ngosuku. | ||
| Imowudi yesampulu | Isampulu yokukhwela ibhayisekile, ukubonisa imeko yexesha lokwenyani yerhasi yangaphakathi. | ||
| Indlela yokwahlula ioli kunye negesi | Vacuum degassing mode, degassing amaxesha amathathu ngokuqhubekayo. | ||
| Ubomi bogcino lwedatha | ≥ iminyaka eyi-10 | ||
| Ubuninzi berhasi yomthwali | Irhasi yemoto ezenzelayo, ayiphazanyiswa unyaka wonke.Akukho mfuneko yokutshintsha i-cylinder yegesi. | ||
| Irhasi yokubeka iliso | Uluhlu lokulinganisa | Min.ukubhaqwa | Impazamo |
| H2 | 2- 2000 ppm | 1 ppm | ±10% |
| CO | 5- 20000 ppm | 5 ppm | ±10% |
| CH4 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
| C2H4 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
| C2H6 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
| C2H2 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
| CO2 | 25- 20000 ppm | 25 ppm | ±10% |
| H2O | 1 - 800 ppm | ||
| Ubushushu beoyile | -40 ℃ ~ 200 ℃ | ||
| Ubungakanani bomoya bubonke | 0.2-15% | ||
| Iyonke i-hydrocarbon | 1 - 8000 ppm | ||
| Uzinzo (impazamo yomlinganiselo) | Kwimeko efanayo yokuvavanya, impazamo ayikho ngaphezu kwe-10% kwisampuli yeoli efanayo.(uxinzelelo oluphakathi) | ||
| IP iklasi | IP66 | ||
| Ukuphakama | ≤3000m |
| Ubushushu obugciniwe | -10℃~+45℃(ngaphakathi);-40℃~+70℃(ngaphandle) |
| Max.Umahluko wobushushu bemihla ngemihla | 25℃ |
| Max.Ubuntu bezizalwane | 95% (umyinge wemihla ngemihla);90% (umndilili wenyanga) |
| Uxinzelelo lomoya | 86kPa ~ 106kPa |
| Isakhono sokuchasa ukothuka | Ukukhawuleza okuthe tye 0.30g;ukukhawulezisa ngokuthe nkqo 0.15g |
| Indawo yofakelo | Ufakelo lwangaphakathi.Igumbi liya kuxhotyiswa nge-air-conditioner, akukho khuselo, ngaphandle kwemilinganiselo ye-anti-static. |
| Unikezelo lombane olulinganisiweyo (AC) | I-220V / 100V, impazamo evumelekileyo ± 20% (i-harmonics), i-total voltage disstortion rate ≤8%. |
| Unikezelo lombane olulinganisiweyo (DC) | I-220V / 110V, uluhlu oluvumelekileyo lokuguquguquka ± 20%. |
| Umlinganiselo wombane we-AC | I-57.7V / 100V / 220V, umthamo ogqithisiweyo ngu-1.2 amaxesha ombane olinganisiweyo, i-coefficient ephezulu ≥2. |
| Ikalwe ngoku AC | I-1A / 5A, umthamo womthwalo ogqithisiweyo ngamaxesha e-1.2 okulinganisa ngoku, ngokuqhubekayo ukusebenza, i-coefficient ephezulu ≥3. |
| Ilinganiswe rhoqo | 50Hz, imposiso evumelekileyo -5%~+5%. |
Ukunikezwa Amandla
Unikezelo lombane lwenkqubo yokubeka iliso kwimeko yesikhululo esingaphantsi kufuneka lukhuseleke kwaye luthembeke, kwaye izixhobo zolawulo lwesikhululo kufuneka zixhaswe yi-220VAC Unikezelo lombane olungaphazamisekiyo (UPS).Iyunithi nganye yokubeka iliso kwinkqubo yenkqubo inikwe amandla yi-220V AC system.
Ukukhuselwa kombane, ukumisa umhlaba, ukuchasana nokuphazamiseka
Inkqubo yokubeka iliso kwimeko yesikhululo esingaphantsi kuya kuba nemilinganiselo yokukhusela ngokuchasene nombane ogqithisileyo.
Akukho gridi yokumisa yahlukileyo yenkqubo yokubeka iliso kwimeko.Ngokomgaqo-siseko "wokumisa indawo enye", ucingo oluphantsi luxhunywe kwindawo enye yegridi engundoqo yokumisa i-substation.
Isixhobo sokukhusela i-voltage engaphezulu kuya kufakwa kumbane we-220V AC, umgca wonxibelelwano kunye nesiphelo esikhokelayo sothungelwano olusezantsi, kunye neeparamitha zesixhobo sokukhusela ziya kuhambelana nesalathisi sokusebenza sokufakelwa kwesixhobo.
I-chassis, ikhabhinethi kunye nomgangatho wokukhusela intambo yenkqubo yokubeka iliso kwimeko kufuneka isekelwe ngokuthembekileyo.Uxhulumaniso phakathi kweengqimba zenkqubo yenkqubo yokubeka iliso kwimeko, ukudibanisa phakathi koluhlu lwenkqubo kunye noluhlu lolawulo lwesitishi, kunye nokudibanisa phakathi kweechweba zonxibelelwano zezixhobo kuya kuba zodwa.
Isixhobo sifakwe kwigumbi ngaphandle kokhuselo lwe-electromagnetic.Isixhobo ngokwaso kufuneka sihlangabezane neemfuno zokuphazamiseka kwentsimi ye-anti-electromagnetic kunye nefuthe le-electrostatic.Kwimeko yombane ogqithise umbane, ukusebenza ngokugqithisileyo kunye nempazamo yesekethe emfutshane yesixhobo sokuqala, isixhobo asiyi kungasebenzi kakuhle, kwaye zonke izixhobo ziya kuhlangabezana nezi mfuno zokuchasana nokuphazamiseka:
I-1) Ukukhutshwa kwe-electrostatic, ihambelana ne-GB / T 17626-4-2 iklasi yesi-4.
2) Kwintsimi ye-radiation electromagnetic, ihambelana ne-GB/T 17626-4-3 iklasi 3.
3) Ukuhamba ngokukhawuleza, kuhambelana ne-GB / T 17626-4-4 iklasi yesi-4.
4) Ngokutya, ihambelana ne-GB/T 17626-4-5 iklasi 3.
5) Ukuqhuba i-electromagnetic induction, ihambelana ne-GB/T 17626-4-6 iklasi 3.
6) Kwintsimi ye-electromagnetic frequency frequency, ihambelana ne-GB/T 17626-4-8 iklasi yesi-4.
7) Kwintsimi ye-pulse electromagnetic, ihambelana ne-GB/T 17626-4-9 iklasi yesi-5.
8) Kwintsimi yemagnethi emanzi, ihambelana ne-GB/T 17626-4-10 iklasi yesi-5.
9) Ngamaza oscillating, ihambelana ne-GB / T 17626-4-12 iklasi ye-2 (i-signal port).
| Hayi. | Igama leSixhobo | Iinkcukacha | Qty | Phawula |
| 1 | Transformer Oil Gas Online esweni inkqubo | 535*600*1100 | 1 | |
| 2 | Flange | Ngokusekelwe kwizibuko le-transformer | 2 | |
| 3 | ityhubhu yensimbi engenasici | Φ6*30M | 1 | |
| 4 | Ifayibha yamehlo | Multimode 4-core, 200M | 1 | |
| 5 | Ibhokisi yetheminali | 2 | ||
| 6 | Umtsi | SC-SC | 2 | |
| 7 | Isiguquli seFayibha | iindlela ezininzi | 1 | |
| 8 | Intambo ye-Ethernet | 0.5M | 2 | |
| 9 | Screw | M12*1.25M, Φ6 | 2 | |
| 10 | Ukwandiswa screw | M10*100 | 4 | |
| 11 | Isitshixo seKhabhinethi | 2pcs | 1 | |
| 12 | Ikhadi lentambo | 4pcs + amaqhina amaninzi entambo enayiloni | 1 | |
| 13 | ityhubhu yensimbi engenasici | Φ3*2M | 1 | |
| 14 | Umbhobho we-Insulation kunye namanye amacandelo | Umbhobho we-Insulation Φ6 * 2M 4pcs, Au tape 50 * 25M 1roll, intsimbi yensimbi engenasici 8 * 32 2pcs | 1 |