I-GDC-9560B yeNkqubo yaMandla ye-Insulation Oil Gas Chromatograph Analyzer
I-GDC-9560B I-Gas Chromatograph Analyzer kukuhlalutya umxholo wegesi we-oyile yokugquma ngendlela yegesi yechromatographic.Kuyasebenza ukugweba ukuba ngaba izixhobo ezisebenzayo zineempazamo ezinokubakho njengokushisa okuphezulu, ukukhutshwa okanye ukungabikho, ukuqinisekisa ukhuseleko lwegridi yamandla.Kukwayimfuneko ukuba isetyenziselwe umenzi wezixhobo zegesi/zeoyile ukuhlola izixhobo zabo phambi kokuba umke kumzi-mveliso.
Itekhnoloji yohlalutyo lwe-chromatography yegesi yindlela yokwahlula kunye nohlalutyo lwemixube yamacandelo amaninzi.Ngokukodwa isebenzisa ukuhlukana kwendawo yokubilisa, i-polarity kunye ne-adsorption coefficient yecandelo ngalinye kwisampuli kwikholamu, ukwenzela ukuba amacandelo ahlulwe kwikholamu, kwaye amacandelo ahlukeneyo ahlalutye ngokomgangatho kunye nobungakanani.
I-chromatograph yegesi isebenzisa igesi njengesigaba esihambayo (i-carrier gas).Xa isampuli ithunyelwa kwi-injector kunye ne-vaporized, ithathwa yi-carrier carrier kwikholomu epakishweyo okanye ikholamu ye-capillary ngenxa yendawo yokubilisa, i-polarity kunye ne-adsorption coefficient yecandelo ngalinye kwisampuli.Umahluko kukuba amacandelo ahlukaniswe kwikholomu, kwaye ke ii-detectors ezixhunywe kwikholamu zifunyenwe ngokulandelelana ngokweempawu ze-physicochemical zamacandelo, kwaye ekugqibeleni izibonakaliso zombane eziguqulwayo zithunyelwa kwi-workstation ye-chromatographic.I-chromatogram yegesi yecandelo ngalinye irekhodwa kwaye ihlalutywe yi-chromatographic workstation ukufumana iziphumo zohlalutyo lwecandelo ngalinye.
●Yamkela i-10/100M ephuculweyo yonxibelelwano lwe-Ethernet ujongano kunye ne-IP eyakhelwe-ngaphakathi istaki seprotocol, esenza ukuba isixhobo siqonde ngokulula ukuhanjiswa kwedatha kumgama omde nge-LAN yangaphakathi kunye ne-Intanethi.Iququzelela ukusekwa kwebhubhoratri kwaye yenza lula ilabhoratri.Ulungelelwaniso luququzelela ulawulo lwedatha yokuhlalutya.
●Uyilo lweenkqubo ezi-3 zoqhagamshelwano ezizimeleyo.Inokudityaniswa nokucwangciswa kwendawo (i-laboratory), ilula ngakumbi kubaphathi ukuba babeke iliso kwindlela yokusebenza kunye nokuhlalutya iziphumo.
●Indawo yokusebenzela ye-NetChrom TM enokuzikhethela ingaxhasa ngaxeshanye iichromatographs ezininzi zokusetyenzwa nokulawulwa kwedatha, ukwenza lula ulawulo lwamaxwebhu kunye nokunciphisa utyalo-mali lwelebhu yomsebenzisi kunye neendleko zokusebenza.
●Inkqubo ngesiNgesi kunye nesiTshayina, enokutshintshwa ngokukhululekileyo.
●Indawo yokulawula ubushushu inokubizwa ngokukhululekileyo ngumsebenzisi, olungele abasebenzisi.
●Ukusebenzisa imowudi yokusebenza ye-multiprocessor parallel, izinzile kwaye inokuthenjwa.Idibana nohlalutyo olunzima lwesampulu.Ixhotyiswe ngeentlobo ngeentlobo zezixhobo zokusebenza eziphezulu ezifana ne-FID, i-TCD, i-ECD, kunye ne-FPD.Ukuya kuthi ga kwiimvavanyo ezine ezinokufakwa ngexesha elinye.Kwakhona kunokwenzeka ukusebenzisa indlela yokongeza i-detector, ekulungele ukuthenga nokufaka ezinye ii-detectors emva kokuba isixhobo sithengiwe.
●Isixhobo samkela ubume bemodyuli, eyilwe kwaye yatshintshwa, kulula ukuyiphucula nokukhusela ukusebenza kakuhle kotyalo-mali.
●Inkqubo entsha yokulawula ukushisa kwe-microcomputer inokuchaneka kokulawula ubushushu obuphezulu kunye nokuthembeka okuphezulu kunye nokusebenza okuchasene nokuphazamiseka.Ineenkqubo ezintandathu ezizimeleyo zokulawula ubushushu, ezinokuqonda inkqubo yobushushu obunamanyathelo ali-16, eyenza ukuba izixhobo zibe nako ukuhlalutya isampulu.Inenkqubo yokuvula umnyango wangemva ngokuzenzekelayo kwi-oven, ephucula ukuchaneka kokulawula ukushisa okuphantsi kunye nokwandisa isantya sokunyuka / ukuhla.
●Isixhobo sinokuxhotyiswa nge-electronic flow controller (EFC) kunye nomlawuli woxinzelelo lwe-elektroniki (EPC) ukuqonda ulawulo lwedijithali, olunokuphucula kakhulu ukuveliswa kweziphumo ezisemgangathweni kunye nobuninzi.
●Inkqubo yoyilo lwesixhobo sokuziqalisa inokugqibezela ngokulula uhlalutyo lwe-intanethi lweesampulu zegesi (ifuna iinxalenye ze-intanethi ezizenzekelayo zokutofa).
●Inkqubo yokusebenza yekhibhodi yokulawula i-microcomputer ilula kwaye ikulungele ukusebenza;kunye neteknoloji yokuchonga ngokuzenzekelayo ye-detector iyilwe.Ngokuxilongwa kwesiphoso kunye nokukhuselwa kwedatha yokucima amandla, iiparamitha zinokuthi zikhunjulwe ngokuzenzekelayo.
●Isixhobo sakhelwe ingxolo ephantsi, isisombululo esiphezulu se-24-bit AD sesekethe kunye nokugcinwa kwesiseko kunye nokususa okusisiseko.
●Ukuqokelela izibonakaliso zechromatographic kunye nokusebenza kwedatha, efanelekileyo kwiWinXP, Win2000, Windows7 kunye nezinye iinkqubo zokusebenza.Idatha yesampula ifundwa kwiifayile ze-CDF ezihlangabezana nemigangatho ye-A / A (American Analytical Society), ngoko inokusetyenziswa kunye ne-Agilent, Amanzi kunye nezinye iindawo zokusebenza ze-chromatography.
●Inkqubo yeChromatographic enamalungelo azimeleyo ngokupheleleyo epropathi enomgangatho ophezulu wokuqonda, enojongano olusemgangathweni lwe MODBUS/TCP, inokufakwa ngokulula ngeDCS.
●Isixhobo sinokudityaniswa ne-auto sampler eveliswe ngabavelisi abaninzi basekhaya nabangaphandle;njenge-Shimadzu AOC-20i, i-HT yenkampani ye-HT ye-HT ye-high-efficiency liquid, i-gas auto sampler.
Iigesi zokubona | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 iigesi),O2(ukhetho), N2 (ukhetho) |
Display | 192*64 dot matrix LCD |
Indawo yokulawula ubushushu | 6 iindlela |
Uluhlu lokulawula ubushushu | ubushushu begumbi +5℃~400℃, unyuso 1℃, ukuchaneka:±0.1℃ |
Umyalelo wokucwangcisa | 16 amanyathelo |
Ireyithi yokunyuka kweNkqubo | 0.1~40℃/min |
Ulawulo lwegesi | Imowudi yokulawula ivalve ngoomatshini, imowudi yolawulo lokuhamba koxinzelelo lwe-elektroniki ngokuzikhethela |
Iziganeko zangaphandle | 4 amajelo |
Uhlobo lwesitofu | ikholamu epakishweyo, i-capillary, inaliti ye-valve yeendlela ezintandathu, inaliti ye-automatic headspace, njl. |
Inani lee-detectors | iipcs ezi-4;FID, TCD, ECD, FPD (uyazikhethela) |
Qalisa inaliti | manual, oluzenzekelayo ozikhethelayo |
Ujongano lonxibelelwano | I-Ethernet: IEEE802.3 |
IiNkcazelo zeDetector | |
Isikhangeli se-ionization yomlilo weHydrogen (FID) | |
Umda wokufunyanwa | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Ingxolo esisiseko | ≤ 5 × 10-14A |
Baseline drift | ≤ 1 × 10-13A / 30min |
Uluhlu lomgca | ≥106 |
Isikhangeli se-Thermal Conductivity (TCD) | |
Uvakalelo | S≥2500mV•ml/mg (benzene/toluene) (yandisiwe 1, 2, 4, 8 amaxesha ngokuzithandela) |
Ingxolo esisiseko | ≤20μV |
Baseline drift | ≤30μV/30min |
Uluhlu lomgca | ≥104 |
Isibonisi sokubanjwa kombane (ECD) ngokuzikhethela | |
Umda wokufunyanwa | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
Ingxolo esisiseko | ≤0.03mV |
Baseline drift | ≤0.2mV/30min |
Uluhlu lomgca | 103 |
Umthombo we-radioactive | 63Ni |
Isitshingi seFtometriki yomlilo (FPD) ngokuzikhethela | |
Umda wokufunyanwa | (S) ≤ 5×10-11g / s, (P) ≤ 1×10-12g/s;methyl parathion/ ethanol ngokupheleleyo) |
Ingxolo esisiseko | ≤ 3 × 10-13A |
Baseline drift | ≤ 2 × 10-12A / 30min |
Uluhlu lomgca | Fokanye isulfure ≥ 102, ye-phosphorus ≥ 103 |
IYunithi ePhambili yeChromatograph yegesi | Iseti e-1 |
Ijenereyitha yeHydrojeni | Iseti e-1 |
Ijenereyitha yomoya | Iseti e-1 |
IShaker enemisebenzi emininzi | Iseti e-1 |
I-Valve yokunciphisa uxinzelelo olusemgangathweni | Iseti e-1 |
I-Nitrogen yokuNciphisa iValve | Iseti e-1 |
I-Nitrogen Cylinder | 1 ibhotile |
Igesi eqhelekileyo | 1 ibhotile |
Indlela yegesi nut M8X1Φ3.2 | 10 iipcs |
Uxinzelelo lwevalve edibeneyo yokunciphisa uxinzelelo | iipcs ezi-5 |
Capillary column nut Φ0.8 | iipcs ezi-4 |
Ikholamu nati Φ4.2 kunye Φ3.2 | Nganye iipcs ezi-5 |
Umbhobho wangaphakathi wegesi yentsimbi Φ2 | 10 iipcs |
Indlela yegesi yokutywina iphedi | 50 iipcs |
Capillary sampler evaporative pad | 50 iipcs |
Iphedi yegraphiti yeCapillary Φ0.8 | 20 iipcs |
Iphedi yegraphiti Φ4.2 kunye ne Φ3.2 | Nganye iipcs ezili-10 |
Fuse | iipcs ezi-4 |
Screw M3X5 | iipcs ezi-6 |
Umbhobho werhasi we-PE Φ3 | 20m |
I-1ml yesitofu seplastiki | iipcs ezi-5 |
Isitofu se-100ml | iipcs ezi-5 |
Inaliti | 10 iipcs |
I-20ml yesitofu seglasi | iipcs ezi-5 |
5ml isitofu seglasi | iipcs ezi-5 |
1ml isitofu seglasi | iipcs ezi-5 |
Ikliphu yobungakanani | iipcs ezi-2 |
Vaseline 30g | iipcs ezi-2 |
Slotted screwdriver 50mm 70mm | Nganye i-1 pc |
Crosshead screwdriver 50mm 70mm | Nganye i-1 pc |
Isitshixo 8-10 | 1 pc |
Isitshixo 12-14 | 2 pc |
Iimpumlo ezibukhali | 1 pc |
Intambo ephantsi | 1 pc |
Intambo yomqondiso | 1 pc |
Ikhodi yamandla | 1 pc |
Umnqwazi werabha | 20 pc |
Isikhwama se-aluminium foil | iipcs ezi-2 |
Inaliti ephindwe kabini | 25 iipcs |
Idiski | 1 pc |
Intambo yonxibelelwano | 1 pc |
Ibhloko yegesi | 1 pc |