GD3127 Series High Voltage Insulation Resistance Tester
I-GD3127 Series Insulation Resistance Tester isetyenziswa ngokubanzi ekugcinweni kwezixhobo zombane kwi-transformer substation, iplanti yamandla, njl.
-
I-GD-875/877 Ikhamera ye-Infrared ye-Thermal
Ikhamera ye-infrared ye-GD-875/877 isebenzisa i-25μm 160*120 detector, uluhlu lomlinganiselo wobushushu -20℃–+ 350℃,3.5inch TFT LCD screen.
Isicelo
Ulondolozo lothintelo
- Umzi-mveliso wamandla: Intambo yamandla kunye nesixhobo sombane sokujonga imeko ye-thermal;ukuxilongwa kwesiphene kunye nesiphene.
- Isixokelelwano soMbane: Chonga kwangaphambili phambi kokuba kwenzeke ukugcwala kwesekethe
- Inkqubo yoomatshini: Nciphisa ixesha lokuphumla kwaye uthintele ukusilela okuyintlekele.
Isayensi yokwakha
- Uphahla: Ukuchongwa ngokukhawuleza kweengxaki zokungena kwamanzi.
- Ubume: Uphicotho lwamandla orhwebo kunye nendawo yokuhlala.
- Ukubona ukufuma: Khangela unobangela wokufuma kunye nokungunda.
- Uvavanyo:Vavanya amanyathelo okulungisa ukuqinisekisa ukuba indawo yomile ngokupheleleyo.
-
GDHX-9500 Phase Detector
I-GDHX-9500 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba kunye nesigaba sokulandelelana kolandelelwano kwi-substation, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa ukulandelelana kwesigaba.
-
GDHX-9700 Phase Detector
I-GDHX-9700 Phase Detector isetyenziswa kakhulu kwiintambo zamandla ombane, isigaba, kunye nesigaba sokulandelelana kolandelelwano kwisitishi esingaphantsi, kunye nemisebenzi ephambili ebandakanya ukuhlolwa kombane, ukulinganisa kwesigaba kunye nokulinganisa kokulandelelana kwesigaba.
-
GD2000D Insulation Resistance Tester
I-GD2000D i-digital insulation resistance tester eveliswe yinkampani yethu isebenzisa inkqubo esebenza ngexesha lokwenyani leshiphu enye.Isalathisi se-analog yedijithali kunye nesiboniso sekhowudi yentsimi yedijithali zidibaniswe ngokugqibeleleyo.
-
I-GDWR-5A i-Earth Resistance Tester yeGround Grid
I-GDWR-5A i-Earth Resistance Tester sisixhobo sovavanyo oluchanekileyo oluphezulu olusetyenziswa kwiinkalo ezahlukeneyo ezifana nezitishi zokuvavanya ukumelana nomgangatho kunye neeparitha ezinxulumene nazo.Isixhobo sineempawu zomthamo omncinci, ubunzima obulula, ukuthwala okufanelekileyo, ukusebenza okunamandla okuchasana nokuphazamiseka kunye nokuchaneka okuphezulu.
-
GDDJ-HVC Dielectric Loss Tester for Live Capacitive Equipment
Ngokuqhelekileyo kukho iindlela ezimbini zokubeka iliso kwimeko yokufakelwa kwezixhobo zombane eziphezulu kwizikhululo ezincinci: ukubeka iliso kwi-intanethi kunye nokuphila (okuphathekayo) kwi-intanethi.
-
GDDJ-HVC Substation Substation Monitoring System
Ngokuqhelekileyo kukho iindlela ezimbini zokubeka iliso kwimeko yokufakelwa kwezixhobo zombane eziphezulu kwizikhululo ezincinci: ukubeka iliso kwi-intanethi kunye nokuphila (okuphathekayo) kwi-intanethi.