I-GDW-102 ye-Oli ye-Dew Point Tester (I-Coulometric Karl Fischer Titrator)
Itekhnoloji ye-Coulometric Karl Fischer isetyenziselwa ukulinganisa ngokuchanekileyo ukufuma kwesampulu elinganisiweyo.Ithekhinoloji isetyenziselwa ukuchaneka kunye neendleko zovavanyo ezitshiphu.Imodeli ye-GDW-102 yokulinganisa ngokuchanekileyo ilandelelanisa ukufuma kwiisampuli zolwelo, eziqinileyo kunye negesi ngokobuchwephesha.Isetyenziselwa umbane, i-petroleum, iikhemikhali, ukutya njalo njalo.
●Sebenzisa ukuphuculwa kwesekethe ye-PWM ye-electrolysis ukunciphisa ukuchithwa kwamandla kwesixhobo.
●Umgangatho ophezulu wokulinganisa umqondiso we-electrode kunye nokufunyanwa kwesekethe yenza isigqibo sokuphela kwe-electrolytic ngokukhawuleza kwaye ngokuchanekileyo ngekhono elinamandla lokuchasana nokuphazamiseka.
●Sebenzisa iindlela zembuyekezo ye-electrolyte engenanto yangoku kunye nembuyekezo ye-electrolyte drift yokulinganisa ukuyila iziphumo zovavanyo.
●Yakhelwe kwifomula yokubala emithathu ukuvelisa ingxelo ngokuzenzekelayo.
●Amaqhosha alawula isantya sokuxuba anezantya ezilishumi(0~9speed).
●Ukulinganisa i-electrode open-circuit fault and short circuit fault ngokuzenzekelayo.
●Inokugcina iirekhodi zembali ezingama-256 kunye nexesha.
●Iwotshi yekhalenda enobushushu inokugcina ngokuzenzekela umhla kunye nexesha lovavanyo ngokuchanekileyo, enokusebenza iminyaka eli-10 ngaphezulu umbane uphantsi.
●Xa isixhobo singasebenzi ixesha elide, isikrini seLCD siya kuvala ngokuzenzekelayo ukukhusela isikrini kwaye sigcine ubomi besikrini.Cinezela nawaphi na amaqhosha ukuyeka ukhuseleko lwesikrini.
●Kukho ujongano lweRS232 lokunxibelelana nePC kunye nomshicileli omncinci ngokulula.
| Electrolysis yangoku | Ubuninzi.400mA |
| Ubuninzi be-electrolysisisantya | Ubuninzi.2.4mg/min |
| Uluhlu lokulinganisa | 10ug~100mg |
| Uvakalelo | 0.1ug |
| Ukuchaneka | ±3ug ye-10ug~1mg I-RSD 0.3% okanye ngaphantsi kwe-1mg okanye ngaphezulu |
| Ubushushu obugciniwe | 5~35℃ |
| Ukufuma kwendawo | ≤85% RH |
| Ukunikezwa Amandla | AC220V±20% 50HZ±10% ,40VA |
| Imilinganiselo | 270×210×125(mm) |
| Ubunzima | 5kg |
| Ubuninzi bokusetyenziswa kwamandla | 30W |
| Iyunithi ephambili | Iqhekeza eli-1 |
| Electrolysis electrode | Iqhekeza eli-1 |
| I-electrode yokulinganisa | Iqhekeza eli-1 |
| Ukuvuselela i-nut | iipcs ezi-2 |
| I-silica gel particle | Iqhekeza eli-1 |
| I-silica gel mat | 10 iipcs |
| 0.5μl Isampulu yesitofu | Iqhekeza eli-1 |
| 50μl Isampulu yesitofu | Iqhekeza eli-1 |
| 1ml Isampuli yesitofu | Iqhekeza eli-1 |
| Umbhobho wokomisa | Iqhekeza eli-1 |
| Ikhodi yamandla | Iqhekeza eli-1 |
| Vacuum igrisi | Iqhekeza eli-1 |
| Electrolyte | Iqhekeza eli-1 |
| Isikhokelo somsebenzisi | Ikopi enye |
| Ingxelo yovavanyo lwasefektri | Ikopi enye |