GDOH-II Insulating Oil Gas Content Tester
I-GDOH-II i-Insulating Oil Content Tester ngumvavanyi wesizukulwana esitsha wamkela inzwa yokuchaneka ephezulu evela kumazwe angaphandle kunye ne-teknoloji entsha ye-sensor.Isekelwe kumgangatho we-DL423-91 woshishino lwamandla kunye nemigangatho yelizwe efanelekileyo.Isebenza ngakumbi, izinzile kwaye inokwethenjelwa ekusebenzeni, kulula ukuyisebenzisa kwaye ifaneleke ngakumbi ukumiselwa komxholo werhasi kwisixhobo esigcwele i-oyile ephezulu.Sisixhobo esifanelekileyo sovavanyo kwilabhoratri.
●Isakhiwo sesinyithi yonke into sigwema iingxaki ze-fragility kunye nokutywinwa okungahambi kakuhle kwe-glassware tester.
●Ukusetyenziswa kokuchaneka okuphezulu kunye nozinzo oluphezulu olungeniswa ngaphandle kwe-sensor yoxinzelelo oluhlukeneyo kwenza idatha yovavanyo ichaneke ngakumbi kwaye iphindwe.
●Umjikelo wovavanyo uqulethe abenzi boluvo abalinganisa uxinzelelo lwe-atmospheric kunye nobushushu be-ambient.Nokuba uphi na, unokulinganisa ngokuzenzekelayo ubushushu be-ambient kunye noxinzelelo lwe-atmospheric kwindawo okuyo, uguqule ngokuzenzekelayo kumxholo werhasi ku-0 ° phantsi koxinzelelo oluqhelekileyo lomoya, kwaye uyibonise ngqo kwisikrini se-LCD.
●Inkqubo yovavanyo olulodwa lwe-gas injection anti-standard test ikuvumela ukuba ukhangele ngokulula ukuba isixhobo silinganiswe okanye silinganiswe ngokuchanekileyo.
●Ixesha lokuvavanya isampuli yeoli lifutshane, kwaye lonke ixesha lokuvavanya lithatha kuphela malunga nemizuzu ye-7.
●Ngethuba lovavanyo, ukusebenza kwempompo ye-vacuum kulawulwa sisixhobo ngokwesimo, esinciphisa kakhulu ingxolo kwaye sandise ubomi benkonzo yempompo yokucoca.
●Isixhobo sinokugcina ngokuzenzekelayo idatha yeshumi elinesibini lokugqibela, kwaye sigcine ixesha lokuvavanya, ubushushu, uxinzelelo lwe-atmospheric, njl., ukuze ukwazi ukujonga ngokulula idatha.
●Ngomsebenzi woshicilelo, ungaprinta idatha yovavanyo ngokweemfuno zakho.
●Isampuli yeoli efanayo inokukhethwa kwinani leemvavanyo.Emva kokuba uvavanyo lugqityiwe, iziphumo zodwa kunye ne-avareji ziya kuboniswa kumboniso okanye ziprintwe.
| Inzwa yoxinzelelo oluphezulu oluchanekileyo lwe-elektroniki | Isisombululo asikho ngaphantsi kwe-0.1%. | |
| Ubuncinci bomda wokubona | Akukho ngaphezu kwe-0.2%. | |
| Ukuchaneka | Impazamo enxulumene neziphumo zomlinganiselo ophindaphindiweyo akufunekanga idlule kula maxabiso alandelayo: | |
| Umxholo werhasi kwi-oyile (iqhezu lomthamo), % | Impazamo ehambelanayo,% | |
| < 0.5 | 10 | |
| 0.5~1.0 | 8 | |
| 1.0~3.0 | 5 | |
| >3.0 | 3 | |
| Degassing igumbi lolawulo lobushushu uluhlu | 5℃ ukuya 70℃ ngaphezu kobushushu begumbi | |
| Ukusebenza kombane | AC 220V±10%, 50Hz | |
| Ubungakanani | 450*325*350 mm | |
| Ubunzima | Malunga ne-20kg | |
| Umvavanyi | Iseti e-1 |
| Ikhodi yamandla | Iqhekeza eli-1 |
| Impompo yokufunxa kunye nesinxibelelanisi | Iseti e-1 |
| Umbhobho wentsimbi ye-3mm | 1.5m, 0.5m |
| Isidibanisi sesirinji | Iseti e-1 |
| Fuse 10A | Iziqwenga ezi-3 |
| M8×1 nut | Iziqwenga ezili-10 |
| Itywina | Iziqwenga ezili-10 |
| Isibiyeli sesirinji | Iqhekeza eli-1 |
| Isirinji yokulinganisa i-1mL | Iqhekeza eli-1 |
| Impompo yokucoca iRotary vane vacuum | Iseti e-1 |
| Incwadi Yemiyalelo | Ikopi enye |
| Isiqinisekiso seMveliso | Ikopi enye |
| Ingxelo yovavanyo lwasefektri | Ikopi enye |
| Uluhlu lokupakisha | Ikopi enye |