GDJW-40B Wireless Insulator Tester
I-GDJW-40B ingasetyenziselwa ukuvavanya i-voltage yokusasazwa kwe-insulator exhonyiweyo ehlawulisiweyo okanye ukubonwa kwebhubhoratri yesithinteli esinqunyanyisiweyo, kunye nokwenza ukuba kubonwe ngokufanelekileyo ingxaki yangaphakathi efihliweyo ye-insulator, ukuphucula ukuthembeka kokusebenza kwenkqubo yegridi yamandla, kunye nokuphucula. ukusebenza kakuhle kwabasebenzi abaqhuba uvavanyo ephilayo.Le mveliso ithatha i-wireless transmission, umgama wonxibelelwano phakathi kwe-detector kunye ne-terminal ebanjwe ngesandla ingafikelela kwi-100m ngaphezulu, Yenza inkqubo yokulinganisa ikhuseleke ngokwenene kwaye ithembekile, ikhawuleza kwaye ichanekile.Ukongeza, isixhobo sinomsebenzi onamandla kakhulu wokuchasana nokuphazamiseka, ukuthobela ngokupheleleyo (i-EMC) iimfuno ezisemgangathweni, ukulungelelanisa imeko yokuphazamiseka kwentsimi ye-electromagnetic.
●Umbane osebenzayo: 35-1000KV, amanqanaba ombane ahlukeneyo ayasebenza.
●Uluhlu lokulinganisa i-Voltage: 0-40kV (i-voltage ekhethekileyo inokwenziwa ngokwezifiso).
●Impazamo yomlinganiselo: ≤±1%.
●Umlinganiselo wesampulu: amaxesha ali-10/S.
●Izicwangciso zexesha lomhla: lungisa umhla kunye nexesha, ukuququzelela abasebenzisi ukukhangela, ukujonga idatha yembali.
●Iisetingi zexesha lokukhanya ngasemva: kukhanya rhoqo, kucinywe rhoqo, imizuzu eyi-0-999 inokusekwa.
●Ukucinywa kwamandla okuzenzekelayo kuseto: soze, imizuzu eyi-0-999 inokusetwa.
●Umgama wothumelo lwe-terminal ebanjwe ngesandla kunye ne-detector yi-≤100m.
●Uyilo lweemowudi ezininzi, ukusetyenziswa okunamandla, ukhuseleko ngakumbi kwaye lulungele.
●Uyilo oludibeneyo lwendalo yonke, luvumela ukulungelelanisa ngokuguquguqukayo indlela yokulinganisa ngokwendawo yokunqunyanyiswa komtya we-insulator.
●Ikhuselwe kabini, isakhono esinamandla sokuchasa ukuphazamiseka, sithobela ngokupheleleyo imigangatho ye-EMC.
●Ujongano olulodwa lomatshini womntu, kulula ukuwusebenzisa.
| Uluhlu lokulinganisa umbane | 0-40kV (amandla ombane akhethekileyo anokwenziwa ngokwezifiso) |
| Imposiso yokulinganisa | ±1% |
| Isigqibo | 0.01kV |
| Ireyithi yesampulu | 10amaxesha/S |
| Ukusebenza ngoku | ≤120mA(Itheminali ebanjwa ngesandla),≤40mA(Isikhangeli) |
| Ukunikezwa Amandla | 2*1.5VAA ibhetri eyomileyo (itheminali ebanjwa ngesandla) 2*1.5VAAA ibhetri eyomileyo (Isikhangeli) |
| Ixesha elizinzileyo lokusebenza | ≥12h |
| Umgama wothumelo | ≥100m (umbane owaneleyo) |
| Bonisa | Umboniso we-LCD, unokuboniswa ngokucacileyo phantsi kokukhanya kwelanga. |
| Ubushushu bokusebenza | -35℃---+60℃ |
| Ubushushu bokugcina | -40℃---+65℃ |
| Ubuntu bezizalwane | ≤90%RH Ayina-condensate |
| Hayi. | Ubumbeko olusisiseko | Iyunithi | Qty. | Phawula |
| 1 | Itheminali ebanjwa ngesandla | iseti | 1 | |
| 2 | Umtshina ozinikeleyo | iqhekeza | 1 | |
| 3 | A,B Umtshini | ingcambu | 2 | |
| 4 | AA Ibhetri eyomileyo (1.5V) | icandelo | 2 | |
| 7 | AAA Ibhetri eyomileyo (1.5V) | icandelo | 2 | |
| 8 | Ngenisa ingxowa ephathekayo | iqhekeza | 1 | |
| 9 | 220kV Intonga ye-insulation | ingcambu | 1 | ≤220kV ihambelana ne4amacandelo4Intonga ye-M insulation,≥330kV dibanisa ne6 amacandelo6Intonga ye-M insulation |
| 10 | Incwadana yokusebenza | ikopi | 1 | |
| 11 | Ingxelo yovavanyo | ikopi | 1 | |
| 12 | Ikhadi lewaranti | ikopi | 1 | |
| 13 | Uluhlu lokupakisha | ikopi | 1 |