GDJW-40B Wireless Insulator Tester
I-GDJW-40B ingasetyenziselwa ukuvavanya i-voltage yokusasazwa kwe-insulator exhonyiweyo ehlawulisiweyo okanye ukubonwa kwebhubhoratri yesithinteli esinqunyanyisiweyo, kunye nokwenza ukuba kubonwe ngokufanelekileyo ingxaki yangaphakathi efihliweyo ye-insulator, ukuphucula ukuthembeka kokusebenza kwenkqubo yegridi yamandla, kunye nokuphucula. ukusebenza kakuhle kwabasebenzi abaqhuba uvavanyo ephilayo.Le mveliso ithatha i-wireless transmission, umgama wonxibelelwano phakathi kwe-detector kunye ne-terminal ebanjwe ngesandla ingafikelela kwi-100m ngaphezulu, Yenza inkqubo yokulinganisa ikhuseleke ngokwenene kwaye ithembekile, ikhawuleza kwaye ichanekile.Ukongeza, isixhobo sinomsebenzi onamandla kakhulu wokuchasana nokuphazamiseka, ukuthobela ngokupheleleyo (i-EMC) iimfuno ezisemgangathweni, ukulungelelanisa imeko yokuphazamiseka kwentsimi ye-electromagnetic.
●Umbane osebenzayo: 35-1000KV, amanqanaba ombane ahlukeneyo ayasebenza.
●Uluhlu lokulinganisa i-Voltage: 0-40kV (i-voltage ekhethekileyo inokwenziwa ngokwezifiso).
●Impazamo yomlinganiselo: ≤±1%.
●Umlinganiselo wesampulu: amaxesha ali-10/S.
●Izicwangciso zexesha lomhla: lungisa umhla kunye nexesha, ukuququzelela abasebenzisi ukukhangela, ukujonga idatha yembali.
●Iisetingi zexesha lokukhanya ngasemva: kukhanya rhoqo, kucinywe rhoqo, imizuzu eyi-0-999 inokusekwa.
●Ukucinywa kwamandla okuzenzekelayo kuseto: soze, imizuzu eyi-0-999 inokusetwa.
●Umgama wothumelo lwe-terminal ebanjwe ngesandla kunye ne-detector yi-≤100m.
●Uyilo lweemowudi ezininzi, ukusetyenziswa okunamandla, ukhuseleko ngakumbi kwaye lulungele.
●Uyilo oludibeneyo lwendalo yonke, luvumela ukulungelelanisa ngokuguquguqukayo indlela yokulinganisa ngokwendawo yokunqunyanyiswa komtya we-insulator.
●Ikhuselwe kabini, isakhono esinamandla sokuchasa ukuphazamiseka, sithobela ngokupheleleyo imigangatho ye-EMC.
●Ujongano olulodwa lomatshini womntu, kulula ukuwusebenzisa.
Uluhlu lokulinganisa umbane | 0-40kV (amandla ombane akhethekileyo anokwenziwa ngokwezifiso) |
Imposiso yokulinganisa | ±1% |
Isigqibo | 0.01kV |
Ireyithi yesampulu | 10amaxesha/S |
Ukusebenza ngoku | ≤120mA(Itheminali ebanjwa ngesandla),≤40mA(Isikhangeli) |
Ukunikezwa Amandla | 2*1.5VAA ibhetri eyomileyo (itheminali ebanjwa ngesandla) 2*1.5VAAA ibhetri eyomileyo (Isikhangeli) |
Ixesha elizinzileyo lokusebenza | ≥12h |
Umgama wothumelo | ≥100m (umbane owaneleyo) |
Bonisa | Umboniso we-LCD, unokuboniswa ngokucacileyo phantsi kokukhanya kwelanga. |
Ubushushu bokusebenza | -35℃---+60℃ |
Ubushushu bokugcina | -40℃---+65℃ |
Ubuntu bezizalwane | ≤90%RH Ayina-condensate |
Hayi. | Ubumbeko olusisiseko | Iyunithi | Qty. | Phawula |
1 | Itheminali ebanjwa ngesandla | iseti | 1 | |
2 | Umtshina ozinikeleyo | iqhekeza | 1 | |
3 | A,B Umtshini | ingcambu | 2 | |
4 | AA Ibhetri eyomileyo (1.5V) | icandelo | 2 | |
7 | AAA Ibhetri eyomileyo (1.5V) | icandelo | 2 | |
8 | Ngenisa ingxowa ephathekayo | iqhekeza | 1 | |
9 | 220kV Intonga ye-insulation | ingcambu | 1 | ≤220kV ihambelana ne4amacandelo4Intonga ye-M insulation,≥330kV dibanisa ne6 amacandelo6Intonga ye-M insulation |
10 | Incwadana yokusebenza | ikopi | 1 | |
11 | Ingxelo yovavanyo | ikopi | 1 | |
12 | Ikhadi lewaranti | ikopi | 1 | |
13 | Uluhlu lokupakisha | ikopi | 1 |