GD3127 Series High Voltage Insulation Resistance Tester
I-GD3127 Series Insulation Resistance Tester isetyenziswa ngokubanzi ekugcinweni kwezixhobo zombane kwi-transformer substation, iplanti yamandla, njl njl. Ifanelekile ukuphumeza umlinganiselo wokumelana nokufakelwa (IR), isalathisi se-polarization (PI), umlinganiselo wokufunxa (i-DAR), i-ramp ( I-RAMP), isihluzi (FR, 10s, 20s, 30s, 40s 4 choices), i-voltage (V), yangoku (nA) yazo zonke iintlobo zezixhobo zombane ophezulu, kubandakanya i-switchgear, i-transformers, i-reactors, i-capacitor, ii-motor, iijeneretha kunye neentambo, njl.
I-GD3127 Series sisixhobo sovavanyo esigqibeleleyo sokuchongwa kwangethuba kunye nokufunyanwa kwezicwangciso zothintelo okanye zokuqikelela ukugcinwa kokusilela kwezixhobo ezinokwenzeka.Kubaluleke kakhulu ukuqinisekisa umgangatho wemveliso kunye nokhuseleko lwabantu kunye nezixhobo zokusebenza.Ukusebenza kwe-insulation yeemveliso zombane yenye yeempawu ezibalulekileyo zokuvavanya umgangatho we-insulation, obonakaliswa ngovavanyo lokumelana nokukhusela.
●Max.yangoku emfutshane >5mA.
●Ukumelana ne-Insulation (IR), i-polarization index (PI), i-absorption ratio (DAR).
●Irempu (RAMP), isihluzi (FR), amandla ombane (V).
●Ukubeka iliso ngokuzenzekelayo umbane ophilayo wento elinganisiweyo, kwaye unqande ngokuzenzekelayo uvavanyo ukuba i-voltage idlula i-36V, ekhusela ngokufanelekileyo isixhobo kunye nomqhubi.
●Umsebenzi wexesha, urekhoda ngokuzenzekelayo ixesha lovavanyo.
●Ukuzikhupha ngokuzenzekelayo i-voltage ephezulu emva kokuba umlinganiselo ugqityiwe, ixesha lokukhutshwa alikho ngaphezu kwemizuzwana engama-30.
●Ukucima umsebenzi ozenzekelayo.
●Isikrini esikhulu se-LCD se-matrix ye-matrix ebonisa ukusebenza okuzinzileyo.
●Ulwakhiwo lweqokobhe oluneqokobhe eliphindwe kabini, lomelele kwaye lomelele, ibakala lokhuseleko IP65.
●Umthamo omkhulu wepakethi yebhetri ye-lithium etshajwayo.
●Umsebenzi wokugcina, unokugcina ngokuzenzekelayo iiseti ze-1000 zedatha yovavanyo lwexesha lokwenyani kunye nomhla wovavanyo kunye nexesha kunye nexesha lovavanyo.
●Umsebenzi wokulayisha, uxhotyiswe nge-interface ye-USB, idatha yokurekhoda ingalayishwa kwikhompyutheni ukuze ihlalutye idatha yedatha.
| Umsebenzi | Ukumelana ne-Insulation (IR), i-polarization index (PI), i-absorption ratio (DAR), i-ramp (RAMP), i-filter (FR, 10s, 20s, 30s, 40s 4 ukhetho), i-voltage (V), yangoku (nA) |
| Ukunikezwa Amandla | Iyatshajwa kwakhonaibhetri ye-lithium5.2Ah |
| Umbane olinganisiweyo | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
| Imveliso yombane aukuchaneka | (5%-10%)±10V |
| Uluhlu lokulinganisa ukumelana ne-insulation | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
| Isiphaluka esifutshane sangoku | >5mA |
| Polarization index(PI) | Ewe |
| Umlinganiselo wokufunxa (DAR) | Ewe |
| I-Ramp (RAMP) imo yokuvavanya | Uvavanyo lwamanyathelo e-10% yombane osele usetwe kude kube yivolthi esetwe kwangaphambili |
| Imowudi yovavanyo lwesihluzi | Ukukhetha okune kwe-10S, 20S, 30S, 40S |
| Uvavanyo lwamandla ombane | Uluhlu: AC/DC 0V-1000V, ukuchaneka:±5%rdg±3V |
| Uvavanyo lwangoku | Uluhlu: 0.01nA-7mA, ukuchaneka:±5%rdg±0.5nA |
| Imonitha yombane | Ukubeka iliso kumbane wento evavanyiweyo, jonga imeko yokukhutshwa emva kovavanyo, kwaye uthintele uvavanyo xa i-voltage ingaphezulu kwe-36V, khusela isixhobo kunye nomsebenzisi. |
| Isibali-xesha sovavanyo | Rekhoda ixesha lovavanyo ngokuzenzekelayo, uluhlu lwexesha: 0s~9999s |
| Ugcino | Ukugcinwa ngokuzenzekelayo kwedatha yovavanyo kunye nomhla kunye nexesha, inani lamaqela angama-1000 |
| Unxibelelwano | Layisha idatha yovavanyo egciniweyo kwikhompyuter ngentambo yonxibelelwano ye-USB. |
| Ibhetri | Kukho umboniso wezinga lebhetri, okukhumbuza ukutshaja ngexesha xa amandla ombane ebhetri ephantsi |
| Auto ukucima umsebenzi | Umbane ozenzekelayo ucinywe emva kwemizuzu eyi-15 |
| Iklasi yokhuseleko | IP65/IP40 |
| Ukumelana ne-insulation | 50MΩ(1000V) (phakathi kwesekethe yovavanyo kunye neqokobhe) |
| Ukumelana nombane | I-AC 3kV 50Hz 1min (phakathi kwesekethe yovavanyo kunye neqokobhe) |
| Imigangatho | IEC61010-1, IEC61326-1 |
| Ubushushu bokusebenza kunye nokufuma | - 20℃ ~ +50℃ <80I-%RH |
| Ubushushu bokugcina kunye nokufuma | - 25℃ ~ +65℃80%RH |
| Ukunikezwa Amandla | 220V AC 50Hz |
| Ubungakanani (mm) | 280(L)*260(W)*160(H) |
| Ubunzima | 4400g(kuquka ibhetri) |
| Umvavanyi wokumelana ne-insulation | Iseti e-1 |
| Ucingo lokuvavanya amandla ombane aphezulu (Bomvu) | 1 iqhekeza |
| Ucingo lokuvavanya(Luhlaza) | 1 iqhekeza |
| Uvavanyoucingo(Mnyama) | 1 iqhekeza |
| Iadaptha yamandla | 1 ipheiece |
| Umsebenzisi's isikhokelo | Ikopi enye |
| Uvavanyori-eport | Ikopi enye |