GDSL-D Series Digital Primary yangoku iSeti yoVavanyo lwesitofu
●I-DL/T 596-2005 "Iinkqubo zoVavanyo lweNkqubo yeSixhobo soMbane"
●I-GB1094.1-GB1094.6-96 "inqanaba lokukhusela i-Shell"
●GB2900 "Isigama soMbane"
●I-GB/T16927.1 ~ 2-1997 "Itekhnoloji yoVavanyo lweVoltage ephezulu"
●I-GB4793-1984 "IiMfuno zoKhuseleko kwizixhobo zokulinganisa i-Electronic"
●I-GB191 "iPhakeji yokuGcina kunye noPhawu loThutho"
●I-GB/T.311-1997 "I-Insulation kunye nokulungelelaniswa kokuhanjiswa kwamandla ombane aphezulu kunye nezixhobo zokuguqula"
●Ukusebenzisa i-copper conductivity ephezulu njenge-electrode ephumayo, indawo yoqhagamshelwano inkulu kwaye umthamo wokuhamba unamandla.
●Ipleyiti yealuminiyam ebhrashiweyo enenkqubo entsha, ilula kwaye itsala amehlo, ayigugi kwaye ixhathisa ungcoliseko.
●Icala leplastiki yokutshiza yesinyithi kunye nethoni engwevu yekamela eyaziwayo kumazwe ngamazwe iqinile kwaye inokwethenjelwa, iqinisekisa ukuthembeka kwezinto.
●Ukusetyenziswa kwe-brake casters yendalo yonke kwenza intshukumo kunye nokulungisa kube bhetyebhetye kwaye kulula.
●Umbhobho wokuhamba komoya omile okwe-Wedge ukuphucula ukuchithwa kobushushu kunye nokwandisa kakhulu ubomi benkonzo.
●Umatshini wonke uncinci ngobukhulu kwaye ulula ngobunzima, obufaneleke kakhulu ukusetyenziswa kwentsimi.
●Inomsebenzi wokukhusela i-zero ukukhusela impembelelo yangoku enkulu ebangela umonakalo kwisampuli.Ayinakuqalwa xa ingekho kwindawo engu-zero.
●Umsebenzi wokukhetha impembelelo, xa uvavanyo lwe-circuit breaker-breaker breaker lwenziwa, umsebenzi wokukhusela i-zero unokunqunyulwa kwaye ixabiso langoku elifunekayo linokuphuma ngokuthe ngqo.
●Imo yemveliso yangoku: Ixabiso lokwenyani le-RMS lihlengahlengiswa ngokuqhubekayo.
●Imveliso yangoku yi-sine wave esemgangathweni, kwaye isantya sokuguqulwa kwamaza singaphantsi kwe-5%.
●I-voltage kunye nomboniso wangoku wamkelaumboniso omtsha wedijithali ochanekileyo ophezulu we-LED
●Ubungakanani obutshintshekayo boluhlu lwangoku lokuphucula ukulunga kokubonisa ufundo oluchaneke ngakumbi.
●Umbane wobonelelo lwamandla kunye nombane wokuphuma komlawuli unokutshintshwa ukuze ubonise ukujonga lula.
●Umthamo wezixhobo zenzelwe ixesha elifutshane, umsebenzi ophazamisayo kwimizuzu emi-5.
●Ukuvavanya ibhetshi, vala imizuzu eyi-10 emva kwemizuzu eyi-2.5 yokusebenza ngokuqhubekayo.
●Inokulinganisa ixesha langoku lesenzo secandelo elivavanyiweyo kwaye irekhode ixesha lesenzo sokutshixa ngolungelelwano.(ukhetho)
●Uluhlu lwexesha elilinganisiweyo: 0.001S~999.999S Isisombululo 1ms, impazamo yokulinganisa: 0.005% uluhlu ± 2digs.(ukhetho)
●Ixabiso lovavanyo lweprayimari yangoku kunye nesekondari yangoku inokuboniswa ngokuthe ngqo ukuququzelela uvavanyo lomlinganiselo we-transformer.(ukhetho)
●Uluhlu lwangoku lwesibini 0~5A isisombululo 1mA (ukhetho)
●Ukuba ukunyuka kwamaqondo obushushu (imizuzu engama-30 - iiyure ezingama-24) kufuneka kulungiselelwe ngokuhambelana nokunyuka kwexesha elide lomsebenzi.(ukhetho)
●Inokwenziwa ngokwezifiso inqanaba lesithathu kunye ne-balance adjustment riser (ukhetho)
●Ingenziwa ngokwezifiso i-AC kunye ne-DC riser (ukhetho)
| Umzekelo | Umthamo wemveliso(kVA) | Imveliso yangoku(A) | Ukunikezwa Amandla(V) | Vula i-voltage yesiphaluka(V) | Pisigaba sokuqala | Phawula | |
| GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
| GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
| GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
| GDSL-D-2000 | 12 | 2000 | 220 okanye 380 | 6 | LN | AB | Integrated okanye indibaniselwano |
| GDSL-D-2500 | 15 | 2500 | 220 okanye 380 | 6 | LN | AB | Integrated okanye indibaniselwano |
| GDSL-D-3000 | 18 | 3000 | 220 okanye 380 | 6 | AB | Integrated okanye indibaniselwano | |
| GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | indibaniselwano | |
| GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | indibaniselwano | |
| Ingenziwa ngokwezifiso ngenxa yeemfuno ezizodwa zomthengi | |||||||
| Iseti yovavanyo olusisiseko lwangoku | Iqhekeza eli-1 |
| Ikhodi yamandla | Iqhekeza eli-1 |
| Ucingo Lokuthoba | Iqhekeza eli-1 |
| Umgca wangoku ophezulu(umgangatho 2m) | 2 iqhekeza |
| Isatifikethi | Ikopi enye |
| Imanyuwali | Ikopi enye |
| Uluhlu lokupakisha | Ikopi enye |
| Ingxelo yoVavanyo | Ikopi enye |