GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
● Yamkela i-microprocessor ukugqiba ngokuzenzekelayo imisebenzi yokunyusa, ukubamba, ukuvuselela, i-static, ukubala, ukuprinta, njl., kwaye inokwenza ukujikeleza kweoli ukumelana novavanyo lwe-voltage kuluhlu lwe-0-80 kV.
● Isikrini esikhulu se-LCD sokuchukumisa.Izaziso zemenyu yesiTshayina kunye nesiNgesi ezitshintshayo;imbonakalo entle kunye nobukhulu obuncinci.
● Isixhobo silula ukusebenza, umqhubi ufuna kuphela ukwenza isicwangciso esilula, kwaye isixhobo siya kugqiba ngokuzenzekelayo uvavanyo lokumelana nombane we-1 indebe yesampuli yeoli ngokwemimiselo.Ixabiso le-voltage yokuqhawula kunye nenani lemijikelezo ye-1 ukuya kumaxesha e-10 agcinwa ngokuzenzekelayo.Emva kokuba uvavanyo lugqityiwe, umshicileli we-thermal unokuprinta amaxabiso ombane wokudiliza kunye namaxabiso aphakathi.
● Imigangatho yokwenziwa kovavanyo lwesixhobo ibandakanya imigangatho yoshishino, imigangatho yesizwe kunye nemigangatho ye-IEC60156, kwaye ukusebenza kulula kwaye kulula.
● Ngokubamba umbane, iziphumo zovavanyo ezili-100 zinokugcinwa kwaye ubushushu obukhoyo kunye nokufuma kungaboniswa.
● Nge-over-voltage, over-current, limit and other protection ukuqinisekisa ukhuseleko lwabaqhubi.
● Ngomsebenzi wokubonisa umlinganiselo wobushushu kunye nomboniso wewotshi yenkqubo.
● I-Standard RS232 interface, inokunxibelelana nekhompyutha.
● Ujongano lwe-USB, luyakwazi ukuthumela ngaphandle idatha yovavanyo.
| Umbane ophumayo: | 0-80kV(uyazikhethela) |
| Isantya sokuphazamiseka kwamandla: | <3% |
| Umthamo: | 1.5kVA |
| Ukuchaneka komlinganiselo: | ±3% |
| Yeka ukonyusa amandla ombane: | 10 ~ 80kV adjustable |
| Ixesha elimileyo: | 0-15 imizuzu adjustable |
| Ixesha lokunyuswa kwe-voltage: | 0-5 imizuzu adjustable |
| Ixesha lokuphumla: | 0-120 imizuzwana adjustable okanye ngokuqhubekayo |
| Amaxesha okunyusa amandla ombane: | 1-10 amaxesha adjustable |
| Amandla okunyusa amandla ombane: | 0.5kV/s-5.0kV/s adjustable |
| Ungeniso lwamandla: | AC220V± 10%, 50Hz/60Hz±1Hz |
| Amandla: | 200W |
| Ubushushu bokusebenza: | 0-45℃ |
| Ukufuma: | <75%RH |
| Ubungakanani: | 460*280*320mm |
| Isixhobo se-GDOT-80A | 1pc |
| Indebe yeoli | 1pc |
| Ikhodi yamandla | 1pc |
| Intambo ephantsi | 1pc |
| I-fuse esecaleni | 2pcs |
| Ingqiniba | 2pcs |
| Igeyiji eqhelekileyo | 1pc |
| Hexagon wrench | 1pc |
| I-Tweezers | 2pcs |
| Ukuvuselela i-nut | Imiqulu emi-2 |
| Iphepha lokuprinta | 1pc |
| Isikhokelo somsebenzisi | 1pc |
| Ingxelo yovavanyo lwasefektri | 1pc |