I-GDCR-3200C I-Double Clamp Multifunctional Earth Resistance Tester
I-GDCR3200C i-Double Clamp Multifunctional Earth Resistance Tester iyilwe ngokukodwa kwaye yenzelwe umlinganiselo wesiza wokumelana nomhlaba, ukumelana nomhlaba, amandla ombane omhlaba, ukuvuza komgca osezantsi, i-AC yangoku kunye nokuxhathisa kwe-DC.Isixhobo samkela iteknoloji yokucubungula idijithali, kunye ne-2-wire method, indlela ye-3-wire, indlela ye-4-wire, indlela yokukhetha, indlela ye-clamp ephindwe kabini kunye nezinye iindlela zokulinganisa;Ngenisa iteknoloji ye-FFT (i-Fast Fourier Transform), iteknoloji ye-AFC (i-Automatic Frequency Control), enobuchule obukhethekileyo bokuchasana nokuphazamiseka kunye nokulungelelaniswa kwendalo, ukuhambelana okuphindaphindiweyo kovavanyo, ukuqinisekisa ukuchaneka okuphezulu, ukuzinza okuphezulu kunye nokuthembeka okuphezulu kokulinganisa ixesha elide.Isixhobo esisetyenzisiweyo. uyilo olukhulu lwe-clamp yangoku, inokujongana nazo zonke iintlobo zeemfuno zovavanyo, inokulinganisa ixabiso lokuxhathisa lobungakanani obukhulu obuphantsi komhlaba, bhetyebhetye ukulinganisa ixabiso lokumelana nomgangatho wenqaku elinye kunye nokubekwa kwegridi kunye nazo zonke iintlobo zesakhiwo esintsonkothileyo sokumisa, akukho mfuneko yokuqhawula naluphi na uxhulumaniso oluhambelanayo lwepali yomhlaba xa ulinganisa inkqubo yokumisa i-parallel, iphucula kakhulu ukulungelelaniswa komlinganiselo, kuba uvavanyo lokusebenza komhlaba lubonelela ngesisombululo esifanelekileyo.
I-GDCR3200C i-Double Clamp Multifunctional Earth Resistance Tester yenziwe ngumatshini wokubamba, ibamba langoku (ibamba eliphindwe kabini), iingcingo zovavanyo, intonga yomhlaba oncedisayo, isoftwe yedatha kunye neengcingo zonxibelelwano njalo njalo.Umboniso omkhulu we-LCD we-host machine ene-backlight emhlophe kunye ne-bar yegrafu ebonisa ngokucacileyo.Umhloli unomsebenzi wokugcina, umsebenzi wewashi, kwaye ugcina ngokuzenzekelayo amaqela angama-2000 eziphumo zovavanyo eziqulethe umhla kunye nexesha.Umvavanyi kunye nomsebenzi wonxibelelwano weBluetooth oxhasa inkqubo ye-Android.Emva kokufakwa kwe-APP, unokuvavanya okanye ufunde iirekhodi zovavanyo kwi-terminal yeselula, ukuzisa amava amatsha.Umvavanyi uxhobisa ujongano lwe-USB, kunye nedatha egciniweyo ingalayishwa kwiPC ngojongano lwe-USB.Isoftware yonxibelelwano inokuqonda imisebenzi yokufunda, ukubonisana, ukonga, ukunika ingxelo kunye noshicilelo lwedatha yerekhodi yembali.Isetyenziswe ngokubanzi kumandla, unxibelelwano, i-meteorology, indawo yeoli, ukwakhiwa, ukhuseleko lombane kunye nezixhobo zombane zemizi-mveliso.
●Uyilo olulodwa lokukhanya kwesalathisi se-jack, isibonakaliso esichanekileyo sendawo yejack, ukuphepha impazamo yokusebenza.
●Iqhosha lokukhetha umsebenzi weGears, iindlela ezahlukeneyo zovavanyo ziyaboniswa, zenza umsebenzi ube lula kwaye ukhawuleze.
●Umvavanyi unomsebenzi wonxibelelwano lweBluetooth kwaye uxhasa inkqubo ye-Android.Abasebenzisi banokusebenzisa i-terminal yeselula ukuvavanya ukusebenza okanye ukufunda iziphumo zovavanyo eziqulethe umhla kunye nexesha ngokulula kakhulu.
●Icala lesixhobo lithatha ibhokisi lokukhusela elingenamanzi, elinamandla, elikhuselekileyo kwaye lihlala lihlala linqanda ukungqubuzana, ukuchasana nokuwa kunye nokungena kwamanzi (ibakala lokukhusela i-IP65), elilungele ukusetyenziswa kwiindawo zokwakha zangaphandle.
●Imitha ixhotyiswe ngepakethi yebhetri yelithium etshajwayo.Kwaye kunye nojongano lwe-USB ukulayisha umsebenzi wedatha.
Iimeko ezisisiseko kunye neemeko zomsebenzi
| Ubungakanani bempembelelo | Imeko esisiseko | Iimeko zokusebenza | Phawula |
| I-Ambient Temp | 23℃±1℃ | -10℃-40℃ | ---- |
| Ukufuma kwe-Ambient | 40%-60% | <80% | ---- |
| I-Voltage esebenzayo | 7.8V±0.1V | I-DC 7.8V±0.6V | ---- |
| Ukuxhathisa Umhlaba oNcedisayo | <100Ω | <5kΩ | |
| Ukuphazamiseka kweVoltage | Kufuneka uphephe | <20V | |
| Uphazamiseko lwangoku | Kufuneka uphephe | <2A | |
| Umgama we-Electrode xa ulinganisa i-R | a>5d | a>5d | |
| Electrode Umgama xa kusenziwa umlinganiselo ρ | a>20h | a>20h |
Iinkcukacha ngokubanzi
| Umsebenzi | Ukulinganisa ukuxhathisa umhlaba, ukumelana nomhlaba;Ukuxhathisa kweDC, amandla ombane omhlaba, alternating current, ukuvuza kwangoku | |
| Ukunikezwa Amandla | I-DC 7.4V 2600mAh ibhetri ye-lithium egcwalisekayo, igcwele malunga ne-8.4V | |
| Isibane ngasemva | Isibane esilawulekayo sesikrini, silungele iindawo ezimfiliba | |
| Indlela yokulinganisa | Ukuxhathisa kweDC | Uxhathiso lwe-DC-2-wire method |
| Uxhathiso lwe-DC-4-wire method | ||
| Ukuxhathisa umhlaba | Ukuxhathisa umhlaba indlela ye-2-wire | |
| Ukuxhathisa umhlaba indlela ye-3-wire | ||
| Ukumelana nomhlaba indlela ye-4-wire | ||
| Ukuxhathisa umhlaba indlela enye yocingo olu-3 (indlela yokukhetha) | ||
| Ukuxhathisa umhlaba enye indlela yokubamba i-4-wire (indlela yokukhetha) | ||
| Ukumelana noMhlaba double ndlela yokubamba | ||
| Ukuxhathisa umhlaba (indlela yeWenner) | ||
| Umhlaba wangoku | Umlinganiselo wangoku wokubamba | |
| Amandla ombane omhlaba | Ulungiso oluphakathi | |
| Uvavanyo lweVoltage Wave | Sine wave | |
| Vavanya Ukuphindaphinda | 128Hz/111Hz/105Hz/94Hz(AFC) | |
| Uvavanyo lwexesha elifutshane lwangoku | AC 250mA max | |
| UVavanyo oluvulelekileyo lwangoku | AC 40V max | |
| Electrode Distance Range | 1m-100m | |
| Imo yokubonisa | 4-digital enkulu LCD ukubonisa, kunye nescreen backlight | |
| Isalathisi somlinganiselo | Ngexesha lokulinganisa, isalathisi se-LED, i-LCD countdown display | |
| LCD isakhelo Dimension | 128mm×75mm | |
| Indawo yokubonisa i-LCD | 124mm×67mm | |
| Ubungakanani besixhobo | 280mm(L) X 260mm(W) X 160mm(H) | |
| CT Ubungakanani | 223mm X 120mm X 39mm | |
| Test Wire | Iingcingo ezi-4: nganye ibomvu 20m, emnyama 20m, tyheli 10m, kwaye eluhlaza 10m | |
| Uvavanyo olulula ucingo | Iingcingo ezi-2: nganye ibomvu yi-1.6m kunye ne-1.6m emnyama | |
| Intonga encedisayo yokuGrounding | 4PCS: Φ10mm X150mm | |
| I-Clamp yangoku | I-2PCS : Iplagi ye-blue-black kunye ne-1 iplagi ebomvu-emnyama | |
| I-Clamp Caliber | Φ70mm | |
| Clamp Lead Wire | 2m | |
| Umlinganiselo wokulinganisa | I-AC yangoku: malunga namaxesha ama-2 / ngomzuzwana | |
| Umbane woMhlaba: malunga namaxesha ama-2 / ngomzuzwana | ||
| Ukumelana nomhlaba: malunga nemizuzwana ye-7 / ixesha | ||
| Ukulinganisa Amaxesha | Ngamaxesha angama-5000 (uvavanyo lwesekethe emfutshane, ixesha lekhefu kufuneka libe yimizuzwana engama-30 ubuncinci) | |
| Umbane womgca | Umlinganiselo ongaphantsi kwe-AC 600V | |
| INxibelelwano yoNxibelelwano | Imodyuli yeBluetooth, ujongano lwe-USB, idatha yokugcina inokulayishwa kwikhompyuter, igcinwe okanye iprintwe. | |
| Ucingo loNxibelelwano | Intambo yonxibelelwano ye-USB x1pcs, enobude obuyi-1.5m | |
| Ukubamba Idatha | Umsebenzi wokubamba idatha: "BAMBA" isiboniso sesimboli | |
| Ukugcinwa kwedatha | Amaqela angama-2000, "MEM" isalathisi sogcino, "FULL" isimboli sokugcina isiboniso sogcino sigcwele | |
| Ukufikelela kwiDatha | Umsebenzi wokufundwa kwedatha: "FUNDA" umboniso wesimboli | |
| Umboniso oPhuphumayo | Ukugqithisa umsebenzi wokuphuphuma komlinganiselo woluhlu: "OL" bonisa uphawu | |
| Isalathisi sangoku esiPhantsi sebamba langoku | Ukulinganisa ngendlela yokukhetha okanye iqhosha eliphindwe kabini, isibonakaliso sangoku esifunyenwe yi-CT2 singaphantsi kwe-0.5mA, siya kubonisa "", kwaye kufuneka sihlolisise isalathiso sokubambelela se-CT2 yangoku. | |
| Uvavanyo longenelelo | Ukuchongwa okuzenzekelayo kweempawu zophazamiseko, uphawu lwe "NOISE" xa umbane wokuphazamiseka ungaphezulu kwe-5V | |
| Uvavanyo oluNcedisayo lokuGrounding | Ngomsebenzi oncedisayo wokuvavanya ukuxhathisa, 0.00KΩ-30kΩ (100R+rC<50kΩ, 100R+rP<50kΩ) | |
| Umsebenzi weAlam | Ixabiso lokulinganisa ligqithise ixabiso lokumisela i-alam, liyakwenza isandi se-alam ethi "Toot-toot-toot". | |
| Umbane webhetri | Ngelixa amandla ombane ebhetri ehla aye malunga ne-7.2V±0.1V, iya kubonisa isimboli yombane webhetri ephantsi, kwaye ikhumbuza ukutshintsha ibhetri. | |
| Ukucima okuzenzekelayo | Vala ngokuzenzekelayo emva kwemizuzu eyi-15 yombane | |
| Ukusebenza Ngoku | Isibane sangasemva: 25mA Max (ukusetyenziswa kombane ngasemva kuphela) | |
| Ukulinda: 25mA Max(Isibane sangasemva sicinyiwe emva kokukhanya kombane) | ||
| Umlinganiselo:150mA Max (Isibane sangasemva sivaliwe) | ||
| Ubunzima | Umvavanyi: 2290g | |
| Ubambo lwangoku:1100g(2pcs) | ||
| Ubunzima bubonke: 6800g(bandakanya zonke izincedisi) | ||
| Ubushushu bokusebenza kunye nokufuma | -10℃-40℃, ngaphantsi kwe-80%rh | |
| Ubushushu bokugcina kunye nokufuma | -20℃-60℃, ngaphantsi kwe-70%rh | |
| Inqanaba loKhuseleko | IP65(vala ityala) | |
| uKhuseleko lomthwalo ogqithisileyo | Yenza umlinganiselo wokuchasa umhlaba: phakathi kothungelwano ngalunye lwe-C(H)-E,P (S)-ES, AC 280V/3 imizuzwana | |
| I-Insulation Resistance | Ngaphezulu kwe-20MΩ(phakathi kwesekethe nangaphandle kweqokobhe yi-500V) | |
| Ukumelana neVoltage | AC 3700V/rms.(Phakathi kwesekethe nangaphandle kweqokobhe) | |
| Iimpawu ze-Electromagnetic | IEC61326(EMC) | |
| Uhlobo loKhuselo | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,Ungcoliseko 2); IEC61010-031; IEC61557-1 (Ukuchasana noMhlaba); IEC61557-5(ukumelana nomhlaba); I-JJG 366-2004(Imitha yokumelana nomgangatho) I-JJG 1054-2009(Imitha yokumelana neClamp) | |