GD-3134E abavavanyi beCable kunye nesichongi seCable
I-GD-3134E yinkqubo yokukhangela imibhobho yentsimbi esebenza kakhulu ephantsi komhlaba eyenziwe ngabathumeli bomqondiso kunye nabamkeli.Ingasetyenziselwa ukukhangela indlela, uphando lwemibhobho kunye nokulinganisa ubunzulu bemibhobho yesinyithi kunye neentambo ezingaphantsi komhlaba.Iyakwazi ukuphumeza ukuchongwa okukodwa kunye neentlobo zezixhobo ezikhethiweyo, kunye nomonakalo wokufakela umbhobho kunye nokukhangela ezinye iintlobo zeempazamo zekhebula.
●Umboniso wekhampasi: ubonisa ngokubonakalayo indawo yombhobho kunye nezalathiso zasekhohlo nasekunene.
●Ukulandelela okuyinyaniso kunye nobuxoki: umlinganiselo wesalathiso wangoku, ukulandelela impazamo echanekileyo, ukuphelisa ukuphazamiseka komgca (amanye amaza).
●Ubunzulu kunye nemilinganiselo yangoku, ingabonisa amandla omqondiso igophe lembali.
●Ukusetyenzwa kwesampulu echanekileyo yedijithali ngokupheleleyo: izinzile kwaye zithembekile, ubuntununtunu be-ultra-high, i-passband emxinwa yokufumana, isakhono esinamandla sokuchasana nokuphazamiseka, sinokucinezela ngokupheleleyo amandla ombane kunye nokuphazamiseka kwe-harmonic yeentambo ezisebenza ngokusondeleyo kunye nemibhobho.
●Ukubona ikhebula ebalekayo: i-clamps yokuhanjiswa kwentsebenzo ephezulu, isignali ephezulu yokudibanisa imveliso kwintambo esebenzayo.
●Ukuchongwa kwekhebula/umbhobho: Izibane eziguquguqukayo (ukuzikhethela) kulula ukuzisebenzisa kwaye zinika ngokucacileyo iziphumo zokuchongwa;i-stethoscopes (ukhetho) lunokusetyenziswa xa kungenakulungele ukusebenzisa i-clamps.
●Ukufunyanwa kwempazamo ephantsi: I-booster ye-HV (ukhetho) yonyusa amandla ombane aphezulu ukuya kwi-1000V, isebenzisa isakhelo se-A (ukhetho) ukukhangela iindawo zokwaphuka kwe-insulation yomhlaba zombhobho, akukho mfuneko yokulungelelanisa i-zero.Utolo lubonisa icala lendawo yempazamo.
●Iifrikhwensi zokubona ezininzi: ubhaqo olusebenzayo kunye nokubonwa kokwenziwa.
●Iindidi ezahlukeneyo zemveliso ye-transmitter: isiphumo sokuqhagamshelwa ngokuthe ngqo, ukuphuma kwe-clamp coupling, i-radiation induction.
●Ukukhutshwa kwamandla aphezulu kwi-transmitter, iziphumo ezininzi ezinokuhlengahlengiswa, ukulinganisa okuzenzekelayo kunye nokukhusela.
●Iqela lebhetri elakhelwe kwi-lithium ion enkulu, iya kucinywa ngokuzenzekelayo okanye ingasebenzi ixesha elide,
●Icasi enqabileyo, ilula kwaye iyaphatheka.
Isidluliseli
●Iimowudi zemveliso: imveliso yoqhagamshelo oluthe ngqo, ukwenziwa ngemitha, ukuphuma kokudibanisa iqhosha (ukhetho), impazamo yokufumana i-HV booster (ukhetho).
●Ubuninzi bemveliso: 640Hz (i-compound frequency), 1280Hz (i-compound frequency), 10kHz, 33kHz, 82kHz, 197kHz.
●Amandla emveliso: Max.10W, iigiya ezili-10 ezilungelelanisiweyo, ukuhambelana kwe-impedance ngokuzenzekelayo.
●Umbane wokuphuma ngokuthe ngqo koqhagamshelwano: ubuninzi be-150Vpp.
●Ukugqithiswa kunye nokukhusela isiphaluka esifutshane.
●Ujongano lomatshini womntu: 320 x240 dot matrix LCD ukubonisa.
●Ibhetri eyakhelwe-ngaphakathi: i-4 icandelo le-18650 lithium ion ibhetri, igama elithi 7.4V, 6.8Ah.
Umamkeli
●Imowudi yokufaka: Ikhoyili yokufumana eyakhelweyo, i-flexible clamp-on CTs (ukhetho), iStethoscope (ukhetho), Uhlobo lwesixhobo sokubona impazamo (ukhetho).
●Ukufumana rhoqo:
Ukufunyanwa okusebenzayo kwimibhobho: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
I-frequency frequency yokufumanisa i-passive frequency: 50Hz / 60Hz kunye ne-250Hz / 300Hz (umsebenzisi oqwalaselweyo).
I-RF i-passive yokufumanisa i-frequency: i-frequency center yi-10kHz, i-33kHz, i-83kHz ngokulandelelanayo.
●Imowudi yokufumanisa umbhobho: Indlela ebanzi yencopho, indlela yencopho emxinwa, indlela yeValley yesandi.
●Imowudi yokuchonga ikhebula: i-flexible clamp-on CTs(ukuzikhethela) ukuchongwa okuzenzekelayo kunye nomlinganiselo wangoku, ukuchongwa kwe-stethoscope(okukhethwa kukho).
●I-320 * 240 i-LCD ukubonisa, ibonisa i-amplitude yesignali, isalathisi ekhohlo / ekunene, isalathisi esichanekileyo / esingeyonyani, ijika lembali yamandla omqondiso, ubunzulu, okwangoku kunye nesiphumo.
●Ibhetri eyakhelwe-ngaphakathi, i-2 icandelo le-18650 lithium ion ibhetri, ilinganiswe i-7.4V, i-3.4Ah.
Abanye
●Ubungakanani: Transmitter 280 * 220 * 90mm.Umamkeli 680*270*120mm.
●Ubunzima: Transmitter 2.2kg.Umamkeli 3.5kg.
●Itshaja: AC100-240V igalelo, 50/60Hz, imveliso DC 8.4V, 2A/3A.
●Imeko yokusebenza: Ubushushu -10-40 ℃, Ukufuma 5-90% RH, ukuphakama<4500m.
Isidluliseli
![]() | ![]() |
| I-Transmitter iyonke | Transmitter keyboard |
| 1. Umboniso we-LCD 2. Ikhibhodi 3. Isiphumo socket 4. Isokethi yokutshaja | 5. Amandla ON/OFF 6. Iqhosha lokukhupha kwakhona 7/8.Imveliso yokunciphisa amandla / iqhosha lokunyusa 8/9.Ukunciphisa amaxesha amaninzi/ukunyusa iqhosha |
Umamkeli
![]() |
|
| Umamkeli jikelele | Ikhibhodi yomamkeli |
| 1. Umboniso we-LCD 2. Ikhibhodi 3. Fumana uhlengahlengisongeiqhina 4. Isokethi yokutshaja 5. I-accessory input socket | 6. Tshintsha/Thulisa isitshixo 7. Iqhosha lemowudi 8. Iqhosha lokunciphisa amaxesha amaninzi 9. Isitshixo sokunyusa rhoqo 10. Iqhosha lokulinganisa 11. Isitshixo sokulinganisa |
Izincedisi eziqhelekileyo
| Hayi. | Igama | Imizobo kunye nemiyalelo | Qty. |
| 1 | Intambo yoqhagamshelo oluphuma kwi-Transmitter | ![]() | 1 |
| 2 | Grounding drill | ![]() | 2 |
| 3 | Umgca wolwandiso womhlaba | 1 | |
| 4 | Itshaja | Tumgangatho, isidluliselikwayeumamkeli kufuneka ahlawulwe ngokwahlukileyo | 2 |
Izincedisi ozikhethayo (Chaza xa u-odola, ukungachazwanga okumiselweyo akunyulwanga)
| Hayi. | Igama | Imizobo kunye nemiyalelo | Phawula |
| 1 | Cintambo yokuxhuma yomamkeliizixhobo. | ![]() Blue 6-core iplagi | |
| 2 | Cintambo yokuxhuma yeizincedisi transmitter. | ![]() Iplagi ebomvu ye-5-core | |
| 3 | I-Clamp-on CT yokuhambisa | ![]() | |
| 4 | I-Flexible CT yomamkeli | ![]() | |
| 5 | Aisakhelo | ![]() | |
| 6 | Ukufunyanwa kobuphene kwi-HV booster | ![]() | |
| 7 | I-stethoscope encinci | ![]() | |
| 8 | I-stethoscope yesiqu eside | ![]() | |
| 9 | Intonga yokukhangela ye-lkwi-stethoscope yesikhondo | ![]() |



















