info@hvhipot.com
English
CN
Ekhaya
Ngathi
HV HIPOT
Iqela
Imbeko kunye neMfaneleko
Umda woShishino
Umzi-mveliso wethu
Iimveliso
Izixhobo zoVavanyo lwe-Voltage High
Iseti yovavanyo lwe-AC Hipot
Iseti yovavanyo lwe-DC Hipot
Iseti yovavanyo lwe-AC DC yeHipot yoMdibaniso
Inkqubo yoVavanyo lwe-AC Resonant
Iseti yoVavanyo lwe-VLF AC Hipot
Inkqubo yoVavanyo lokukhutshwa kweCorona
Ukwahlula amandla ombane aphezulu
Jika-ukujika Surge Withstand Tester
IsiXhobo soMlinganiselo wokukhupha ngokuyinxenye
Isihlalutyi sokukhupha ngokuyinxenye
Isikhangeli sokukhupha ngokuyinxenye
Ukukhutshwa ngokuyinxenye kuVavanyo lwe-Intanethi
Impulse Voltage kunye neNkqubo yangoku yoVavanyo
Impulse Voltage Test System
Inkqubo yangoku yoVavanyo lweMpulse
Ukuqulunqwa kweNkqubo yoVavanyo lwamaza
Izixhobo zoVavanyo lweTransformer
ICapacitance yeTransformer kunye neTan Delta Tester
Transformer DC Winding Resistance Tester
Umthwalo weTransformer kwaye akukho Mvavanyo woLahleko loMthwalo
Transformer Oli BDV Tester
Transformer Oyile Tan Delta Tester
Ibhentshi yoVavanyo lweTransformer
ITransformer iJika iRetio Tester(TTR Tester)
Transformer Wining Deformation Tester
CT/PT Umlinganiselo kunye noHlalutyo
SF6 Ukufunyanwa kwegesi evuzayo kunye noHlahlelo
I-SF6 ye-Gas Density Relay Calibrator
I-SF6 iGesi evuza iGesi
SF6 Gas Online Monitoring Isixhobo
I-SF6 yoMhlalutyi woMgangatho weGesi
SF6 iGas Recycling System
Switch-gear Test Isixhobo
I-Circuit Breaker Analyzer
Qhagamshelana ne-Resistance Tester
DC Power Supply
Iseti yoVavanyo lwesitofu sangoku
Vacuum Switch Interrupter Vacuity Tester
iCable Fault yokuKhangela inkqubo
Ikhebula kunye neNdawo yombhobho
Inkqubo yeNdawo yeNkalo yeNtembu
Cable Test Van
IsiXhobo sokuBamba uMbane/Isixhobo soVavanyo lwe-Insulator
Umvavanyi we-Insulator
Lightning Arrester Online Test
Umvavanyi woMbane
Umtshina we-Ultrasonic
Relay Protection Tester
Digital Relay Tester
Universal Relay Tester
I-Insulation kunye ne-Earth Resistance Tester
Earth Resistance Tester
Uvavanyo lwe-Insulation Online
I-Insulation Resistance Tester
Umtshina weSigaba
Izixhobo zoVavanyo lwaMandla oMbane
I-Energy Meter Calibrator
Inkqubo yoVavanyo lwemitha yaMandla
Ukuhlaziywa koMgangatho wamandla
Isixhobo soVavanyo lwebhetri
AC kunye DC Power Supply
UkuTshaja ibhetri&Ukukhupha umvavanyi
Umvavanyi weBattery Impedance
Lead Acid Battery Regenerator
Izixhobo zoVavanyo lwe-oyile
IsiHlalutyi seChromatograph yegesi enyibilikileyo
Oli Acid Tester
Umatshini wokuHlunga i-oyile
Oli Flash Point Tester
I-Oli yokuQinisekisa indawo yoMvavanyi
Oli Tension Tester
Oli Trace ukufuma Tester
Isicelo
Ividiyo yokusebenza
Isikhokelo sobuGcisa
Izixhobo zoVavanyo lwe-Voltage High
Iinkonzo
OEM & Customization
Ezinye Iinkonzo ezisondeleleneyo
Iindaba
Imeko eqhelekileyo
Utyelelo loMthengi
Iindaba zeNkampani
Qhagamshelana nathi
Isikhokelo sobuGcisa
Ekhaya
Ezobugcisa
Isikhokelo sobuGcisa
Izilumkiso zokukhusela i-oyile yokuvavanya amandla e-dielectric
ngu admin on 22-12-27
I-GD6100D echanekileyo ye-oyile ye-dielectric ilahleko yokuvavanya i-automatic tester yinto edibeneyo yokugquma i-oyile ye-dielectric loss factor kunye ne-DC resistivity tester ephuhliswe ngokomgangatho wesizwe we-GB/T5654-2007 “Umlinganiselo weRelative Permittivity, Dielectric Loss Factor and DC Resistivity of Liquid Insul...
Funda ngokugqithisileyo
Indima ebalulekileyo yesikhangeli sesigaba kwinkqubo yamandla ombane
ngu admin on 22-12-13
Isixhobo senyukliya esinesigaba sombane esinamandla ombane aphezulu sinomsebenzi oqinileyo wokuchasana nokuphazamiseka, siyahlangabezana neemfuno zemigangatho ye- (EMC), kwaye sifanelekile kumathuba ophazamiseko ohlukeneyo ombane wombane.Isiginali yesigaba esilinganisiweyo se-voltage ephezulu ithathwa ngumqokeleli, iqhutywe kwaye ithunyelwe ...
Funda ngokugqithisileyo
Iingxaki zobugcisa eziqhelekileyo zoMhloli wangoku we-transformer
ngu admin on 22-12-13
Umhloli opheleleyo wangoku weTransformer, owaziwa ngokuba yi-CT / PT Analyzer, sisixhobo sovavanyo esisebenza ngeendlela ezininzi kwisiza esenzelwe ngokukodwa ukukhuselwa kobuchwephesha bovavanyo lweempawu zangoku ze-volt-ampere, uvavanyo lohlengahlengiso kunye ne-polarity discri...
Funda ngokugqithisileyo
Indlela yokujongana nephutha le-transformer yangoku?
ngu admin on 22-12-06
Umthwalo wesibini we-transformer yangoku ichaphazela ngokuthe ngqo ukusebenza kwayo okuchanekileyo.Ngokuqhelekileyo, ubukhulu bomthwalo wesibini, inkulu impazamo ye-transformer.Logama nje umthwalo wesibini ungadluli kwixabiso lokumisela lomenzi, umenzi kufuneka aqinisekise ...
Funda ngokugqithisileyo
ImiGaqo yokuSampula yeChromatographic Analyzer
ngu admin on 22-11-28
Ukuchaneka kweziphumo zovavanyo kunye nokuchaneka kwezigqibo zesigwebo kuxhomekeke ekumeleni kweesampuli ezithathiweyo.Iisampulu ezingamelanga azibangeli nje inkcitho yabasebenzi, izixhobo kunye nexesha, kodwa zikhokelela kwizigqibo ezingalunganga kunye nelahleko enkulu.Iisampulu zeoyile nge sp...
Funda ngokugqithisileyo
Izinto eziluncedo kwiZinc oxide Arresters
ngu admin on 22-11-16
Isakhiwo esisisiseko se-zinc oxide arrester yipleyiti yevalve.Ivalve ye-oxide ye-zinc ifakwe phantsi kombane osebenzayo, kwaye i-current current incinci kakhulu, ngokubanzi i-10 ~ 15μA, kunye neempawu ezingabonakaliyo ze-valve ye-oxyde ye-zinc zenziwa ikakhulu ngumaleko womda wengqolowa.Yona...
Funda ngokugqithisileyo
Iinkqubo zovavanyo ekufuneka zilandelwe xa kusenziwa iimvavanyo zokukhupha inxalenye
ngu admin on 22-11-16
Ngexesha lombane wovavanyo lwe-AC, inkqubo yokulinganisa ukukhutshwa okuqhelekileyo isetyenziswa ngolu hlobo lulandelayo: (1) Isampulu yonyango lwangaphambili Ngaphambi kovavanyo, isampuli kufuneka ilungiswe ngokwemigaqo efanelekileyo: 1. Gcina umphezulu wemveliso yovavanyo ucocekile kwaye womile ukuya thintela izikwere zengingqi zibangele...
Funda ngokugqithisileyo
Ukubaluleka kovavanyo lokuthintela izixhobo zombane
ngu admin on 22-11-10
Xa izixhobo zombane kunye nezixhobo zombane zisebenza, ziya kuba phantsi kwee-overvoltages ezivela ngaphakathi nangaphandle eziphezulu kakhulu kunomlinganiselo oqhelekileyo wombane osebenzayo, okhokelela kwiziphene kwisakhiwo sokugquma izixhobo zombane kunye neempazamo ezifihlakeleyo.Ukuze ufumane ixesha elifanelekileyo ...
Funda ngokugqithisileyo
Ngaba uyazi kangakanani ngentsingiselo yemibala yocingo
ngu admin on 22-11-03
Ukukhanya okubomvu kuyayeka, ukukhanya okuluhlaza kuyahamba, ukukhanya okutyheli kulayitiwe, njalo njalo.Izibane zesignali zemibala eyahlukileyo zibonisa iintsingiselo ezahlukeneyo.Le yingqondo eqhelekileyo ukuba abantwana basenkulisa bayazi.Kwishishini lamandla, iingcingo zemibala eyahlukeneyo zikwamela iintsingiselo ezahlukeneyo.Ububi...
Funda ngokugqithisileyo
Iintlobo zeemvavanyo zokukhupha inxalenye kunye neziza ezifanelekileyo
ngu admin on 22-10-26
Kusenokubakho ukukhutshwa kwenxalenye kwindawo yokufakelwa kwezixhobo zamandla kwiintambo ezitsha ezenziweyo okanye iintambo ekusebenzeni kwexesha elide.Ukuze kubonwe ezo ziphene zokugquma kunye nokuwohloka ngokukhawuleza, iimvavanyo zokukhupha iintambo kwiintambo zinokuthintela kwaye zifumane iingxaki kwaye ziyeke ilahleko kwi ...
Funda ngokugqithisileyo
Umahluko phakathi kwezixhobo eziphambili zombane kunye nezixhobo zesibini
ngu admin on 22-10-26
Umahluko phakathi kwezixhobo eziziiprayimari zombane kunye nezixhobo eziziisekondari: Izixhobo eziziiprayimari zibhekisa kwizixhobo zombane eziphezulu zombane ezisetyenziswa ngokuthe ngqo kwimveliso, ukuhanjiswa nokusasazwa kwamandla ombane.Ibandakanya iijenereyitha, ii-transformer, ii-breakers zesekethe, ii-disconnectors, ...
Funda ngokugqithisileyo
Ziziphi izinto zokuvavanya kwi-transformer esebenzayo?
ngu admin on 22-10-19
Ziziphi izinto zokuvavanya kwi-transformer esebenzayo?I-HV HIPOT GDBT-Transformer Characteristics Comprehensive Test Bench (1) Ukulinganisa ukunyanzeliswa kwe-insulation, i-absorption ratio kunye nokumelana kwe-DC ye-winging.(2) Ukulinganisa ukuvuza kwangoku kunye nokuncipha kwe-dielectric f...
Funda ngokugqithisileyo
<<
< Ngaphambili
1
2
3
4
5
6
Okulandelayo >
>>
Iphepha 2/7
Thumela umyalezo wakho kuthi:
Bhala umyalezo wakho apha kwaye uwuthumele kuthi
Cofa u-enter ukukhangela okanye i-ESC ukuvala
English
French
German
Portuguese
Spanish
Russian
Japanese
Korean
Arabic
Irish
Greek
Turkish
Italian
Danish
Romanian
Indonesian
Czech
Afrikaans
Swedish
Polish
Basque
Catalan
Esperanto
Hindi
Lao
Albanian
Amharic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Bulgarian
Cebuano
Chichewa
Corsican
Croatian
Dutch
Estonian
Filipino
Finnish
Frisian
Galician
Georgian
Gujarati
Haitian
Hausa
Hawaiian
Hebrew
Hmong
Hungarian
Icelandic
Igbo
Javanese
Kannada
Kazakh
Khmer
Kurdish
Kyrgyz
Latin
Latvian
Lithuanian
Luxembou..
Macedonian
Malagasy
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Burmese
Nepali
Norwegian
Pashto
Persian
Punjabi
Serbian
Sesotho
Sinhala
Slovak
Slovenian
Somali
Samoan
Scots Gaelic
Shona
Sindhi
Sundanese
Swahili
Tajik
Tamil
Telugu
Thai
Ukrainian
Urdu
Uzbek
Vietnamese
Welsh
Xhosa
Yiddish
Yoruba
Zulu
Kinyarwanda
Tatar
Oriya
Turkmen
Uyghur