Isixhobo senyukliya esinesigaba sombane esinamandla ombane aphezulu sinomsebenzi oqinileyo wokuchasana nokuphazamiseka, siyahlangabezana neemfuno zemigangatho ye- (EMC), kwaye sifanelekile kumathuba ophazamiseko ohlukeneyo ombane wombane.Isignali yesigaba esiphezulu esilinganisiweyo ithathwa ngumqokeleli, iqhutywe kwaye ithunyelwe ngokuthe ngqo.Ifunyenwe ngesixhobo sesigaba kwaye ithelekiswa nesigaba, kwaye umphumo emva kwesigaba sinobunjani.Ngenxa yokuba le mveliso ikhutshelwa ngaphandle kwamacingo, ikhuselekile ngokwenene, ithembekile, iyakhawuleza kwaye ichanekile, kwaye ifanelekile kwizihlandlo ezahlukeneyo zesigaba.
Isigaba likhonkco elibaluleke kakhulu kubunjineli bamandla ombane.Isixhobo sesigaba se-wireless high-voltage sisixhobo sesigaba esisetyenzisiweyo, esilula, sikhawuleza kwaye sichanekile.Ngokuqhelekileyo, xa zisetyenziswa, ii-cores zesigaba ziphantsi kombane ofanayo, ngokungathandabuzekiyo akukho ngxaki.Ukongeza kungqinisiso lwesigaba esiqhelekileyo kwinqanaba lombane ofanayo, isixhobo sokuqinisekisa isigaba esingenazingcingo sinokusetyenziswa kumanqanaba ombane!
I-GDHX-9500 i-wireless high voltage phase phase detector
Indlela yokuvavanya isikhangeli senqanaba:
1. Indlela yokulinganisa yangaphakathi
a.Thatha i-X kunye ne-Y transmitter kwaye uqhagamshele intonga yokuphuma (i-eriyali eyakhelwe-ngaphakathi yokudlulisa), kwaye udibanise i-transmitter X kunye ne-transmitter hook kunye neziqeshana ezimbini ezincinci ekupheleni komgca wovavanyo obonelelwe sisixhobo.Emva kokuba esinye isiphelo sifakwe kumbane we-220V (kuba i-220V yesigaba esisodwa socingo oluphilayo lutshintshwa lube lucingo oluphindwe kabini, i-voltage iphantsi), vula umbane wombane wommkeli.Emva kokuba i-waveform ibonakala, isixhobo sinokuthathwa njengesiqhelo.
2. Ukusetyenziswa kwisiza
a.Ngaphambi kokusetyenziswa, iimfuno zomsebenzi "zeMithetho yoVavanyo loKhuseleko lweZixhobo zoKhuseleko zoMbane" kufuneka zilandelwe.
b.Qhagamshela i-X kunye ne-Y transmitter kwi-insulating rods ngokulandelanayo (ubude bokwandiswa kweentonga zokukhusela kuxhomekeke kumbane)
c.Vula iswitshi yamandla yomamkeli, kwaye umamkeli uya kulandelela ngokuzenzekelayo kwaye abonise iijika ze-waveform zezigaba ze-X kunye ne-Y.Bonisa umahluko wesigaba phakathi kwezigaba ze-X kunye ne-Y.(≤± ii-20 degrees zikwisigaba,> i-20 degrees ziphuma kwisigaba) kwaye zibonisa isigaba okanye ngaphandle kwesigaba.
Ukulumkela
1. Imisebenzi ye-on-site kufuneka ihambelane neemfuno zomsebenzi ze-"Power Safety Tool Pre-Test Regulations"
2. Gwema ukusebenzisa ii-radio transmitters (walkie-talkies, njl.) ngexesha elifanayo ngexesha lokusetyenziswa, ukuze ungaphazamisi umamkeli.