Iziguquli zovavanyo lohlobo olomileyo zixhomekeke ikakhulu kwisixhobo sokupholisa sokuhambisa umoya.Ke ngoko, inomsebenzi olungileyo wokuphelisa ubushushu kunye nokusetyenziswa okugqwesileyo kokusingqongileyo.Ke ngoko, iziguquli ezilula zohlobo olomileyo zingeniswa kuzo zonke iikona zobomi babantu ngeenzuzo zabo ezizodwa.Ke, abasebenzisi banokugcina njani umgangatho ophezulu kunye nothembekileyo wohlobo loguqulo olomileyo ukuze bandise ubomi babo benkonzo?Iinkcukacha zezi zilandelayo:

GTB series dry-type test transformer
Okokuqala: nikela ingqalelo ekuhlolweni kwentsimbi
Abasebenzisi kufuneka banikele ingqalelo ekusebenziseni umoya ococekileyo oxinanisiweyo kunye neoksijini ukucoca undoqo wesixhobo, umphezulu kunye nesithuba sokulungiswa ukuze kususwe ngokufanelekileyo izinto zangaphandle kwisixhobo.Ukongeza, abasebenzisi kufuneka baqwalasele ngokucophelela i-clamps yesixhobo, nokuba iibholiti zoxinzelelo, iibholiti zokulungisa kunye nezikrufu zangaphakathi zikhululekile.Ukuba i-core kunye ne-surface coating ye-clamp yonakele, umsebenzisi kufuneka ayilungise ngepeyinti yombala ofanayo ngexesha.
Okwesibini: nikela ingqalelo ekugcinweni kwekhoyili
Abasebenzisi kufuneka banikele ingqalelo rhoqo ukujonga ukuba ukugquma okukhokelayo kohlobo loguquguquko olumelana nemozulu aluguquguqukiyo, nokuba kukho i-deformation, brittleness kunye nemigca engenalothe.Ukongeza, abasebenzisi kufuneka banikele ingqalelo ekuvavanyeni i-transformer eyomileyo kunye namalungu ashushu kakhulu, nokuba ngaba izihlanganisi ezikhokelayo zithembekile, xa umsebenzisi Kufunyaniswe ukuba i-insulation layer yecoil ikhubazekile kwaye iba brittle, kufuneka itshintshwe kwindawo yayo. ixesha
Okwesithathu: nikela ingqalelo kunxibelelwano lombane
Ngokutsho kophando, ngexesha lokusebenza kweenguqu ezinokwethenjelwa zohlobo olomileyo, abasebenzisi banoxinzelelo oluthile loqhagamshelwano kunxibelelwano lombane ukuqinisekisa ukuhanjiswa kombane kakuhle kwezixhobo.Ukongezelela, umsebenzisi kufuneka ahlolisise uxhulumaniso olusebenzayo phakathi kocingo oluphantsi lwe-low-voltage lead-out of the dry-type transformer kunye ne-busbar yokudibanisa, i-terminals high-voltage kunye ne-high-voltage cable terminals.
Ngokuqinisekileyo, ukongeza kwiingxaki ezikhankanywe ngasentla apho abasebenzisi kufuneka banikele ingqalelo xa besebenzisa i-transformers eyomileyo, abasebenzisi kufuneka bahlolisise ngenyameko ukuba ngaba bonke abalandeli abaxhobileyo banokuvulwa kwaye bacinywe ngaxeshanye.Ngaphezu koko, i-transformer ekhuthazwa ngumenzi we-reactor ayikwazi ukuhlukaniswa ixesha elide ukusuka kwimveliso ukuya ekusebenzeni, ukwenzela ukuba ugweme umphumo wezixhobo zokugquma kunye nokusetyenziswa okulandelayo.