I-GDPD-414 i-Portable Discharge Detector

I-GDPD-414 i-Portable Discharge Detector

Ingcaciso emfutshane:

I-GDPD-414 Portable Partial Discharge Detector isebenzisa inkqubo yokuvavanya amandla akrelekrele eSmart Quick, kwaye sisixhobo esiphathwayo sokuhlola ukukhutshwa kwasekhaya kwisixhobo sokufakelwa kwamandla ombane aphezulu.

 

 

 


Iinkcukacha zeMveliso

Iithegi zeMveliso

GDPD-414 Portable Partial Discharge Detector01
GDPD-414 Portable Partial Discharge Detector02
GDPD-414 Portable Partial Discharge Detector03

Engundoqo
iyunithi

UHF sensor,
uhlobo olungqukuva,ilungele iGIS

Inzwa ye-UHF, uhlobo loxande, olulungele intambo yamandla, i-transformer, i-switchgear

GDPD-414 Portable Partial Discharge Detector04
GDPD-414 Portable Partial Discharge Detector05
GDPD-414 Portable Partial Discharge Detector06

I-HFCT, ilungele intambo yamandla, i-transformer

Isivamvo se-TEV,
ifanelekile kwisixhobo sokutshintsha

Inzwa ye-ultrasonic, ifanelekile kwi-transformers, i-switchgear

GDPD-414

Imifanekiso engasentla yenzelwe ireferensi kuphela kuqala.

I-GDPD-414 ephathekayo (i-GDPD-414H ephathwayo) I-Discharge Detector ye-partial Discharge yamkela inkqubo yokuvavanya amandla ahlakaniphile ahlakaniphile (i-Soft No. 1010215, inombolo yokubhalisa uphawu lwentengiso 14684781 (14684481)).Iyakwazi ukuqwalasela ngokuguquguqukayo abenzi boluvo abahlukeneyo ngokweemveliso ezahlukeneyo eziza kuvavanywa.I-TEV, i-ultrasonic kunye ne-HFCT ifanelekile ukufunyanwa kwe-partial discharge ye-high-voltage switchgear kunye nekhabhinethi yenethiwekhi;I-Ultrasonic kunye ne-UHF zifanelekile ukufumanisa i-GIS;I-Ultrasonic kunye ne-HFCT zifanelekile ukuvavanya intambo yamandla.Inkqubo yokuxilongwa kweengcali ezakhelwe ngaphakathi inokuhlalutya idatha yokuvavanya kwaye igwebe amandla okukhutshwa kunye neengxenye ezinokwenzeka.Isetyenziswa kakhulu kumandla ombane nakuloliwe.

GDPD-414 Portable Partial Discharge Detector07

I-Ultrasonic kunye ne-TEV sensor (2-in-1)

Iimbonakalo

Yamkela ibhodi yesampula ephezulu ye-DSP/FPGA, i-4-channel synchronous data acquisition.
Inkqubo yeSoftware: isoftware yohlalutyo esekwe kwinkqubo efakwe kwi-ARM
Iitshaneli ze-6/8/16 zinokumiselwa
8.1 intshi tablet okanye Thinkpad notebook njengokuzikhethela
Iitshaneli ze-6/8/16 zinokucwangciswa ngokweemfuno ezahlukeneyo zomthengi.
Ingabonisa iimephu ze-PRPS kunye ne-PRPD, i-ellipse diagrams, i-discharge rate iimephu, iimephu ze-QT, iimephu ze-NT, iimephu ze-PRPD eziqokelelweyo, iimephu ze-fai-QN zesiteshi ngasinye somqondiso.
 Iimowudi ezinemibala emithathu ebomvu, etyheli kunye nebhlowu zibonisa ubungqongqo bokukhutshwa okungaphelelanga.

 

Umthengi unokukhetha abenzi boluvo ngokwezinto ezahlukeneyo ezivavanyiweyo:

Izivamvo

TEV/AE/HFCT

AE/UHF

AE/HFCT

 

Izinto ezivavanyiweyo

I-HV Swichgear kunye nekhabhathi yenethiwekhi yeRingi

 

IGIS

 

Intambo

 

 

I-GDPD-414 / GDPD-414H Iinkcukacha
Umamkeli wokufumana umqondiso wePD
CPU Ukusebenza rhoqo 1.2GHz / 800MHz
Inkqubo yokwenza Indlela yokusebenza efakwe kwiLinx
Izibuko zenethiwekhi enentambo LAN network port
Wireless network port I-WiFi eyakhelwe-ngaphakathi (ukhetho)
Inkqubo eqhuba imemori 1G / 512M
Imemori yokugcina inkqubo 512M / 256M
Ukufunyanwa kwedatha rhoqo 250MHz / 80MHz
Ijelo lokufumanisa i-ultrasonic
Uluhlu lomlinganiselo 0-60mV
Uluhlu lokufunyanwa rhoqo 20-200kHz
Ijelo lokufumanisa i-UHF
Ukufunyanwa rhoqo 300 ~ 1800MHz / 300 ~ 1500MHz
Uluhlu lomlinganiselo -80~10dBm
Impazamo ±1dBm
Isigqibo 1dBm
Ijelo lokufumanisa i-HFCT
Uluhlu lokuphindaphinda 0.5 ~ 100MHz
Impazamo ±1dB
Uluhlu olunamandla 60dB
Uluhlu lomlinganiselo 0-100mV
Ukuchaneka 1dB
Ijelo lokufumanisa i-TEV
Uluhlu lokuphindaphinda 3-100MHz
Impazamo ± 1dB / mV
Uvakalelo 0.01mV
Uluhlu lomlinganiselo 0-60dB / mV
Isigqibo 1dBm / mV
Ibhetri
Ibhetri eyakhelwe-ngaphakathi Ibhetri yeLithium, 12V, 4400mAh / ibhetri yeLithium, 12V, 2000mAh
Sebenzisa ixesha malunga 8 iiyure / malunga 6 iiyure
Ixesha lokutshaja Malunga neeyure ezi-2
Ukukhuselwa kwebhetri I-Over-voltage kunye nokhuseleko lwangoku
Ukutshaja ibhetri
Umbane olinganisiweyo 12.6V
Ukutshaja imveliso yangoku 2A
Ubushushu bokusebenza -20℃-60℃
Ukufuma okusebenzayo <80%
I-GDPD-414H Itheminali yomboniso ophathwa ngesandla (ibakala loshishino)
ICPU Intel Quad Core Atom Z3735F
GPU I-Intel HD Graphic (Gen7)
Flash 32GB
i-RAM 2GB
Inkqubo yokwenza Windows10
Bonisa 8.1 intshi 1280×800 IPS isikrini
Ujongano lwenethiwekhi Wifi kunye neBluetooth
Ibhetri 3.7V 8500mAH ipolymer lithium ion ibhetri
ILaptop yeThinkpad okanye iPC yeCwecwe
Ubungakanani
Ubungakanani bemeko yesincedisi / ubungakanani bokufunyanwa kwePD 395mm*295mm*105mm / 240mm*165mm*55mm
PD ubunzima bokusingatha 3kg / 0.65kg
PD ubungakanani bombhobho icala / Bonisa ubungakanani tablet terminal 570mm*360mm*240mm / 395mm*295mm*105mm
Bonisa ubunzima betheminali yethebhulethi 0.85kg
Ubungakanani bebhokisi bubonke 570mm*360mm*240mm
Indawo yokusebenza
Ubushushu bokusebenza -20℃~50℃
Ukufuma okusingqongileyo 0~90%RH
Inqanaba le-IP 54

I-GDPD-414H Isixhobo esiphathwa ngesandla sokukhupha inxalenye

GDPD-414H-Handheld-Partial-Discharge-Detector1
GDPD-414H-Handheld-Partial-Discharge-Detector01
GDPD-414H-Handheld-Partial-Discharge-Detector
GDPD-414H-Handheld-Partial-Discharge-Detector2
GDPD-414H Handheld Partial Discharge Detector5
GDPD-414H Handheld Partial Discharge Detector4