Ukukhutshwa ngokuyinxenye kwiNkqubo yokuJonga kwi-Intanethi yeeJenereyitha
Ngokuqhelekileyo, ukukhutshwa kwenxalenye kwenzeka kwindawo apho iipropati zezinto ze-dielectric azifani.Kwezi ndawo, amandla ombane wendawo aphuculwe, kwaye amandla ombane wendawo akhulu kakhulu, okukhokelela ekuqhekekeni kwendawo.Oku kuqhekeka ngokuyinxenye ayikokuwohloka ngokupheleleyo kwesakhiwo sokugquma.Ukukhutshwa okungaphelelanga ngokuqhelekileyo kufuna umlinganiselo othile wesithuba serhasi ukuze siphuhle, esifana nerhasi engaphakathi kwindawo yokugquma, iiconductors ezikufutshane, okanye ujongano lokhuselo.
Xa amandla entsimi yendawo edlula amandla e-dielectric ezinto zokugquma, ukukhutshwa okuyingxenye kwenzeka, okubangela ukuba iipulse ezininzi zokukhupha zenzeke ngexesha lomjikelo omnye wokusebenzisa i-voltage.
Ubungakanani bokukhutshwa okunikezelweyo buhambelana ngokusondeleyo neempawu ezingaqhelekanga kunye neempawu ezithile ze-dielectric zezinto eziphathekayo.
Ukukhutshwa okubonakalayo okubalulekileyo kwi-motor kudla ngokuba luphawu lwe-insulation defects, njengomgangatho wokuvelisa okanye ukuthotywa kwe-post-run degradation, kodwa oku akusona isizathu esithe ngqo sokungaphumeleli.Nangona kunjalo, ukukhutshwa kwenxalenye kwi-motor nako kunokonakalisa ngokuthe ngqo i-insulation kwaye kuchaphazele inkqubo yokuguga.
Imilinganiselo ethile yokukhupha kunye nokuhlalutya inokusetyenziswa ngokufanelekileyo kulawulo lomgangatho we-windings emitsha kunye namacandelo ajikelezayo kunye nokubonwa kwangaphambili kweziphene zokugquma ezibangelwa yimiba efana ne-thermal, umbane, indalo kunye noxinzelelo lomatshini ekusebenzeni, okunokukhokelela ekungaphumeleli kokugquma.
Ngenxa yobuchwephesha bemveliso ethile, iziphene zokuvelisa, ukuguga okuqhelekileyo okanye ukuguga okungaqhelekanga, ukukhutshwa okungaphelelanga kunokuchaphazela ulwakhiwo lwe-insulation yalo lonke i-stator winding.Uyilo lwemoto, iimpawu zezixhobo zokugquma, iindlela zokuvelisa, kunye neemeko zokusebenza zichaphazela kakhulu inani, indawo, indalo, kunye nentsingiselo yophuhliso lokukhutshwa kwenxalenye.Kwiimeko ezininzi, ngeempawu zokukhutshwa ngokuyinxenye, imithombo eyahlukeneyo yokukhutshwa kwendawo inokuchongwa kwaye yahlulwe.Ngokusebenzisa intsingiselo yophuhliso kunye neeparamitha ezinxulumeneyo, ukugweba imeko yokugquma kwenkqubo, kunye nokubonelela ngesiseko sangaphambili solondolozo.
Ipharamitha yophawu lokukhutshwa kwenxalenye
1. Intlawulo yokukhupha ebonakalayo q(pc).qa=Cb/(Cb+Cc), isixa-mali sokukhupha siboniswa ngokubanzi ngentlawulo ebonakala isenzeka rhoqo qa.
Ukuquka i-Cc sisiphene esilingana nesakhono
2. Isigaba sokukhupha φ (izidanga)
3. Ukukhutshwa kwereyithi yokuphindaphinda
Iqonga lesoftware
PD umqokeleli
I-sensor yokukhupha inxalenye ye-6pcs
Ikhabhinethi yokulawula (ukubeka ikhompyuter yeshishini kunye nokubeka iliso, ingcebiso ebonelelwe ngumthengi)
1. Isivamvo somqondiso wokukhupha inxalenye
I-sensor ye-HFCT yokukhupha inxalenye iqukethe i-core magnetic, i-coil ye-Rogowski, iyunithi yokucoca kunye nesampuli, kunye nebhokisi yokukhusela i-electromagnetic.Ikhoyili inxeba kwi-core magnetic kunye ne-high magnetic permeability kwi-frequency ephezulu;Uyilo lweyunithi yokuhluza kunye nesampulu ithathela ingqalelo iimfuno zobuntununtunu bomlinganiselo kunye nebhendi yefrikhwensi yempendulo yomqondiso.Ukuze uthintele ukuphazamiseka, uphucule umlinganiselo we-signal-to-noise, kwaye uqwalasele iimfuno zokungabikho kwemvula kunye ne-dustproof, ii-coil ze-Rogowski kunye neeyunithi zeesampuli zeefayili zifakwe kwibhokisi yokukhusela isinyithi.Icala lekhuselo liyilwe kunye ne-self-locking buckle enokuthi ivulwe ngokucinezela ukunyusa ukuqinisekisa ukulungeleka kokufakwa kwenzwa kunye nokhuseleko ngexesha lokusebenza.Inzwa ye-HFCT isetyenziselwa ukulinganisa i-insulation yePD kwi-stator windings.
I-epoxy mica HV coupling capacitor inomthamo we-80 PF.Ukulinganisa i-coupling capacitors kufuneka ibe nokuzinza okuphezulu kunye nokuzinza kwe-insulation, ngakumbi i-pulse overvoltage.Iinzwa zePD kunye nezinye izinzwa zinokudityaniswa kumamkeli wePD.I-bandwidth ebanzi ye-HFCT ikwabizwa ngokuba yi-"RFCT" yokunciphisa ingxolo.Ngokuqhelekileyo, ezi nzwakazi zixhonywe kwintambo yamandla ephantsi.
Imodyuli yesimo somqondiso yakhiwe kwi-PD sensors.Imodyuli ikakhulu ikhulisa, izihluzi, kwaye ibone umqondiso odityaniswe nenzwa, ukwenzela ukuba umqondiso we-high-frequency pulse uqokelelwe ngokufanelekileyo yimodyuli yokufumana idatha.
Iinkcukacha ze-HFCT
Uluhlu lokuphindaphinda | 0.3MHz ~ 200MHz |
I-impedance yokudlulisa | Igalelo 1mA, Imveliso ≥15mV |
Ubushushu bokusebenza | -45℃ ~ +80℃ |
Ubushushu bokugcina | -55℃ ~ +90℃ |
Idayamitha yomngxuma | φ54(yenzelwe) |
Itheminali yemveliso | N-50 isiseko |
Uphawu lwe-Amplitude-frequency ye-HFCT
2. Iyunithi yokubona iPD kwi-intanethi (umqokeleli wePD)
Iyunithi yokufumanisa ukukhutshwa kwenxalenye yeyona nto ibalulekileyo yenkqubo.Imisebenzi yayo ibandakanya ukufunyanwa kwedatha, ukugcinwa kwedatha kunye nokucubungula, kwaye ikwazi ukuqhuba i-fiber optical LAN okanye ukudlulisa idatha nge-WIFI kunye ne-4G iindlela zokunxibelelana ezingenazintambo.Umqondiso wokukhupha inxalenye kunye nomqondiso wangoku wokumisa weeseti ezininzi zamalungu (oko kukuthi i-ABC yesigaba sesithathu) inokufakwa kwi-terminal cabinet kufuphi nendawo yokulinganisa okanye kwibhokisi yetheminali yangaphandle ezixhasayo.Ngenxa yokusingqongileyo okunzima, ibhokisi engenamanzi iyafuneka.I-casing yangaphandle yesixhobo sokuvavanya yenziwe ngentsimbi engenasici, elungele ukukhusela i-frequency ephezulu kunye nokuphindaphinda kwamandla.Ekubeni kufakwe ngaphandle, kufuneka kufakwe kwikhabhinethi engangeni manzi, ukulinganiswa kwamanzi yi-IP68, kunye nomgangatho wokushisa osebenzayo -45 ° C ukuya ku-75 ° C.
Ulwakhiwo lwangaphakathi lweyunithi yokukhangela kwi-intanethi
Iiparamitha kunye nemisebenzi yeyunithi yokukhangela kwi-intanethi
Iyakwazi ukubona iiparitha ezisisiseko zokukhutshwa njengexabiso lokukhupha, isigaba sokukhupha, inombolo yokukhupha, njl., Kwaye inokubonelela ngezibalo kwiiparitha ezifanelekileyo ngokweemfuno zabathengi.
Umlinganiselo wesampulu ye-partial discharge pulse signal ayikho ngaphantsi kwe-100 MS / s.
Ubuncinci bokukhutshwa okulinganiselweyo: 5pC;ibhendi yokulinganisa: 500kHz-30MHz;ukukhupha isisombululo se-pulse: 10μs;isisombululo sesigaba: 0.18 °.
Iyakwazi ukubonisa umzobo wokukhupha umjikelezo wamandla, i-dimensional-dimensional (Q-φ, N-φ, NQ) kunye ne-dimensional-dimensional (NQ-φ) yokukhupha i-spectra.
Inokurekhoda iiparamitha ezifanelekileyo ezifana nokulandelelana kwesigaba sokulinganisa, isixa sokukhupha, isigaba sokukhupha kunye nexesha lokulinganisa.Inokubonelela ngegrafu yendlela yokukhupha kwaye inesilumkiso sangaphambili kunye nemisebenzi ye-alam.Inokubuza, icime, ikhuphele kwaye iprinte iingxelo kwisiseko sedatha.
Inkqubo ibandakanya oku kulandelayo kumxholo wokufumana umqondiso kunye nokusetyenzwa: ukufumana umqondiso kunye nokuhanjiswa, ukutsalwa kweempawu zesignali, ukuqaphela ipateni, ukuxilongwa kwephutha kunye nokuhlolwa kwesimo sezixhobo zentambo.
Inkqubo inokubonelela ngesigaba kunye nolwazi lwe-amplitude yesignali yePD kunye nolwazi loxinaniso lwe-pulse yokukhupha, oluncedo ukugweba uhlobo kunye nobukhulu bokukhutshwa.
Ukukhetha imo yonxibelelwano: intambo yenkxaso yenethiwekhi, i-fiber optic, i-wifi yokuzilungiselela i-LAN.
3. Inkqubo yesoftware yePD
Inkqubo isebenzisa isoftware yokumisela njengeqonga lophuhliso lokufumana kunye nokuhlalutya isoftware ukuqinisekisa ukuphunyezwa kakuhle kobuchwephesha bokuchasana nokuphazamiseka.I-software yenkqubo inokwahlulwa ibe yiparameter setting, ukufumana idatha, ukusetyenzwa kwe-anti-interference, uhlalutyo lwe-spectrum, uhlalutyo lwentsingiselo, ukudibanisa idatha kunye nokunika ingxelo.
Phakathi kwazo, inxalenye yokufunyanwa kwedatha igqibezela ubukhulu becala ukusetwa kwekhadi lokufunyanwa kwedatha, njengethuba lesampulu, eyona ndawo iphezulu yomjikelo, kunye nekhefu lesampulu.I-software yokufumana iqokelela idatha ngokweeparamitha zekhadi lokufumana isethi, kwaye ithumela ngokuzenzekelayo idatha eqokelelweyo kwi-software echasene nokuphazamiseka ukuze iqhutywe.Ngaphandle kwenxalenye ye-anti-interference processing part, eyenziwa ngasemva kweprogram, enye iboniswa nge-interface.
Iimpawu zenkqubo yesoftware
Ujongano oluphambili lukhuthaza ulwazi olubalulekileyo lokubeka iliso kwaye ucofe i-prompt ehambelanayo ukufumana ngokuthe ngqo ulwazi oluneenkcukacha.
I-interface yokusebenza ilungele ukusetyenziswa kunye nokuphucula ukusebenza kakuhle kokufunyanwa kolwazi.
Ngomsebenzi wokukhangela wedatha onamandla wombuzo wefomu, igrafu yentsingiselo kunye nohlalutyo lwesilumkiso sangaphambili, uhlalutyo lwe-spectrum, njl.
Ngomsebenzi wokuqokelela idatha kwi-intanethi, onokuskena idatha yenkqubo engaphantsi nganye kwisikhululo ngexesha lekhefu elibekwe ngumsebenzisi.
Ngomsebenzi wesilumkiso sesiphoso sezixhobo, xa ixabiso elilinganisiweyo lento yokukhangela i-intanethi idlula umda we-alamu, inkqubo iya kuthumela umyalezo we-alamu ukukhumbuza umqhubi ukuba aphathe izixhobo ngokufanelekileyo.
Inkqubo inomsebenzi opheleleyo kunye nokugcina umsebenzi, onokugcina ngokufanelekileyo idatha yenkqubo, iiparitha zenkqubo, kunye neelogi zokusebenza.
Inkqubo ine-scalability eyomeleleyo, enokuqonda ngokulula ukongezwa kwezinto zokubona imeko yezixhobo ezahlukeneyo, kwaye ilungelelanise nokwandiswa komthamo weshishini kunye neenkqubo zoshishino; Ngomsebenzi wolawulo lwelog, erekhoda iilogi zokusebenza komsebenzisi kunye neelogi zolawulo lonxibelelwano lwenkqubo ngokweenkcukacha, enokubuzwa ngokulula okanye uzigcine.
4. Ikhabhinethi yokulawula
Ikhabhinethi yolawulo ibeka iliso kunye nekhompyuter yeshishini, okanye ezinye izixhobo eziyimfuneko.Kungcono ukunikezelwa ngokusetyenziswa
Ikhabhinethi ifakwe ngokusisigxina kwigumbi lokulawula eliphambili lesikhululo, kwaye ezinye iindawo zingakhethwa ukufakwa ngokweemfuno zesayithi.
1. Imisebenzi
Inzwa ye-HFCT isetyenziselwa ukulinganisa i-insulation yePD kwi-stator windings.I-epoxy mica HV coupling capacitor yi-80pF.Ukulinganisa i-coupling capacitors kufuneka ibe nokuzinza okuphezulu kunye nokuzinza kwe-insulation, ngakumbi i-pulse overvoltage.Iinzwa zePD kunye nezinye izinzwa zinokudityaniswa kumqokeleli wePD.I-Wideband HFCT isetyenziselwa ukuthomalalisa ingxolo.Ngokuqhelekileyo, ezi nzwakazi zixhonywe kwintambo yamandla ephantsi.
Owona mba unzima womlinganiselo wePD kukucinezelwa kwengxolo kwizixhobo zombane ophezulu, ngakumbi umlinganiselo we-HF pulse kuba unengxolo eninzi.Eyona ndlela isebenzayo yokuthomalalisa ingxolo yindlela "yexesha lokufika", esekelwe ekubhaqweni nasekuhlalutyeni umahluko kumaxesha okufika kwe-pulse ye-sensor ezininzi ukusuka kwiPD enye ukuya kwinkqubo yokubeka iliso.I-sensor iya kufakwa kufuphi nendawo yokukhupha i-insulated apho i-pulses yangaphambili ephezulu yokukhupha ilinganiswa.Isikhundla se-insulation defect sinokubonwa ngumahluko kwixesha lokufika kwe-pulse.
Iinkcukacha zomqokeleli wePD
●Ijelo lePD: 6-16.
●Uluhlu lwe-Pulse frequency (MHz): 0.5 ~ 15.0.
●PD pulse amplitude (pc) 10 ~ 100,000.
●Eyakhelwe-ngaphakathi inkqubo ingcaphephe PD-Expert.
●Ujongano: Ethernet, RS-485.
●Amandla ombane ombane: 100 ~ 240 VAC, 50 / 60Hz.
●Ubungakanani (mm): 220*180*70.
●Ngobuchule obunamandla bokuchasana nokuphazamiseka.Inkqubo isebenzisa itekhnoloji yokufumanisa i-broadband kwaye inomjikelezo ogcweleyo wokukhusela ujongano ukuze ixhathise ngokufanelekileyo ukunyuka okukhulu kwangoku kunye nokusetyenziswa kwamandla aphantsi.
●Ngomsebenzi wokurekhoda, gcina idatha yovavanyo yoqobo, kunye nedatha yoqobo xa imeko yovavanyo ingadlalwa emva.
●Ngokweemeko zentsimi, i-fiber optical LAN transmission network ingasetyenziswa, kwaye umgama wokuhambisa ude, uzinzile kwaye unokwethenjelwa.Isakhiwo sihlangene, kulula ukuyifaka, kwaye sinokuqondwa ngesakhiwo se-fiber-optic LAN.
●Isoftware yoqwalaselo isetyenziselwa ukuququzelela ujongano loqwalaselo kwindawo.
2. Umgangatho osetyenziswayo
●I-IEC 61969-2-1: I-2000 Izakhiwo zoomatshini zezixhobo zombane Ukufakwa ngaphandle kwecandelo le-2-1.
●I-IEC 60270-2000 Umlinganiselo wokukhutshwa ngokuyinxalenye.
●I-GB/T 19862-2005 I-industrial automation instrumentation resistance resistance, amandla okugquma iimfuno zobugcisa kunye neendlela zokuvavanya.
●I-IEC 60060-1 Itekhnoloji yovavanyo lombane ophakamileyo Icandelo 1: Iinkcazo ngokubanzi kunye neemfuno zovavanyo.
●I-IEC60060-2 Itekhnoloji yovavanyo lombane ophakamileyo Icandelo 2: Iinkqubo zokulinganisa.
●I-GB 4943-1995 Ukhuseleko lwezixhobo zobuchwepheshe bolwazi (kubandakanywa nezixhobo zemicimbi yombane).
●I-GB / T 7354-2003 Umlinganiselo wokukhupha inxalenye.
●I-DL/T417-2006 Izikhokelo zeSiza zoMlinganiso wokuPhuma ngokuNgakumbi weZixhobo zoMbane.
●I-GB 50217-2007 iNgcaciso yoYilo lweCable yobunjineli baMandla.