I-GDWG-III SF6 iGas Leakage Detector
I-GDWG-III SF6Isixhobo sokubona ukuvuza kwegesi, esinobuchwepheshe be-infrared (NDIR) engasasazwanga, sisetyenziswa ikakhulu ukukhomba nokulinganisa ukuvuza kwe-SF6 kwi-GIS kunye nezixhobo zokuzalisa kwakhona kwishishini lamandla.
Umyinge wokuvuza wonyaka wezixhobo zombane zegesi ye-SF6 ulinganiswa ngendlela yokubopha.Kwangaxeshanye, isixhobo sisetyenziswa ngokubanzi kwiofisi yobonelelo lwamandla, izitishi, inkampani yokutshintsha amandla ombane aphezulu, ihood yelabhoratri kunye novavanyo lwesayensi.
●Isixhobo sokutshintsha amandla ombane aphezulu
●I-helicopter ye-rotor blades
●Inkqubo yokuhanjiswa kwegesi
●Into yokucima umlilo
●Uphononongo lwezinga lokungena komoya
●Impahla Eyingozi
●Itanki
●Akukho mngcipheko we-radioactive.
●Akukho mfuneko yokutshintsha igesi ye-argon ecocekileyo rhoqo.
●Akukho mfuneko yokutshintsha inzwa rhoqo, indleko-esebenzayo.
●Akukho mfuneko yokwenza ulungelelwaniso lomgca rhoqo ngonyaka, akukho malungu okunxiba.
●Akwenziwa bubumanzi, ungcoliseko lokusingqongileyo okanye ukukhukuliseka kwedatha.
●Xa kukho ukuvuza okukhulu okanye i-SF6I-gas concentration ifikelela kwi-100%, ayiyi kungcoliswa okanye yonakaliswe.
●Ukulinganisa i-SF6ukuvuza kwerhasi ngokomgangatho nangokobungakanani.Uvakalelo kwi-SF6 yerhasi 3g/ngonyaka.
●Ukufumana i-SF6indawo yokuvuza kwegesi.
●Iiparamitha ezifana neSF6Uxinzelelo lwegesi, ubushushu, ukufuma, isalathisi samandla, umhla kunye nesimo sempompo ye-diaphragm iyaboniswa.
●Umsebenzisi-friendly interface.
●Sebenzisa iteknoloji ye-NDIR kunye ne-sensor ephezulu evela eJamani.
●Isantya sovavanyo olukhawulezayo kunye nokuphindaphindwa okuhle, idatha izinzile ngaphakathi kwe-10s.
●Ngembuyekezo yobushushu kunye noxinzelelo.
●Akukho alarm yobuxoki, akukho gesi ngaphandle SF6iimpendulo.
●Umlinganiselo werhasi ongaqhagamshelwani nawo uqinisekisa ukuba isivamvo asiyi kutyhefa nakweliphi na izinga loxinzelelo.
●Igumbi le-Thermostatic liqinisekisa ukuba akukho kukhukuliseka kweqondo lokushisa kwiqondo lobushushu le-ambient.
●Isiboniso se-OLED esiyi-3.5inch, sifundeka kukukhanya kwelanga okunamandla.
●Ibhetri ye-lithium eyakhelwe-ngaphakathi, ixesha lokulinda lide.
●Imibhobho ilungiselelwe ngokwesicelo.
●Iisampulu zokufunxa impompo ziqinisekisa ukutywinwa kakuhle kwendlela yegesi phantsi kovavanyo.
●Amaqela angaphezu kwe-100 edatha yovavanyo agcinwe ngokusekwe kugxininiso lwegesi kunye nexesha lovavanyo, kulula ukubuza.
●I-casing yangaphandle inamandla amakhulu, ikhuseleke ngokupheleleyo, i-ultra-lightweight ABS isakhiwo sezinto.
●Umgaqo wokulinganisa: Inzwa ye-infrared engeyiyo i-dispersive (NDIR)
●Uluhlu lokulinganisa: 0-2000ppmv SF6
●Isisombululo: 0.1ppmv
●Ukuchaneka: ±2%FS
Nokuba uluhlu lokulinganisa lungaphezulu kwe-5000ppm, isixhobo asiyi konakala.
●Imposiso yokuphinda: ≤±1%
●Uvakalelo: 1ppmv
●Ixesha lokuphendula: ≤10s
●Ixesha lokubuyisela: ≤15s
●Uzinzo: ≤±20ppm, ngaphezu kwe-1000hours
●Imo yesampula: uhlobo lokufunxa impompo, ukuhamba ukuya kuthi ga kwi-1L / min.
●Uziro shift: ≤±1%(FS/nyaka)
●Imposiso yomgca: ≤±1%
●Incopho yangoku: <700mA
●Amandla aphakathi: <2W.
●Ukusebenza koxinzelelo lomoya: 800-1150hPa.
●Ukufuma kokusingqongileyo: 0-95%RH
●Ubushushu bokugcina: -20~+60℃
●Ubushushu bokusebenza: -20°+50℃
●Umsebenzi wokufuma: 0-95%(akucondensing)
●I-voltage esebenzayo: 220VAC ± 10%, 50Hz Okanye i-Li-ibhetri eyakhelweyo, i-6hours eqhubekayo yokusebenza emva kwentlawulo epheleleyo.
●Ubungakanani: 220×250×120mm
●Ubunzima: malunga ne-2kg
Iyunithi ephambili | Iseti e-1 |
Itshaja | Iqhekeza eli-1 |
Ukubanjwa ngesandlaphonononga | Iqhekeza eli-1 |
I-Anti-slip ibhanti | Iqhekeza eli-1 |
Hmalunga ne600mm | Iqhekeza eli-1 |
Umsebenzisi's isikhokelo | Ikopi enye |
Wikhadi le-arranty | Ikopi enye |