I-GDSF-311WPD 3-In-1 SF6 Uhlalutyo lwegesi
I-GDSF-311WPD (GDSF-411WPD) sisixhobo esifanelekileyo xa kuyimfuneko ukuvavanya umxholo wamanzi, ukucoceka kunye nokubola kweemveliso zegesi ye-SF6.Inxalenye ephambili yovavanyo lwendawo yombethe yi-DRYCAP® i-sensors series eziveliswe yinkampani yaseFinland Vaisala.Umgaqo we-infrared i-SF6 yokuvavanya ukucoceka kwegesi eyenziwe yiNkampani yoVavanyo yaseYurophu isetyenziselwa ukuvavanya ukucoceka kwegesi ye-SF6.Inzwa ye-electrochemical eyenziwe yiNkampani ye-Mombabo eSwitzerland isetyenziswa njengesixhobo sokuvavanya imveliso ye-SF6 yokubola kwegesi.Ngeetshiphusi zehardware yobuchwephesha kunye ne-algorithms yesoftware egqwesileyo ye-STMicroelectronics, sivelise isizukulwana esitsha se-3-in-1 yomhlalutyi wegesi.
SF6Ukufuma
●Indlela yokulinganisa: Umgaqo womlinganiselo wokuchasa kunye neCapacitive
●Uluhlu lomlinganiselo: indawo yombethe -80℃--+20℃(inkxaso ppmv)
●Ukuchaneka: ±1℃
(Xa iqondo lobushushu lombethe lingaphantsi kwe-0 ℃, isiphumo senzwa yindawo yeqabaka)
●Ixesha lokuphendula: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Isisombululo: 0.01℃
●Ukuphindaphinda: ± 0.5 ℃
●Iyunithi yokubonisa: ℃, ppm, ℃P20(ixabiso eliguquliweyo ku-20℃)
●Ukuhamba kwegesi: 400-600ml / min
●Umboniso oqukuqelayo: 0-1000mL imitha yokuhamba ngedijithali
●Isampuli yoxinzelelo lwegesi: ≤1MPa
SF6Ubunyulu
●Indlela yokulinganisa: Umgaqo womlinganiselo we-infrared (NDIR series sensors)
●Uluhlu lokulinganisa: 0 ~ 100% SF6
●Ixesha lokuphendula: [90%] 60s
●Ukuchaneka: ± 0.5%FS
●Ukuphinda: ± 0.5%
●Isisombululo: 0.01%
●Iyunithi yokubonisa: %
SF6Iimveliso zokubola
●Indlela yokulinganisa: Umgaqo we-Electrochemical Measurements (i-Electrochemical series sensors)
●Uluhlu lomlinganiselo: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Ukuchaneka: H2S: 10ppmv ±3%
SO2: 10ppmv ±3%
CO: 50ppmv ±4%
HF: 10ppmv ±3%
●Ukuphindwa kwakhona: H2S: 10ppmv ±2%
SO2: 10ppmv ±2%
CO: 50ppmv ±2%
HF: 10ppmv ±2%
●Isisombululo: 0.01ppmv
●Iyunithi yokubonisa: ppmv
●Ukunikezelwa kwamandla: 220VAC ± 10%, 50Hz, ukusetyenziswa kwe-AC / DC, ukukhuselwa ngokugqithisileyo, ukusebenza okuqhubekayo akukho ngaphantsi kwe-8hours.
●Sebenzisa ubushushu bokusingqongileyo: -20-+60℃
●Ukufuma kokusingqongileyo: 90%RH
●Impembelelo yexabiso lokulinganisa: Akukho mpembelelo yoxinzelelo kunye nokuhamba
●Ubungakanani: 395 * 295 * 155mm
●Ubunzima: malunga ne-2kg.
I-GDSF-411WPD SF6Iimveliso zokubola
●Ukuchaneka: H2S: <10ppmv ± 0.3ppmv;>10ppmv ±3%
I-SO2: <10ppmv ± 0.3PPmv;>10ppmv ±3%
●Ukuphindaphinda: H2S: <10ppmv ± 0.2ppmv;>10ppmv ±2%
I-SO2: <10ppmv ± 0.2PPmv;>10ppmv ±2%
●Ukuhlaziya kunye nomsebenzi wokugcwalisa: igumbi lokuphinda lisetyenziswe 2L,ixesha lokurisayikilisha ≤ 5min
Ngomsebenzi wokomisa igesi
●Ubungakanani: 395 * 295 * 315mm
●Ubunzima: malunga ne-5kg.
UMvavanyi ongundoqo | Iqhekeza eli-1 |
Iadaptha | 1 iseti |
Umbhobho weTeflon(ubandakanya ivalve yohlengahlengiso kunye nesinxibelelanisi esikhawulezayo) | 1 iseti |
Umbhobho womsila | 1 iseti |
Iphathi ezisecaleni | 1 iseti |
Itshaja | Iqhekeza eli-1 |
Umsebenzisi's Isikhokelo | Iqhekeza eli-1 |
Ingxelo yoVavanyo | Iqhekeza eli-1 |