GDOT-80C Insulation Oil Breakdown Tester 80kV
Kukho inani elikhulu lezixhobo zombane kwinkqubo yamandla, inkqubo kaloliwe kunye nemigodi yezityalo zepetrochemical ezinkulu kunye namashishini, ukugquma kwabo kwangaphakathi kuninzi kufakwe i-oyile.Amandla e-dielectric ye-oyile ekhuselayo luvavanyo lwesiqhelo olunyanzelekileyo.Ukuze kuhlangatyezwane neemfuno zemarike, inkampani yethu iphuhlise kwaye yavelisa uluhlu lwabavavanyi bamandla e-dielectric yeoli ye-dielectric ngokomgangatho we-IEC156 "I-oyile yokugquma i-oyile-ukuzimisela kwamandla e-dielectric" kunye nomgangatho woshishino welizwe DL-474 · 4-92DL/T596 -1996 "Ikhowudi yokuvavanya yokuthintela kwizixhobo zamandla ombane".
Esi sixhobo sithatha i-microcomputer ye-single-chip njengeyona nto ingundoqo, iqonda yonke i-automation yovavanyo, inomlinganiselo ophezulu wokuchaneka komlinganiselo, iphucula kakhulu ukusebenza kakuhle, kwaye inciphisa kakhulu amandla omsebenzi wabasebenzi.Ngexesha elifanayo, isixhobo sinembonakalo edibeneyo kwaye ikulungele ukuthwala.
●Yamkela i-microprocessor ukugqiba ngokuzenzekelayo imisebenzi yokunyusa, ukubamba, ukuvuselela, ukumisa, ukubala, ukuprinta, njl., kwaye inokwenza ukujikeleza kweoli ukumelana novavanyo lombane kuluhlu lwe-0-80 kV.
●Ikomityi yeoli yesixhobo yenziwe ngokuphoswa kweglasi ekhethekileyo ngexesha elinye, elithintela ukuphazamiseka okufana nokuvuza kweoli.
●Uyilo olulodwa oluphezulu lwesampulu yesixhobo luvumela ixabiso lokuvavanya ukuba lifake i-A / D converter ngokuthe ngqo, ukuphepha iimpazamo ezibangelwa kwisekethe ye-analog, kunye nokwenza iziphumo zokulinganisa zichaneke ngakumbi.
●Imigangatho yokwenziwa kovavanyo lwesixhobo ibandakanya imigangatho yoshishino, imigangatho yesizwe kunye nemigangatho yangaphandle, kwaye ukusebenza kulula kwaye kulula.
●Nge-over-voltage, over-current, limit and other protection ukuqinisekisa ukhuseleko lwabaqhubi.Kwaye inamandla okuchasa ukuphazamiseka kunye nokuhambelana kakuhle kwe-electromagnetic.
●Imveliso yombane: 0-80kV
●Isantya sokugqwethwa kwamandla: <1%
●Umthamo: 1.5kVA
●Ikomityi yeoli: 240ml
●Ukuchaneka komlinganiselo: ±3%
●Ukunyuka kwamandla ombaneizinga: 2kV/s, 3kV/s ukukhetha , impazamo: 0.2kV/s
●Igalelo lamandla: AC220V± 20%, 50Hz±5Hz
●Amandla: <200W
●Ubushushu bokusebenza: 0-40 ℃
●Ukufuma: <85%RH
●Ubungakanani: 430 * 350 * 370mm
Isixhobo se-GDOT-80C | Iqhekeza eli-1 |
Ikomityi yeoli(250ml) | Iqhekeza eli-1 |
Ikhodi yamandla | Iqhekeza eli-1 |
Intambo ephantsi | Iqhekeza eli-1 |
I-fuse esecaleni | 2 iqhekeza |
Ukuvuselela i-nut | 2 iqhekeza |
Umgangatho 2.5mm | Iqhekeza eli-1 |
Tweezer | Iqhekeza eli-1 |
Iphepha lokuprinta | Imiqulu eyi-1 |
Isikhokelo somsebenzisi | Ikopi enye |
Ingxelo yovavanyo lwasefektri | Ikopi enye |
Enye i-electrode inokuzikhethela