I-GDJD-3A SF6 iGas Density Relay Calibrator
I-GDJD-3A SF6 irhasi yoXinano lwe-Relay Calibrator sisilungelelaniso esizenzekelayo, esebenzisa i-microprocessor efakelweyo ukuqhubela phambili ulungelelwaniso lokusebenza kuzo zonke iintlobo ze-SF6 yogqithiso loxinzelelo lwegesi.Ikwasisixhobo esiphathwayo esinokwenza uguqulo olusemgangathweni lwe-SF6 yoxinzelelo lwerhasi kulo naliphi na iqondo lobushushu lokusingqongileyo.Esi sixhobo sisetyenziswa ikakhulu kwimveliso yegesi ye-SF6, ukugcinwa kunye nokubeka iliso kwinkqubo yamandla.
●Lungiselela ngokuzenzekelayo ukuhanjiswa koxinzelelo kunye negeyiji yoxinzelelo.
●Uyilo oludibeneyo, ubungakanani obuncinci, kunye nobunzima obulula, kulula ukuthwala.
●Umbala wesikrini se-LCD, imenyu yeWindows.
●Unikezelo lwamandla lunomsebenzi we-UPS, olungele ukusebenza kwintsimi.
●Ngomshicileli omncinci, ukuprinta iziphumo zovavanyo ngokuthe ngqo.
●Ipropathi elungileyo yokutywina, musa ukuchitha igesi ye-SF6 ngexesha lokulinganisa.
●Iziphelo ezimbini zombhobho wokudibanisa une-valve yokujonga ngokukhawuleza, ukusebenza lula kwaye ugweme ukungena kwamanzi kunye nomoya kumbhobho.Akukho sidingo sokuqhaqha uninzi lwereyiti yoxinaniso ukulinganisa ngokuthe ngqo.
●Kukho isikhuseli sombane esizenzekelayo kwindawo yesampulu.Ukuba isampulu yekliphu yekliphu ayidibanisi nombane we-220V, ayisayi kutshabalalisa isixhobo.
Umlinganiselo woxinzelelo ngokuzenzekelayo xa i-alam yoxinzelelo lwegesi ye-SF6 okanye i-disalarm kuwo nawuphi na ubushushu bokusingqongileyo.Iyakwazi ukuyiguqulela kuxinzelelo oluqhelekileyo kwi-20 ℃, ukuqonda ukulinganisa ukusebenza kwe-alarm.
Yenza umlinganiselo woxinzelelo ngokuzenzekelayo xa i-SF6 yerhasi yoxinaniso lwe-relay interlock okanye i-relive interlock kulo naliphi na iqondo lobushushu lokusingqongileyo.Iyakwazi ukuyiguqulela kuxinzelelo oluqhelekileyo kwi-20 ℃, ukuqonda ulungelelwaniso lokusebenza kwe-interlock.
Ukuba kukho igeyiji yoxinzelelo okanye imitha yoxinaniso ye-SF6 yoxinzelelo lwegesi evavanyiweyo, inokulinganisa ukuchaneka kwegeyiji yoxinzelelo okanye imitha yoxinano.
Guqula i-SF6 yoxinzelelo lwegesi kuxinzelelo oluqhelekileyo kwi-20℃.
Guqula uxinzelelo olusemgangathweni kwi-20 ℃ kuxinzelelo nakubuphi na ubushushu.
Seta imilinganiselo emininzi yereyiyi yoxinaniso olunye.Isiphumo somlinganiselo lixabiso eliphakathi.
Ubonelelo lwamandla: Ukusetyenziswa kwe-AC/DC, ibhetri eyakhelweyo etshajwayo, AC 220V±10%, 50Hz
Ukuchaneka: Iklasi 0.25
Bonisa: 3.5inch umbala lokwenyani LCD screen
Umshicileli: Umshicileli wodidi lwenaliti
Uluhlu loxinzelelo lomlinganiselo: 0-1.0Mpa
Uluhlu loxinzelelo lokulinganisa: uxinzelelo oluqhelekileyo 0-0.9Mpa kwi-20 ℃
Uluhlu lobushushu: -50℃--100℃
Ubungakanani: 258 * 240 * 88mm
Ubunzima: malunga ne-2.5kg
Isisombululo soxinzelelo: 0.0001Mpa
Isisombululo sobushushu: 0.1℃
Umthamo wokugcina: 50-100pcs
Izibuko lonxibelelwano: USB2.0