I-GDJB-6000M iSmart Substation Relay Protection Test System
I-GDJB-6000M iSmart Substation Relay Test Test System sisizukulwana esitsha somvavanyi okrelekrele okhuselweyo we-relay eyilwe ngokwe "Smart Substation Relay Protection Specifications" kunye ne "Smart Substation Technical Guidelines".Ayinakuqonda kuphela uvavanyo olupheleleyo lomsebenzi wesixhobo sokukhusela idijithali (IEC61850, isikhululo sedijithali esihlakaniphile), kodwa iphinde iqhube uvavanyo olupheleleyo lomsebenzi kwisixhobo sokukhusela esiqhelekileyo (isikhululo esiqhelekileyo).
I-GDJB-6000M yimveliso entsha ephathekayo ephuhliswe ngokuzimeleyo ngokusetyenziswa kwetekhnoloji efana neenkqubo zokusebenza zexesha langempela, iiprosesa ezisebenza ngokuphezulu, kunye nezixhobo ezinengqondo ezinkulu, ezidityaniswe neemeko zentsimi yamandla kunye namava amaninzi omsebenzisi wamandla.Isebenza ngokubanzi kumaziko ombane, izitishi, abavelisi bezixhobo, amashishini kunye namaziko, kunye namanye amaziko ophando ekufuneka enze uvavanyo lokukhuselwa okanye ukuhlolwa.
I-GDJB-6000M yamkele iskimu solawulo lobunjineli ukulawula uvavanyo;ulawulo lweprojekthi yamkela imodeli yoluhlu oluthathu lwezixhobo zokukhusela, uhlobo lokukhusela, kunye nendawo yokuvavanya ukulawula uvavanyo.Ulwakhiwo lucace kakhulu;Ixhasa imveliso yeanalog, kwaye ngaxeshanye ingaqhuba imveliso yobuninzi be analog kwaye ithumele kwaye ifumane imiyalezo ye GOOSE;Ibonelela ngeendlela ezininzi zokuqwalasela imiyalezo ye-SV kunye ne-GOOSE, kubandakanywa nezicwangciso zezandla, ukubonwa kwenethiwekhi, kunye nokungenisa iifayile ze-SCL;Umyalezo wedijithali obonakalayo unobumbeko oluguquguqukayo kakhulu lwe-transceiver, enokuthumela imiyalezo emininzi ye-SV kunye ne-GOOSE nge-1 port optical, kunye nemiyalezo efanayo ye-SV kunye ne-GOOSE inokuthunyelwa ngee-ports ezininzi ze-optical.
I-DL/T 860 Series Standard Standard "Substation Network Network and System"
I-DL/T 624-2010 "Iimeko zobuGcisa zoKhuseleko lweMicrocomputer eSekwe kwiZixhobo zoVavanyo eziSekwe kwi-Relay"
I-GBT 7261-2008 "Indlela yoVavanyo oluSiseko loKhuseleko lweRelay kunye noKhuseleko lweZixhobo ezizenzekelayo"
IEC 60255-24: 2001 "Ii-relays zombane - Icandelo 24: Ifomathi eqhelekileyo yokutshintshiselana kwedatha yesikhashana (COMTRADE) kwiinkqubo zamandla"
●Smart Test Modyuli
Ukuhlela itemplate yovavanyo olukrelekrele kuyaxhaswa.Izinto zovavanyo zinokudibaniswa ngokungenamkhethe ngexesha lenkqubo yovavanyo kwaye zigcinwe njengeefayile zeprojekthi zovavanyo eziphinda zisebenziseke ukuze kuphuculwe ukusebenza kakuhle kovavanyo kwinqanaba lokugqibela lokuhlola kunye ne-elimination.Imisebenzi yesoftware enamandla.Ixesha lokwenyani lokubonisa uhlobo lwamaza, max.Incopho kunye nendawo.Isoftware inokukhangela kwaye ihlalutye uhlobo oluthile lwamaza.IiWindows zinokusondezwa ngaphakathi nangaphandle.Idatha yecandelo elinye inokuhlalutya i-spectral kwaye umxholo we-spectrum wokukhutshwa kwe-waveform unokuhlalutywa.
●Uvavanyo oluzenzekelayo
Ngokhuseleko lwe-site kunye nokukhuselwa kwedijithali umsebenzi wokuvavanya ngokuzenzekelayo, zonke izinto zokuvavanya zesixhobo esisodwa sokukhusela zingagqitywa ngesitshixo esisodwa.Idatha yokuvavanya kunye ne-wave ekhutshwe ngokukhawuleza ingagcinwa ngokuzenzekelayo okanye ngesandla.
●Imveliso yedijithali / ye-analog
Inokuvavanya iyunithi yokudibanisa, ukhuseleko, umlinganiselo kunye nezixhobo zokulawula, kunye neetheminali ezihlakaniphile zezikhululo zedijithali, kwaye inokuvavanya izixhobo ezifana nokukhuselwa kwe-analog kunye neyunithi ye-transformer.
●Imveliso ngaxeshanye ye-analog kunye nobungakanani bedijithali
Ixhasa imveliso ye-analog ngaxeshanye kunye nokuthumela nokwamkela umyalezo we-GOOSE.
● Iimowudi zokuskena ezininzi
Ixhasa i-amplitude, isigaba, i-frequency, i-impedance, i-vector, ulandelelwano, kunye namandla enziwa ngovavanyo lwemanyuwali okanye oluzenzekelayo, lukwaxhasa uvavanyo lokutshintsha oluzenzekelayo ngokwendlela yokuhlelwa, ukutyibilika kunye nokudibanisa.
● Ukhuseleko kunye ne-alam
Ngokutshisa ngokugqithisileyo kunye nokukhuselwa kwangoku, umthombo wangoku unokhuseleko oluvulekileyo lwesiphaluka kunye nomsebenzi we-alarm, kwaye umthombo we-voltage unomthwalo ogqithisiweyo kunye nomsebenzi wokukhusela omfutshane.
● Umboniso womzobo weterminal ebonakalayo
Inkxaso ye-terminal ye-terminal ebonisa umsebenzi wokubonisa umzobo, ukuhamba kwedatha kucacile.
●Thumela kwaye ufumane imiyalezo ngexesha elinye
Inkxaso ye-IEC61850-9-1, i-IEC61850-9-2 kunye ne-GOOSE imveliso yomyalezo wedijithali obonakalayo.Isignali yeGOOSE inokuthunyelwa kwaye ifunyenwe ngokuzimeleyo, kwaye inokuthumela kwaye ifumane nge-interface ye-Ethernet ye-optical kunye ne-IEC 61850-9-2.
● FT3/Eyandisiweyo FT3
Inkxaso ye-FT3, i-FT3 eyandisiweyo kunye ne-DL / T 282 imveliso yomyalezo, kunye nenkxaso ye-2M / 4M / 6M / 8M / 10M izinga le-baud ye-UART encoding kunye ne-5M / 10M / 20M ye-encoding yaseManchester.
● Uvavanyo olungaqhelekanga
Ngomsebenzi ongaqhelekanga womyalezo we-analog, unokulinganisa ukungaqhelekanga kumgangatho, ukuthumela i-jitter frequency, ukulibaziseka okungaqhelekanga, ukulahleka kwepakethi, ngaphandle kwenyathelo, ukutsiba kwenombolo ye-serial, imowudi yokugcinwa, utshintsho lwenyani kunye nolunye uvavanyo.
● Impazamo yokudlala
Ixhasa ukulinganisa impazamo kunye nomsebenzi wokudlala idatha ye-COMTRADE.
● Inkonzo ye-MMS
Ngomsebenzi wokufunda nokubhala weMMS, unokufunda nokubhala useto olukrelekrele lwezixhobo ze-IED kunye nolunye ulwazi loqwalaselo.
● Ungqamaniso lwexesha kunye nokunika ixesha
Ngomsebenzi we-synchronous trigger, inkxaso yokufikelela ngokuthe ngqo kwi-antenna ye-GPS / BD ye-antenna yexesha, iphinde ixhase i-IRIG-B, i-PPS kunye ne-PTP 1588 imodi yexesha kwaye inokuxhasa ukuphuma kwangaphandle kwe-IRIG-B, i-PPS kunye ne-PTP 1588 ixesha lokunika uphawu.
● Uqhagamshelwano olunzima lwegalelo lokubini kunye nemveliso yokubini
Ubuninzi begalelo busebenza kunye nabafowunelwa abaguquguqukayo, kunye nohlobo lwegalelo kunye ne-voltage yegalelo zibonwa ngokuzenzekelayo.Amatshaneli ahlukanisiwe komnye nomnye, kunye ne-polarity reverse uxhumano kunye ne-alarm prompt.
●Ukufumana umyalezo kunye nohlalutyo
Ngomyalezo ofumana kunye nomsebenzi wokuhlalutya, umyalezo ofunyenweyo unokuvulwa kunye ne-ZHNPA yokuhlalutya okanye ukuthumela ngaphandle.
●Imowudi yefiber enye
I-optical port isekela ukuhanjiswa kwefayibha enye kunye nokwamkelwa kwefayibha enye kwaye ixhasa uvavanyo lwamandla okukhanya.
●Isignali encinci ye-analog
Ixhotyiswe nge-analog encinci ye-interface ye-analog, ixhasa i-12 indlela ye-analog encinci ye-input, inokulinganisa -7V ~ 7V i-voltage ye-AC, ixhasa i-12 indlela ye-analog yemveliso encinci ye-analog, kwaye inokuvelisa -7V ~ 7V i-AC voltage.
●Ukusebenza ngokuchukumisa
Ixhotyiswe nge-10.4 intshi ye-high-resolution display exhasa ukusebenza kwe-touch.
●Uqhagamshelo olungenazingcingo
Nikeza umsebenzi wovavanyo olukude, kunye nemodyuli yeWiFi, esebenziseka lula.
Imveliso yomthombo wombane we-AC | Uluhlu: 6 × 120 V, 120V / 60VA ngendlela Ukuchaneka: ± 10mV kwi-0.2 ~ 2V;± 0.2% kwi-2V ~ 120V Isisombululo: 1mV |
Imveliso yomthombo wangoku we-AC | Uluhlu: 6 × 30A, 30A / 150VA ngendlela Ukuchaneka: ± 10mA ye-0 ~ 500mA;± 0.2% ye-500mA ~ 30A Isisombululo: 1mA |
Isigaba semveliso | Uluhlu: 0 ~ 360 ° Ukuchaneka: ± 0.1 ° Isisombululo: 0.1 ° |
Imveliso rhoqo | Uluhlu: 0 ~ 1000Hz Ukuchaneka:<±0.001Hz (0~65Hz) <±0.01Hz(65~450Hz) <±0.02Hz (450~1000Hz) Isisombululo: 0.001 Hz |
Imveliso yomthombo wombane we-DC | Uluhlu: 6 indlela, indlela nganye 0 ~ 130V / 60VA Ukuchaneka: 0.2% |
Imveliso yomthombo yangoku yeDC | Uluhlu: 6 indlela, indlela nganye 0 ~ 20A/100VA Ukuchaneka: 0.2% |
Unxibelelwano lwe-IEC 61850 | Inani lamachweba: izibini ezi-6 ziyi-100M eguqukayo;Izibini ezi-2 ziyi-100/1000M ehambelanayo Uhlobo lwesiNxulumaniso: LC Ubude bobude: 1310nm |
Unxibelelwano lwe-IEC 60044 | Inani lamachweba: i-6 yokuhambisa izibuko, i-2 ifumana izibuko Uhlobo lwesiNxulumanisi: ST Ubude bobude: 850nm |
Ungqamaniso lojongano | Ubungakanani: 1 * GPS / BD ANT;2*IRIG-B/PPS isignali yokubona-Isi-1 sokubeka ixesha, isi-1 sokunikela ixesha;Izibini ezi-2* IRIG-B/PPS iimpawu zombane-Iperi e-1 yexesha, ipere e-1 yokunikela;Isibini esi-1 * IEEE 1588; Uhlobo lwe-Interface: GPS / BD ANT, IRIG-B / PPS isignali ye-optical;I-IRIG-B / PPS uphawu lombane;IEEE 1588 |
Umlinganiselo wexesha | Uluhlu: 10ms ~ 9999.999s Ukuchaneka: 1ms |
Tshintsha igalelo | Ubungakanani: 8 izibini Ukuphazamisa amandla: DC250V/0.5A |
Tshintsha imveliso | Ubungakanani: Izibini ezi-6, apho izibini ezi-2 zezokuvulwa ngokukhawuleza |
Uqhagamshelo olungenazingcingo | Uhlobo lwesiNxulumaniso: WIFI |
Uqhagamshelo lweentambo (unxibelelwano lwe-Ethernet) | Inani lamazibuko: l 2 Uhlobo lwesiNxulumanisi: 100 megabytes LAN port, RJ45 |
Ukunikezwa Amandla | Voltage: AC/DC 220V, ukutenxa okuvumelekileyo: -20% ~ 15% FUbungakanani: 47 ~ 65 Hz |
Igalelo lesiginali ye-analog encinci | Inani lamajelo: indlela ye-12; Uhlobo lwe-Interface: Iplagi ye-Aviation, i-AC Voltage |
Imveliso ye-analog encinci | Inani lamajelo: indlela ye-12; Uhlobo lwe-Interface: Iplagi ye-Aviation, i-AC Voltage |
Ujongano lwe-USB | Ubungakanani: 2 |
Iimeko zendawo yokusebenza | Ubushushu bokusebenza: -20°C~70°C Ukufuma: ≤95%, akukho condensation |
Abanye | Ubunzima: 15 kg Ubungakanani: 360×480×190(mm) Ujongano lwe-Intanethi: RJ45 Bonisa: 10.4 intshiisikrini esibanjwayo1024 * 768 umbala wokwenyani LCD ukubonisa |